answersLogoWhite

0

Answer for USA, Canada and countries running a 60 Hz supply serviceCommon 120 volt residential outlets have a wire size of 14 or 12 gage. In general an outlet is made for a wide range of wire sizes. Each of the outlets has a different arrangement of pin slots so that only the correct plug can fit into the matching outlet. The outlets are given names by National Electrical Manufacturers Association (NEMA).

<><><>

NEC or NFPA 70

residential

duplex receptacle circuits SHALL be 20A ( #12)

kitchens SHALL have a minimum of 2 20A circuits

each receptacle SHALL be considered a 350VA load for load calculations

(more than 6 receptacles on one circuit and you better add another circuit)

fixed appliances Shall have their own circuit

Stove, oven, range, garbage disposal, refrigerator,freezer

are sometimes built in and sometimes have a plug and cord if built in

its not good karma to put a toaster on top of the refrigerator and plug it in the same socket.

laundry appliances ( Washer dryer ) have their own circuits

(always considered fixed appliances)

lighting circuits may be 15a depending on lighting load

--------------<><>---------------

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.

If you do this work yourself, always turn off the power

at the breaker box/fuse panel

BEFORE you attempt to do any work

AND

always use a meter or voltage indicator

to insure the circuit is, in fact, de-energized.

IF YOU NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Wiki User

14y ago

What else can I help you with?

Continue Learning about Natural Sciences

Can you use 10 ga wire on a 15 amp receptacle?

No, it is not recommended to use 10 gauge wire with a 15 amp receptacle. The wire gauge should match the amperage rating of the receptacle to ensure safe and proper functioning of the electrical system. In this case, a 15 amp receptacle should be used with 14 gauge wire.


What is the smallest size wire that can be installed in a parallel permitted by the nec?

The National Electrical Code (NEC) permits a minimum wire size of 14 AWG for general lighting and receptacle circuits in parallel installations.


What are the common wiring in a receptacle?

Black wire is HOT, white wire is NEUTRAL and bare or green wire is GROUND. The black wire goes to brass colored screw, the white wire goes to silver colored screw and the bare wire goes to green screw that is connected to the metal "frame" of the receptacle.


How do you wire a 3 wire European oven white black green to a US receptacle with 4 wires white black red and bare?

Connect the white wire from the European oven to the white wire in the US receptacle. Connect the black wire from the European oven to the black wire in the US receptacle. Connect the green wire from the European oven to the bare wire in the US receptacle. The green wire serves as the ground wire since you don't have a separate ground wire in the US receptacle.


Your electric stove has a 3 prong plug your new stove has a 4 prong stove you bought a new 4 prong outlet but on your old outlet it oly has 3 wires no ground wire how do you ground it?

Look in the back of the range receptacle box that is in the wall. The three wires coming in should have a bare ground wire in the cable set. It wasn't brought to the receptacle because there was no place for it on the three wire receptacle If you find it back there under a screw terminal just add another short piece of wire under the screw and then connect the other end of the short wire to the new ground terminal on the new four position receptacle The wire should be equal in size to the size of the wire that exists around the ground terminal now. If the house is so old that the range cable did not have a ground wire in it the code allows a separate green ground #10 wire to be taken from the breaker panel box to the existing range receptacle This wire is to be bonded on each end. At the panel end to the ground buss and at the receptacle end around the ground screw at the back of the box unbroken and then to the new four position receptacle ground lug.

Related Questions

What is the recommended ground rod wire size for ensuring proper electrical grounding in a residential building?

The recommended ground rod wire size for ensuring proper electrical grounding in a residential building is typically 6 AWG copper wire.


What is the recommended wiring configuration for installing a 20 amp 220 volt receptacle in a residential setting?

The recommended wiring configuration for installing a 20 amp 220 volt receptacle in a residential setting is to use a 12-gauge wire with a dedicated circuit breaker. The receptacle should have two hot wires (black and red), a neutral wire (white), and a ground wire (green or bare copper). It is important to follow local electrical codes and consult a licensed electrician for proper installation.


How do you wire a receptacle to a switch?

To wire a receptacle to a switch, you need to connect the hot wire from the power source to the switch, then connect another wire from the switch to the receptacle. Make sure to turn off the power before starting and follow proper wiring diagrams to ensure safety and functionality.


What is the recommended AC wire size for a residential air conditioning unit?

The recommended wire size for a residential air conditioning unit is typically 10 or 12 gauge wire.


Can you use 10 ga wire on a 15 amp receptacle?

No, it is not recommended to use 10 gauge wire with a 15 amp receptacle. The wire gauge should match the amperage rating of the receptacle to ensure safe and proper functioning of the electrical system. In this case, a 15 amp receptacle should be used with 14 gauge wire.


What is the recommended gauge size for a 20amp wire in a residential electrical circuit?

The recommended gauge size for a 20 amp wire in a residential electrical circuit is typically 12 AWG (American Wire Gauge).


What are the specific requirements for installing a NEMA 30 amp plug in a residential setting?

To install a NEMA 30 amp plug in a residential setting, you will need a dedicated circuit with the appropriate wire size (usually 10 AWG), a compatible outlet box, and a NEMA 30 amp receptacle. It is important to follow the National Electrical Code (NEC) guidelines and consult a licensed electrician for proper installation.


How do you wire receptacles in series?

To wire receptacles in series, connect the hot wire from the power source to the first receptacle, then connect a jumper wire from the first receptacle to the second receptacle, and so on for each additional receptacle in the series. Finally, connect the neutral wire from the power source to the last receptacle in the series.


What is the appropriate gauge size for a 10 amp wire in a residential electrical circuit?

The appropriate gauge size for a 10 amp wire in a residential electrical circuit is typically 14 AWG (American Wire Gauge).


What is the proper wiring configuration for a 4 wire 50 amp receptacle?

The proper wiring configuration for a 4 wire 50 amp receptacle includes connecting the black and red wires to the hot terminals, the white wire to the neutral terminal, and the green or bare wire to the ground terminal. It is important to follow the manufacturer's instructions and consult a professional electrician if needed.


What is the proper installation procedure for a 50 amp 4 wire receptacle?

To properly install a 50 amp 4 wire receptacle, first turn off the power to the circuit. Connect the black and red wires to the brass terminals, the white wire to the silver terminal, and the green or bare wire to the green terminal. Secure the wires with the appropriate screws and cover the receptacle with a faceplate. Test the receptacle to ensure it is working correctly before use.


What are the best practices for installing HVAC wire in a residential setting?

The best practices for installing HVAC wire in a residential setting include following local building codes, using the correct wire size and type for the system, securing the wire properly to prevent damage, and ensuring proper insulation and protection from moisture. It is also important to label wires for easy identification and to test the system after installation to ensure proper functioning.