A #16 copper conductor is not a wiring size that is used in homes. This is because the smallest breaker for residential use is rated for 15 amps. A #16 copper conductor is only rated at 13 amps. For a load of 13 amps over 100 feet a #12 copper would be required.
A 16 gauge wire can typically carry around 10-13 amps at 120V AC over a short distance like 25 feet. It's important to follow standard safety practices and consult with an electrician to ensure that the wire gauge is appropriate for your specific application and local electrical code requirements.
8 gauge wire can typically carry up to 40 amps at 120 volts AC over a distance of 25 feet. However, it is important to consult the specific wire manufacturer's specifications and consider other factors such as temperature, installation conditions, and local electrical codes when determining the ampacity of the wire for a particular application.
The voltage has nothing to do with the capacity of a wire to handle current. A #12 copper wire with an insulation factor of 60, 75 or 90 degrees C is rated at 20 amps.
For a distance of 8 feet and a current of 52 amps, a 6-gauge copper wire would be suitable to safely carry the load while minimizing voltage drop. It's important to adhere to local electrical codes and standards when selecting and installing wiring for any electrical system.
The number of automotive amps a 30-foot strand of copper wire can carry depends on the gauge (thickness) of the wire. For example, a 30-foot strand of 10-gauge copper wire can typically carry up to 40-50 amps for automotive use, while a 30-foot strand of 12-gauge wire might be limited to around 25-30 amps. It's important to consult wire ampacity tables and consider factors like temperature and voltage drop to ensure safe and effective performance.
30 amps is how much a 10-2 wire will carry at 110 feet. 10 gauge wire is only good for thirty amps per the national electrical code. Using 80% of the breakers usage you will actually be getting only 24 amps.
140 AMPS
50 amps.
AWG # 6 copper
Yes, a #10 wire will carry 30 amps for 30 feet. If the load is rated as continuous then the wire will have to be derated to 80% capacity which will leave you with 24 workable amps. If the load demands currents higher that 24 amps then you will have to go to the next wire size up which is a #8 which is rated at 45 amps.
Aluminum 4/0 wire car carry 180 amps at at 75 degrees Fahrenheit or 205 amps at 90 degrees. .
A 16 gauge wire can typically carry around 10-13 amps at 120V AC over a short distance like 25 feet. It's important to follow standard safety practices and consult with an electrician to ensure that the wire gauge is appropriate for your specific application and local electrical code requirements.
If you mean 2/0 copper wire it is rated 175 amps. # 2 wire is 115 amps. If you are referring to 2.0 metric it is rated 15 amps.
8 gauge wire can typically carry up to 40 amps at 120 volts AC over a distance of 25 feet. However, it is important to consult the specific wire manufacturer's specifications and consider other factors such as temperature, installation conditions, and local electrical codes when determining the ampacity of the wire for a particular application.
The distance that a 6 gauge wire can carry 50 amps depends on factors like voltage drop and wire insulation. In general, a 6 gauge wire can carry 50 amps for up to 60-70 feet without significant voltage drop. However, it is recommended to consult with a professional electrician for accurate calculations and safety considerations.
A wire with the stats 14awg and 105 degrees Celsius can carry up to 39 amps.
The voltage has nothing to do with the capacity of a wire to handle current. A #12 copper wire with an insulation factor of 60, 75 or 90 degrees C is rated at 20 amps.