on smaller stuff its usually 10ma since that is not usually fatal

default for most gfci

on larger stuff if its not connected with RMC even if you pull a ground wire be very careful

pre made cable BX (MC now) comes in large sizes ive used 2/0

the ground is #6 if there isn't a driven ground on the machine the fault could be carried in the little helix of galvanized wrapped around the cable.

now gee ill just put on an ohmmeter and make sure it wont get red hot

remember the word helix. the dc resistance doesnt change no matter what shape the wire is.

so use an LCR bridge not an ohmmeter

a caution sometimes these use 1000hz as a default

sealtite liqitite greenfeild all have this quirk

some have copper with the galvanize steel but the only thing that changes the inductance is the # of turns (well diameter too)

tray cable does not it seems to be always braided but im not positive

some hi voltage cable has the drain wires in a helix and the runs are usually longer .. on the plus side most bigger stuff has any parameter you could name settable in the breaker.

I did once learn the hard way that the suction hose on a 3" water pump is made with the same helix so it wont be pumped flat

takes about 3 amps at 277V

vom says 12 ohms perhaps its stainless wire

pumps merrily away and the hose steams a bit

perhaps the hose is a better ground than the plate at the bottom of the wood pole

plant has 480 277Y pole looked like one leg grounded delta

takes a bit of thought

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Natural Sciences

Why the most earth leakage circuit breakers trip on off condition?

Earth leakage circuit breakers can trip in the off position if there is a fault in the wiring or if the breaker itself is faulty. It could be due to high levels of leakage current or a short circuit. It is a safety feature to prevent electrical hazards and should be investigated by a qualified electrician.


What is the working procedure of EARTH LEAKAGE CIRCUIT BRACKER?

we call them ground fault breakers 10 milliamps thru you instead of the normal current path can kill you if you have a neon test lamp connect it to one of the hot leads and earth the other. if it lights the earth leak detector is faulty. if it opens the breaker its good most here in the usa have a test button


What is mean by 4 pole ELMCB?

A 4 pole ELMCB refers to a 4-pole Earth Leakage Miniature Circuit Breaker. It is a type of circuit breaker that trips when it detects a leakage current to ground, protecting against electric shocks or fire hazards. The 4 poles indicate that the ELMCB provides protection for all phases and the neutral wire in a circuit.


How do you calculate earth leakage current for certain load example 5KW motor 660Vac?

There are many factors that determine what the leakage current will be. You could find out what the insulation winding resistance of the new motor should be and use the 660 volts and Ohm's law to calculate the current. If you measure this using a DC insulation tester however it probably will not yield an exact measurement since the test is not under normal operating conditions, but is a DC voltage test. To get the best measurement you really need to test the motor under operation and use a leakage clamp on the ground connection to see what the current really is since other factors come into play such as the insulation resistance, imbalance and frequency. An example of a tool would be the Fluke 1630 or Fluke 360.


What happen if you connect earth wire in place of neutral wire?

If there's no earth leakage protection unit in your main Distribution Board then the device will operate normally since the neutral and earth conductors are one on the supply side. But if there's Earth Leakage then because of the imbalance in the currents flowing through the Earth Leakage it will trap. What is called 'earth wire' in Europe is called 'ground' in the US and is often bare. Using a bare conductor as a neutral exposes you to potential shock. If the bare wire is properly connected at the panel, all is fine. But if you touch this bare neutral and provide a better grounding connection than the panel provides, you become part of the circuit to whatever device that circuit supplies. What is often missed in this scenario is that with the neutral being after the load, the load limits the current and your shock WILL NOT TRIP THE BREAKER.

Related Questions

What is the difference between Earth Fault Relay and Earth Leakage Relay?

Earth leakage relays are instantaneous tripping relays where as earth fault relays have the option of time and ampere setting i.e. for a setted ampere the circuit breaker will be tripped off after the setted time (in second).


How do you solve earth leakage?

The best way to stop earth leakage is to make sure that the are no active circuits going to ground. This will help keep the circuit running right.


Can loose neutral wire effect the operation of Earth Leakage Circuit Breaker?

Yes, a loose neutral wire can effect the operation of Earth Leakage Circuit Breaker.


What is the function of cable select jumper setting?

The function of cable select jumper setting is to let the cable select which drive takes priority ("master") and which one comes after ("slave").


How does an earth leakage transformer work?

What is the definition of earthing and how it works?


How do you reset the iTunes equalizer?

If you want the iTunes equalizer's controls reset to a central position select Flat from the menu. If you have a favourite setting you wish to reset to select Make Preset from the menu and give your setting a name. You can then select your saved setting from the menu.


How do you select a setting in a dialog box?

click it


What is ELDB in electrical?

ELDB stands for Earth Leakage Detection and Breaker. It is a device used in electrical systems to detect any leakage of current to the earth, which could be potentially dangerous. When a leakage is detected, the ELDB will trip the circuit breaker to cut off the power supply and prevent any electrical accidents. This is especially important in ensuring the safety of individuals and protecting electrical equipment from damage.


What is computer monitor earth leakage?

http://www.irh.com.au/News/news_Wiring.pdf


What is the minimum Earth fault current that an Earth leakage protection unit must be able to sense?

10mA