No there are no adapters made for these types of installations. The reason there are no adapters is to provide a factor of safety. To plug a 30 amp plug into a 50 amp receptacle could allow 50 amps to be applied to a 30 amp rated cord. The 50 amp receptacle is more than likely being fed by a 40 amp breaker. Just change the plug cord to match the ampacity of the breaker ahead of the 50 amp receptacle. Or change the 50 amp receptacle and 40 amp breaker to a 30 amp breaker and use your existing cord plug.

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Natural Sciences

Is there an adapter for a NEMA 14-30 plug and a NEMA 10-30 receptacle?

A NEMA 14-30 is a 3 pole 4 wire grounding receptacle rated at 30 amps 125/250 volts. A NEMA 10-30 is a 3 pole, 3 wire non grounding receptacle rated at 30 amps 125/250 volt.As the NEMA 10 device has no ground terminal on it, it is not a standard receptacle device so no adapter is made for it.


Is there an adapter for a NEMA 14-30 male plug to a NEMA 10-30 female receptacle?

No there is no adapter. Change your old dryer receptacle NEMA 10-30 to a new NEMA 14-30. This will allow you to plug the new dryer cord into the old wiring.Answer for USA, Canada and countries running a 60 Hz supply service.Range receptacle three to fourLook in the back of the dryer receptacle box that is in the wall. The three wires coming in should have a bare ground wire in the cable set. It wasn't brought to the receptacle because there was no place for it on the three wire receptacle. If you find it back there under a screw terminal just add another short piece of wire under the screw and then connect the other end of the short wire to the new ground terminal (G) on the new four position receptacle. The wire should be equal in size to the size of the wire that exists around the ground terminal now. If the house is so old that the dryer cable did not have a ground wire in it the code allows a separate green ground #10 wire to be taken from the breaker panel box to the existing range receptacle. This wire is to be bonded on each end. At the panel end to the ground buss and at the receptacle end around the ground screw at the back of the box unbroken and then to the new four position receptacle ground lug (G).Before you do any work yourself,on electrical circuits, equipment or appliancesalways use a test meter to ensure the circuit is, in fact, de energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


Where is the neutral wire on a nema 6 20r connector?

The NEMA 6-20R is a 2 pole 3 wire grounding receptacle that is rated for 250 volts. It is not meant to have a neutral wire connected to it. The receptacle is designed to have 240 volts connected to it.


What size receptacle needed for 166 amp 3 phase?

For a 166 amp 3 phase circuit, you would typically need a receptacle that can handle at least 200 amps to provide a safe margin. This would usually correspond to a 208V or 240V 3 phase receptacle with appropriate amperage rating, such as a NEMA L15-30 or L16-30 receptacle. It's critical to consult with a qualified electrician or electrical engineer to ensure the correct receptacle is selected for your specific application and local electrical code requirements.


What is your nema?

Our NEMA (like in NEMA 3R) stands for the National Electric Manufacturers Association.

Related Questions

Is there an adapter for a NEMA 14-30 plug and a NEMA 10-30 receptacle?

A NEMA 14-30 is a 3 pole 4 wire grounding receptacle rated at 30 amps 125/250 volts. A NEMA 10-30 is a 3 pole, 3 wire non grounding receptacle rated at 30 amps 125/250 volt.As the NEMA 10 device has no ground terminal on it, it is not a standard receptacle device so no adapter is made for it.


Is there a converter or adapter for a nema 10-30 plug and nema 6-15 or 6-30 receptacle?

http://www.stayonline.com/detail.aspx?ID=3103 MARINCO 83A Plug Adapter NEMA 5-15 Plug to L5-30 Connector Block Adapter - $45.00 Assure the device does not require more amperage than the receptacle offers.


What are the specifications of the NEMA 15-40 electrical receptacle?

The NEMA 15-40 electrical receptacle is a type of outlet that is designed to handle 250 volts and 40 amps of electricity. It has a specific configuration of prongs and is commonly used for high-powered appliances and equipment.


What are the installation requirements for a NEMA 6-15 receptacle?

The installation requirements for a NEMA 6-15 receptacle include using a dedicated circuit with a 240-volt power supply, ensuring proper grounding, and following the National Electrical Code guidelines for wiring and placement.


Is there an adapter for a NEMA 14-30 male plug to a NEMA 10-30 female receptacle?

No there is no adapter. Change your old dryer receptacle NEMA 10-30 to a new NEMA 14-30. This will allow you to plug the new dryer cord into the old wiring.Answer for USA, Canada and countries running a 60 Hz supply service.Range receptacle three to fourLook in the back of the dryer receptacle box that is in the wall. The three wires coming in should have a bare ground wire in the cable set. It wasn't brought to the receptacle because there was no place for it on the three wire receptacle. If you find it back there under a screw terminal just add another short piece of wire under the screw and then connect the other end of the short wire to the new ground terminal (G) on the new four position receptacle. The wire should be equal in size to the size of the wire that exists around the ground terminal now. If the house is so old that the dryer cable did not have a ground wire in it the code allows a separate green ground #10 wire to be taken from the breaker panel box to the existing range receptacle. This wire is to be bonded on each end. At the panel end to the ground buss and at the receptacle end around the ground screw at the back of the box unbroken and then to the new four position receptacle ground lug (G).Before you do any work yourself,on electrical circuits, equipment or appliancesalways use a test meter to ensure the circuit is, in fact, de energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


What type of electrical outlet is required for a device that needs to be plugged into a 250 volt 20 amp receptacle?

The device requires a 250 volt 20 amp receptacle, which is typically a NEMA 6-20 outlet.


What are the specific requirements for installing a NEMA 6-15 plug in a commercial building?

To install a NEMA 6-15 plug in a commercial building, you will need a dedicated 240-volt circuit with a NEMA 6-15 receptacle, proper wiring, and a licensed electrician to ensure compliance with building codes and safety standards.


Where is the neutral wire on a nema 6 20r connector?

The NEMA 6-20R is a 2 pole 3 wire grounding receptacle that is rated for 250 volts. It is not meant to have a neutral wire connected to it. The receptacle is designed to have 240 volts connected to it.


How do you covert a two prong welder plug to a three prong and ground out let?

Need to know the amperage rating of the plug or the NEMA configuration of the plug and receptacle


What are the necessary requirements for installing a 50 amp welder receptacle in a workshop?

To install a 50 amp welder receptacle in a workshop, you will need a dedicated 50 amp circuit breaker, appropriate gauge wiring (typically 6-gauge for a 50 amp circuit), a NEMA 6-50R receptacle, and proper grounding. It is important to follow local electrical codes and regulations when installing the receptacle to ensure safety and compliance.


What are the specific requirements for installing a NEMA 30 amp plug in a residential setting?

To install a NEMA 30 amp plug in a residential setting, you will need a dedicated circuit with the appropriate wire size (usually 10 AWG), a compatible outlet box, and a NEMA 30 amp receptacle. It is important to follow the National Electrical Code (NEC) guidelines and consult a licensed electrician for proper installation.


Can you make an extension cord that would have a NEMA l5-30p 30a 125v plug on one end and a NEMA l14-30r 30a 125v receptacle on the other end to connect a generator parallel kit to a transfer switch?

Yes. Use 10awg wire, mindfull of length voltage drop.