i have 3 phase coming i have hager 12 way unit to run the sunbed he is ysing one of the phhase to run he shop down ster with is 240 can that be dun

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Natural Sciences

Is transmission voltage a phase to phase voltage or a phase to ground voltage?

Phase to Phase voltageCorrection to the above answer:There is no such thing as a 'phase-to-phase' or 'phase-to-ground' voltage. The correct terms are 'line-to-line' (or 'line voltage') and 'line-to-ground' (or 'phase voltage'). Transmission-line voltages are line-to-line (or 'line') voltages.


What happens to the tetrads in telophase?

During metaphase I of meiosis, tetrads line up along the equator of the cell. They are preparing for separation in the next phase.


What is the Phase to phase voltage of 66KV earthed cable?

Nominal transmission and distribution voltages are line voltages. So '66 kV' is a line-to-line voltage. Note that there is no such thing as a 'phase-to-phase' voltage -the correct term is 'line-to-line'. Using the term, 'phase-to-phase', indicates a lack of understanding of a.c., which is not uncommon! Incidentally, the symbol is 'kV', not 'KV'.


Why is phase voltage not twice line voltage?

Line to line voltage is not the same as line to neutral voltage because line voltages are 120 degrees apart. They are related by: Line to neutral voltage * tan (120 degrees) = Line to neutral voltage * 1.73.Additional CommentFor delta-connected systems, the line voltage is the same as the phase voltage.For wye-connected systems, the line voltage is larger than the phase voltage by a factor of 1.732. The reason for this is as follows:Because any two phase voltages are displaced from each other by 120o, they must be added vectorially, not algebraically, to find the line voltage. As the above answer points out, this means that the relationship between the two is the square-root of 3, or 1.732.


What is phase voltage and line voltage in star connection?

The conductors that connect a three-phase supply to its load are called 'line conductors' or, more simply, 'lines'. The individual generator stator windings, transformer winding, or loads are called 'phases'. Lines and line terminals are identified by colours, letters, numbers, or combinations of letters and numbers. For example, A-B-C. Phases are identified by using the letters assigned to the line terminals between which the phases are connected, e.g A-B, B-C, and C-A. Voltages measured between lines ('line-to-line') are termed 'line voltages', and currents that pass through the lines are called 'line currents'. Voltages measured across a generator's windings, transformer windings, or individual loads, are called 'phase voltages', and the currents that pass through these are called 'phase currents'. For a three-phase, three-wire, system, the phase- and line-voltages are numerically-equal to each other. For a three-phase, four-wire, system, the line voltage is 1.732 times larger than the phase voltage.

Related Questions

What is the line side of the 3 phase transformer?

The primary line side of a 3 phase transformer should be marked H1, H2, H3. The line side is the incoming voltage that you want to step up or step down or isolate.


What is a line to line voltage?

In a 3 phase system, the voltage measured between any two phase is called line to line voltage.And the voltage measured between line to neutral is called phase to neutral (line to neutral) voltage.AnswerThere is no such thing as a 'phase-to-phase' or a 'phase-to-neutral' voltage. The correct terms are 'line-to-line' and 'line-to-neutral'.The voltage between any two line conductors is called a line voltage.In a three-phase, three-wire, system, the line voltage is numerically equal to the phase voltage.In a three-phase, four-wire, system, the voltage between any line conductor and the neutral conductor is called a phase voltage. The line voltage is 1.732 times larger than the phase voltage.


What condition must be met to synchronize an alternator to an existing three-phase power line?

1.The effective voltages of the incoming generator must be exactly equal to that of the others or of the bus bars connecting them.2.The phase rotation or sequence of the running and incoming generators must be same.3. The frequency should be same.


What happens when a conducting rod falls on a three phase line?

shotcircuit and produce spark as huge amount.


What if you have a negative kvar in transmission line what will happens?

the phase angle changes in R Y B lines


Write dowen the relationshipbetween line and phase the 3phase system if voltageline and currentline are line value voltage power and current power are phase value?

A-for star connectionE(line)=1.73E(Phase)I(line)=I(Phase)&B-for delta connectionE(line)=E(Phase)I(line)=1.73I(Phase)


Why do you have voltage to ground but not voltage phase to phase?

There is phase to phase voltage in 3 phase system.AnswerYou don't get voltage 'phase-to-phase'; it's 'line-to-line'!


Is transmission voltage a phase to phase voltage or a phase to ground voltage?

Phase to Phase voltageCorrection to the above answer:There is no such thing as a 'phase-to-phase' or 'phase-to-ground' voltage. The correct terms are 'line-to-line' (or 'line voltage') and 'line-to-ground' (or 'phase voltage'). Transmission-line voltages are line-to-line (or 'line') voltages.


Is 220V line voltage or phase voltage?

Phase, if you are referring to line, as power line from pole.


How can line and staff conflict be reduced?

technicques for reduced line and staff conflict


If in the three phase connection phase to phase voltage is 400v what will be the phase neutral voltage?

The formula to use is, phase voltage /1.73 = phase to neutral (ground) voltage.CommentThere is no such thing as a 'phase to phase', or 'phase to neutral' voltage. The correct terms are 'line to line' and 'line to neutral'. So the above answer should read: line voltage/1.73= line to neutral voltage = phase voltage.


In three phase current the phase to phase is connected what will happen?

This is called a "line-to-line" short and it will trip either the main circuit breaker in the panel, or the fuse protecting the panel. It might also result in personal injury if someone is in contact with the equipment when the short happens. Equipment or damage is also possible.