What should be done in this situation is to change out the two blade receptacle to a three blade receptacle. Depending on how old the house wiring is, will depend on whether there is a ground wire in the two wire cable that the house was wired with. It sounds like the old two blade receptacle is worn out and it is the looseness between it and the adapter that is causing the problem. A room heater can be about 1500 watts and that adjusts to 12.5 amps that is heating up and melting your adapter. A new three blade receptacle will be tighter and it will not heat up. If there is a ground wire in the back of the receptacle's junction box attach it to the new receptacle. If there isn't a ground wire in the junction box, replace the receptacle anyhow, it will be much safer that the set up that you have now.
Connect the white wire from the European oven to the white wire in the US receptacle. Connect the black wire from the European oven to the black wire in the US receptacle. Connect the green wire from the European oven to the bare wire in the US receptacle. The green wire serves as the ground wire since you don't have a separate ground wire in the US receptacle.
Look in the back of the range receptacle box that is in the wall. The three wires coming in should have a bare ground wire in the cable set. It wasn't brought to the receptacle because there was no place for it on the three wire receptacle If you find it back there under a screw terminal just add another short piece of wire under the screw and then connect the other end of the short wire to the new ground terminal on the new four position receptacle The wire should be equal in size to the size of the wire that exists around the ground terminal now. If the house is so old that the range cable did not have a ground wire in it the code allows a separate green ground #10 wire to be taken from the breaker panel box to the existing range receptacle This wire is to be bonded on each end. At the panel end to the ground buss and at the receptacle end around the ground screw at the back of the box unbroken and then to the new four position receptacle ground lug.
Black wire is HOT, white wire is NEUTRAL and bare or green wire is GROUND. The black wire goes to brass colored screw, the white wire goes to silver colored screw and the bare wire goes to green screw that is connected to the metal "frame" of the receptacle.
Yes, most definitely. Provisions for the ground wire in the dryer receptacle should be used. The feeder cable's ground wire is first grounded to the receptacle's junction box ground screw and then taken to the receptacle's ground terminal. The dryer plug configuration will match up to the dryers four wire plug in cable. When the plug is connected into the dryer receptacle the ground terminals of both devices will match and the ground wire will be continuous from the voltage source at the distribution panel and complete the circuit at the dryer. This low impedance electrical path will conduct any ground fault that could occur at the dryer and trip the feeder breaker of the dryer circuit, there by removing the fault current from the dryer circuit.
Parallel connect the new receptacle to a receptacle in the existing circuit. Black (hot) existing to black (new), white existing to white (new), ground existing to ground (new). Make the ground wire coming into the new receptacle box longer so that it can be looped around the ground screw located in the receptacle box first and then connect to the receptacle without having a break in the wire.
Run a fused power line from the receptacle to either the battery for constant Hot or to the fuse box for an ignition controlled receptacle and ground the receptacle either by mounting on a metal surface or run a ground wire from the body of the receptacle to a good chasis ground
What should be done in this situation is to change out the two blade receptacle to a three blade receptacle. Depending on how old the house wiring is, will depend on whether there is a ground wire in the two wire cable that the house was wired with. It sounds like the old two blade receptacle is worn out and it is the looseness between it and the adapter that is causing the problem. A room heater can be about 1500 watts and that adjusts to 12.5 amps that is heating up and melting your adapter. A new three blade receptacle will be tighter and it will not heat up. If there is a ground wire in the back of the receptacle's junction box attach it to the new receptacle. If there isn't a ground wire in the junction box, replace the receptacle anyhow, it will be much safer that the set up that you have now.
Connect the white wire from the European oven to the white wire in the US receptacle. Connect the black wire from the European oven to the black wire in the US receptacle. Connect the green wire from the European oven to the bare wire in the US receptacle. The green wire serves as the ground wire since you don't have a separate ground wire in the US receptacle.
Green typically represents a ground so you would connect to the bare wire at receptacle or look for a green headed screw.
Look in the back of the range receptacle box that is in the wall. The three wires coming in should have a bare ground wire in the cable set. It wasn't brought to the receptacle because there was no place for it on the three wire receptacle If you find it back there under a screw terminal just add another short piece of wire under the screw and then connect the other end of the short wire to the new ground terminal on the new four position receptacle The wire should be equal in size to the size of the wire that exists around the ground terminal now. If the house is so old that the range cable did not have a ground wire in it the code allows a separate green ground #10 wire to be taken from the breaker panel box to the existing range receptacle This wire is to be bonded on each end. At the panel end to the ground buss and at the receptacle end around the ground screw at the back of the box unbroken and then to the new four position receptacle ground lug.
Black wire is HOT, white wire is NEUTRAL and bare or green wire is GROUND. The black wire goes to brass colored screw, the white wire goes to silver colored screw and the bare wire goes to green screw that is connected to the metal "frame" of the receptacle.
Yes, most definitely. Provisions for the ground wire in the dryer receptacle should be used. The feeder cable's ground wire is first grounded to the receptacle's junction box ground screw and then taken to the receptacle's ground terminal. The dryer plug configuration will match up to the dryers four wire plug in cable. When the plug is connected into the dryer receptacle the ground terminals of both devices will match and the ground wire will be continuous from the voltage source at the distribution panel and complete the circuit at the dryer. This low impedance electrical path will conduct any ground fault that could occur at the dryer and trip the feeder breaker of the dryer circuit, there by removing the fault current from the dryer circuit.
Using a red wire nut hook the 3 wires (of the same color) together with a short piece of wire of the same color. You now have 4 wires tied together. Now take the other end of the short wire and attach it to the outlet on the correct screw Do the same with the other 2 wires Please keep in mind to make sure the wire nut has securely fastened the wires. Loose connections cause heat which cause fire If you do not completely understand this answer please contact a qualified electrician
To wire receptacles in series, connect the hot wire from the power source to the first receptacle, then connect a jumper wire from the first receptacle to the second receptacle, and so on for each additional receptacle in the series. Finally, connect the neutral wire from the power source to the last receptacle in the series.
The very first thing you do is shut the power off to that circuit if you are going to work on it. A regular duplex receptacle has 5 screws on it. With the receptacle facing you and the U ground pin facing down, the left side (neutral blade, silver screws) connects to the white (neutral) incoming wire. The right side (hot blade, gold screws) connects to the black (hot) incoming wire. The ground wire connects to the green screw on the receptacle Strip and wrap the wires around the appropriate screws. This leaves you two more screws on either side, tighten them snug as no wires go under them. Reinstall the receptacle back into the wall and turn the power back on.
Answer for USA, Canada and countries running a 60 Hz supply service.Range receptacle three to fourFirst thing to do is turn off the breaker to the range. Look in the back of the range receptacle box that is in the wall. The three wires coming in should have a bare ground wire in the cable set. It wasn't brought to the receptacle because there was no place for it on the three wire receptacle. If you find it back there under a screw terminal just add another short piece of wire under the screw and then connect the other end of the short wire to the new ground terminal on the new four position receptacle. The wire should be equal in size to the size of the wire that exists around the ground terminal now. If the house is so old that the range cable did not have a ground wire in it the code allows a separate green ground #10 wire to be taken from the breaker panel box to the existing range receptacle. This wire is to be bonded on each end. At the panel end to the ground buss and at the receptacle end around the ground screw at the back of the box unbroken and then to the new four position receptacle ground lug.Before you do any work yourself,on electrical circuits, equipment or appliancesalways use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.