NMD wire is a type of electrical wire commonly used in residential construction in Canada. It consists of two or three insulated copper conductors, with a PVC sheath for protection. NMD stands for Non-Metallic Sheathed Cable.

User Avatar

AnswerBot

1y ago

What else can I help you with?

Continue Learning about Natural Sciences

You want to wire up a receptacle to run a 2 hp 230 volt dust collector you have some NMD 90 14-2 available The run is about 50 feet from the panel Is this wire suitable and adequate?

No, NMD 90 14-2 wire is not suitable for a 2 hp 230 volt dust collector. You would need to use a wire with a higher ampacity such as NMD 90 10-3 wire to handle the current required for a 2 hp motor. Ensure to consult with a qualified electrician for proper wire sizing and installation.


Can the neutral wire beused to make a 2 wire system into a three wire outlet?

No, never use the neutral conductor for anything but a neutral. If the house has no grounding system then there is no need to connect the fan ground wire to anything. Just keep in mind that the wiring in the house could be 70 plus years old and the insulation on this wire will be starting to break down if handled too much. Just cap the wire off and install the fan. Old two wire knob and tube systems were used in the 20's and they never used a ground with them. In the 40's NMD cable was used but it also never had a ground wire. It was in the early 60's that the third wire was added to NMD cable, it was a bare copper wire that was used for grounding equipment. Now the new wiring code states that there must be a grounding system in place for new installations.


What is yellow romex wire used for?

Romex is a manufactures name for NMD 7 and 90. Another manufacturer's named their product Loomex. On NMD 7 the insulation factor was 75 degrees C, later the manufactures came out with NMD 90 which has an insulation factor of 90 degrees C. NMD stands for Non Metallic for Dry locations. Colour coding started a few years ago. It helps the electrical inspector to make sure the correct circuits are going to the correct places. White PVC jacket is for 2 & 3C #14 for General Application Blue PVC jacket is for 2C#14 for Bedroom Outlets terminating at Arc Fault Circuit Interrupters (AFCI) Yellow PVC jacket is for #12 AWG Orange PVC jacket is for #10 AWG White PVC jacket is for #8 AWG and larger size wires Red PVC jacket is designed for use on 240-volt systems where there is no neutral


White wire a black wire a red wire and a bare wire?

The white wire is typically neutral, the black wire is usually hot or live, the red wire may be a secondary live wire or used for a separate function, and the bare wire is typically the ground wire for safety purposes in an electrical circuit.


What colour wire goes to the breaker using 12-2 wire?

For a typical 12-2 wire, the black wire is the "hot" wire that connects to the breaker, the white wire is the neutral wire that connects to the neutral bus bar, and the bare copper wire is the ground wire that connects to the ground bus bar in the circuit panel.

Related Questions

You want to wire up a receptacle to run a 2 hp 230 volt dust collector you have some NMD 90 14-2 available The run is about 50 feet from the panel Is this wire suitable and adequate?

No, NMD 90 14-2 wire is not suitable for a 2 hp 230 volt dust collector. You would need to use a wire with a higher ampacity such as NMD 90 10-3 wire to handle the current required for a 2 hp motor. Ensure to consult with a qualified electrician for proper wire sizing and installation.


What does nmd mean after a dr's name?

“Doctor of Naturopathic Medicine”


What does NMD mean after a doctors name?

Naturopathic Medical Doctor


What do the initials NMD stand for after a doctors name?

Naturopathic Medical Doctor


How old is Alissa-Mae From NMD?

She just turned 14 in March.


What is the difference between a DO and an NMD?

what is the difference between a Doctor of Osteopathy and a Naturopathic Doctor


Can the neutral wire beused to make a 2 wire system into a three wire outlet?

No, never use the neutral conductor for anything but a neutral. If the house has no grounding system then there is no need to connect the fan ground wire to anything. Just keep in mind that the wiring in the house could be 70 plus years old and the insulation on this wire will be starting to break down if handled too much. Just cap the wire off and install the fan. Old two wire knob and tube systems were used in the 20's and they never used a ground with them. In the 40's NMD cable was used but it also never had a ground wire. It was in the early 60's that the third wire was added to NMD cable, it was a bare copper wire that was used for grounding equipment. Now the new wiring code states that there must be a grounding system in place for new installations.


What is yellow romex wire used for?

Romex is a manufactures name for NMD 7 and 90. Another manufacturer's named their product Loomex. On NMD 7 the insulation factor was 75 degrees C, later the manufactures came out with NMD 90 which has an insulation factor of 90 degrees C. NMD stands for Non Metallic for Dry locations. Colour coding started a few years ago. It helps the electrical inspector to make sure the correct circuits are going to the correct places. White PVC jacket is for 2 & 3C #14 for General Application Blue PVC jacket is for 2C#14 for Bedroom Outlets terminating at Arc Fault Circuit Interrupters (AFCI) Yellow PVC jacket is for #12 AWG Orange PVC jacket is for #10 AWG White PVC jacket is for #8 AWG and larger size wires Red PVC jacket is designed for use on 240-volt systems where there is no neutral


How do you wire up a extractor fan for a bathroom so it can be turned on and off via light switch and the fan has no timer?

Answer for USA, Canada and countries running a 60 Hertz supply service.First thing to do is turn off the breaker to that circuit. The fan has to be wired in parallel with the bathroom light. If you can access the light junction box from the back side (eg. in an attic space) install a two wire NMD #14 cable to the position of the new fan. Disconnect the bathroom fixture's black and white wires from the bathroom light. Connect the new NMD #14 wire to the wires you just removed the fixture from. Make a pigtail of 6 inches long from a piece of the black and white # 14 wire. Connect the white pigtail into the two white wires by twisting all three together and installing the proper size wire nut. Do the same with the black wires. Reconnect the bathroom fixture to the pigtail wires and reinstall the fixture to the junction box. Connect the new extractor fan to the free end of the NMD #14. Now when you turn on the light the new fan will also come on. Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energizedIF YOU ARE NOT REALLY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


What are the top 6 popular bodyboards?

1) NMD 2) manta 3)lmnop 4) Bz 5)4play 6) Turbo = most popular - doesnt mean best quality 1) Versus (VS) 2)NMD 3)Turbo 4)Science 5)Pride 6)Found 7)Morey


What is the unit of precipitation?

A unit of precipitation is usually an inch. Both snow and rain are measured in inches. Rain is also measured in fractions of inches.


Where did the dragonuv come from?

The Dragunov SVD came from the Soviet Union. It was manufactured in several Soviet republics, the Peoples' Republic of China (as the NMD-86), and in Serbia (formerly one of the republics of Yugoslavia).