I'm not sure if I understand the question. When using a compound microscope, you always want to start by adjusting the coarse adjustment under low power (like 4x) until you have whatever you are looking at in focus. Then, without moving the adjustment, go to the next power (like 10x or something) and use the coarse adjustment only a little and then use the fine adjustment to get it into focus again. Without touching anything, switch to the next power (say 40x) and DO NOT TOUCH THE COARSE ADJUSTMENT. You will lose your object and have to start all over. Only use the fine adjustment past this point. Again, focus as best as you can. This will depend on the microscope, but some also have a 100x power objective lens. It is best to put a drop of immersion oil onto your sample while you move from 40x to 100x. Then you should only use the fine adjustment a small amount to get your sample into focus. The immersion oil improves the resolution of the image that hits your eye, making it easier to see and not blurry.

User Avatar

Wiki User

16y ago

What else can I help you with?

Continue Learning about Natural Sciences

How should the light intensity control knob be set before turning the microscope on or off?

The light intensity control knob should be set to its lowest setting before turning the microscope off. This prevents the light from suddenly flashing at full intensity when the microscope is turned back on. When turning the microscope on, start with the light intensity set to low and gradually increase it to achieve the desired level for viewing.


What Things to observe after and before returning the microscope?

After returning the microscope, check to ensure that all lens objectives are in the lowest position, the light source is turned off, and the power cord is neatly stowed. Before returning the microscope, clean the lenses with lens paper, ensure the stage is in the lowest position, and cover the microscope to protect it from dust.


What suggestion would you make to manuel to correctly use the microscope to view his cheek cells?

I would suggest Manuel to first ensure the microscope is plugged in and turned on. Then, place a small drop of water containing his cheek cells on a microscope slide. Next, gently place the slide on the stage of the microscope and adjust the focus using the fine focus knob to view the cheek cells clearly.


In what direction should the gas regulator be turned to admit more gas into the barrel?

The gas regulator should be turned clockwise to admit more gas into the barrel.


How is the image changed when looked at under the microscope?

When an image is viewed under a microscope, it is magnified to reveal finer details that are not visible to the naked eye. The microscope allows the viewer to see the intricate structures and textures of the specimen in greater clarity and resolution. This enhanced magnification enables scientists and researchers to study the specimen at a microscopic level, offering insights that would otherwise be impossible to observe.

Related Questions

What part of the microscope should be turned to obtain a clear image under high power?

I believe it's the coarse adjustment.


What part of the microscope doesnt move when the adjustment knob move?

The stage of the microscope, where the specimen is placed, does not move when the adjustment knob is turned. Instead, the focus of the microscope is adjusted by moving the stage up and down by use of the adjustment knob.


What are two procedures should be used to properly handle a light microscope?

Always carry the microscope with two hands, one on the base and one on the arm, to prevent dropping or damage. When focusing, use the coarse adjustment knob first for large adjustments, and then the fine adjustment knob for more precise focusing.


What knob is turned to focus an image under low power on a compound lights microscope?

I'm pretty sure fine adjustment. But coarse adjustment also works. The power doesn't matter, There is ONE difference. Coarse adjustment- A knob that focuses the microscope on the specimen by RAISING and LOWERING the body tube of the scope. Fine adjustment- A knob that adjusts the HEIGHT of the body tube.


Why must the course adjustment knob be turned forward only while watching from the side?

The course adjustment knob must be turned forward only while watching from the side to ensure that the microscope's objective lens moves closer to the specimen. This allows for focusing on the specimen and achieving a clear image. Turning the knob in any other direction may result in moving the objective lens away from the specimen, leading to an out-of-focus image.


What part of the microscope is turned to get a clear image of the specimen?

The focus knob is turned to adjust the focus and get a clear image of the specimen under the microscope. Turning the focus knob moves the lenses up and down to bring the specimen into sharp focus.


How do you adjust the carburetor on your 2003 Shadow Spirit?

The only adjustment you should attempt is the idle adjustment which can be turned clockwise or counter clockwise. You must let the cycle completely warm up before adjusting. All other adjustments should be made by a qualified cycle mechanic. The idle adjuster should be on the left side.


5.7 vortec valve adjustment procedure?

5.7 later valve adjustment procedure begins with the removal of the valve cover. Each valve has an adjustment screw. The screws can be turned to adjust the valves.


Should you Let your boyfried rub your boobs?

Of course! If he wants to do it and you enjoy it.


How should the light intensity control knob be set before turning the microscope on or off?

The light intensity control knob should be set to its lowest setting before turning the microscope off. This prevents the light from suddenly flashing at full intensity when the microscope is turned back on. When turning the microscope on, start with the light intensity set to low and gradually increase it to achieve the desired level for viewing.


How do you change the magnification lens on a microscope?

To change the magnification lens on a microscope, first, ensure that the microscope is turned off. Then, gently unscrew or detach the existing lens from the microscope. Carefully insert the new lens in its place and secure it in position. Finally, test the new lens by turning on the microscope and adjusting the focus as needed.


Why Dash lights will not come on?

There is a adjustment to dim the dash lights the adjustment may be turned dow, some models have a wheel type switch or similar, check owners manual. It is called the rheostat.