answersLogoWhite

0

A high-impedance voltmeter is most appropriate.

User Avatar

Wiki User

12y ago

What else can I help you with?

Continue Learning about Natural Sciences

What is the maximum volt-ampere loading permitted on a 20-ampere branch circuit with a continuos load is?

The wattage of the circuit presuming that the circuit voltage is 120 volts. 20 x 120 = 2400 watts. Circuit loading on a continuous load is 80% so 2400 watts x .8 = 1920 watts


How does the loading effect of an ammeter in a low resistance circuit compare to the loading effect in a high resistance circuit?

The voltmeter has an internal resistance, which should be as high as possible. As this resistance draws current from the circuit under test, it will affect circuit operation. This is more pronounced in a high impedance circuit because the current drawn flows through higher resistances.


How many 8 milliamp lamps can you put on a 20 Amp circuit?

There are 1,000 miliamps in 1 amp. As the NEC limits you to loading a lighting circuit to no more than 80% you can have 16 amps or 16,000 miliamps on that circuit. That would mean you can have 2,000 lamps of 8 miliamps each.


How many 15 amps sockets can i connect in a single circuit?

Circuit loading In Canada the code rule is, there shall be not more that 12 outlets on any 2 wire branch circuit. Such outlets shall be considered to be rated at not more that 1 amp per outlet. Where the connected load is known, the number of outlets may exceed 12 providing the load current does not exceed 80 % of the rating of the over current device protecting the circuit.


Why does plugging too many appilances into the same circuit cause too much current to flow through the circuit what will happen as a result?

Each appliance has its own amperage. This can be shown by looking at the label of each appliance. A circuit is protected by a breaker which has a trip limit. By continually adding more amperage from different appliances, the circuit becomes overloaded. When the circuits limit is reached because of the additive effect of more appliances to the circuit the breaker will trip. This disconnects the appliance loads from the distribution panel supply and prevents over loading of the conductors of that circuit. Without removing some of the load amperage, the breaker will keep tripping when reset.

Related Questions

What is loading effect?

An instrument to be able to really tell the value is mandatory that the instrument does not load the circuit making it a false reading or inaccurate loading effect which means when we give high load that may be cause to some fake or inaccurate of output, this may be known as loading effect....


What is a top load?

A top loading balance is a digital instrument that is used to measure the mass of an object. It consists of a metal plate to place the object and a digital read out the measures in the S.I. unit gram.


Which ammeter DMM or VOM has the higher loading effect Why?

A digital multimeter (DMM) typically has a lower loading effect compared to a volt-ohm meter (VOM), particularly older analog models. The loading effect refers to the impact a measuring device has on the circuit being measured; a higher loading effect can alter the circuit's behavior. DMMs generally have higher input impedance, which minimizes the current drawn from the circuit, resulting in less loading. In contrast, VOMs, especially those with lower impedance, can significantly affect circuit performance when measuring current.


What is loading effect in measurement?

The loading effect in measurement refers to the alteration of the quantity being measured due to the act of measuring it. This effect occurs when the instrument used to measure the quantity draws current or energy from the circuit under test, thereby affecting the circuit's performance. It can lead to inaccuracies in measurements, especially in circuits with high impedance. To minimize the loading effect, it is important to use measurement instruments with high input impedance.


What is the maximum volt-ampere loading permitted on a 20-ampere branch circuit with a continuos load is?

The wattage of the circuit presuming that the circuit voltage is 120 volts. 20 x 120 = 2400 watts. Circuit loading on a continuous load is 80% so 2400 watts x .8 = 1920 watts


How does the loading effect of an ammeter in a low resistance circuit compare to the loading effect in a high resistance circuit?

The voltmeter has an internal resistance, which should be as high as possible. As this resistance draws current from the circuit under test, it will affect circuit operation. This is more pronounced in a high impedance circuit because the current drawn flows through higher resistances.


What is a description of the loading effect of an ammeter?

loading of an ammeter in a circuit decreases the flow of current,so it has to be calculated to reduce expected errors in the operations


How you can eliminate loading effect in amplifiers?

By increasing the input impedance of amplifier.


How you can minimize the loading effect on voltmeter?

To minimize the loading effect on a voltmeter, use a voltmeter with a high input impedance. This will ensure that the voltmeter draws as little current as possible from the circuit being measured, reducing the impact on the voltage being measured. Additionally, connecting the voltmeter in parallel with the circuit, rather than in series, can also help minimize the loading effect.


What is specific electric loading?

Specific electrical loading is the insertion of impedance into a circuit to change the characteristics of the circuit. In contrast, specific magnetic loading is the ratio between the average flux air gap to the flux path of the air gap. These two terms have nothing to do with each other and are therefore independent of each other.


What is a top loading balance?

A top loading balance is a digital instrument that is used to measure the mass of an object. It consists of a metal plate to place the object and a digital read out the measures in the S.I. unit gram.


What is the difference between direct loading and phantom loading?

Phantom loading consits of supplying the pressure circuit from a seperate low voltage supply. It s possible to circulate rated current through the curent circuit with a low voltage supply as the impedance of this is very low. therfore the total power required for testing the meter is compartively smal with phantom loading.