For two 4500W heating elements, you would typically require a double pole 20 amp breaker for each element. This would provide adequate protection for the heating elements and ensure proper functioning of the circuit.
When installing a circuit breaker, you size the breaker based on the wire size. The breaker should be matched to the ampacity of the wire to ensure proper protection against overloads and short circuits. The device being controlled by the breaker is not a determining factor in sizing the breaker.
The size of the breaker for a furnace will depend on the specific requirements of the furnace unit. It is recommended to check the furnace's user manual or consult with a qualified electrician to determine the correct breaker size for your particular furnace model. Using the wrong size breaker can be a safety hazard.
The biggest circuit breaker in any home is the main breaker located in your main breaker panel that is installed where your electrical service cable comes into your home.
The breaker size for a Goulds Century pump 1081 would depend on the specific model and voltage requirements. Refer to the owner's manual or the nameplate on the pump motor for the correct breaker size recommended by the manufacturer. It is important to match the breaker size with the electrical requirements to ensure safe operation.
The formula you are looking for is I = W/E.
It depends on the rating of the furnace. There should be a plate or sticker somewhere on the furnace that shows the rating. If you are just powering a blower motor the rating will be lower than if you have an electric heating element.
In North America the standard sizes for breakers are 15, 20, 30, and 40 amps. The 15 amp size breaker is used in general circuit wiring. The 20 amp size breaker is used for dedicated appliance receptacles, hot water tank and baseboard heating. The 30 amp size breaker is used for a clothes dryer. The 40 amp size breaker is used for the electric range.
The kilowatts will very depending on the size of the heating element(s) and the size of the pump(s).
When installing a circuit breaker, you size the breaker based on the wire size. The breaker should be matched to the ampacity of the wire to ensure proper protection against overloads and short circuits. The device being controlled by the breaker is not a determining factor in sizing the breaker.
The appropriate water heater breaker size is determined by the water heater's wattage and voltage, as indicated in the water heater breaker size chart. It is important to match the breaker size to the specifications of the water heater to ensure safe and efficient operation.
Add up your amps to calculate your breaker size. Add up your loads (amps), divide by 0.8, and choose that size breaker. If that number does not correspond to a standard size breaker you go to the next higher standard size breaker.
Depends on the wire size you are using. If the generator breaker is a 30 amp then install a 30 amp breaker.
The appropriate breaker size for a washer is typically 15-20 amps.
The size of the heating element in the bird bath will determine the temperature. This in a colder climate will want to use a larger heating element. Most areas should keep the water between 40 and 50 degrees.
Normally AWG #10 wire on a 30 amp breaker but it really depends on the size of the pump. The pump manufacture will specify the size wire and size breaker needed.
The size of the breaker for a furnace will depend on the specific requirements of the furnace unit. It is recommended to check the furnace's user manual or consult with a qualified electrician to determine the correct breaker size for your particular furnace model. Using the wrong size breaker can be a safety hazard.
The recommended breaker size for a hot tub is typically 50 amps.