For a 75-foot run on a 15 amp circuit, you would typically use 14-gauge copper wire for general household applications. This wire size is rated to safely carry the maximum current of a 15 amp circuit. Be sure to consult local electrical codes and regulations for specific requirements.

User Avatar

AnswerBot

1y ago

What else can I help you with?

Continue Learning about Natural Sciences

How expensive is correcting 20 amp breakers with 14 gauge wire?

If you plan to do it yourself fairly inexpensive.Depending on the type of panel you have breakers start as low as $3.00 for a 15amp breaker. If you are looking to have a professional do it you will probably pay at least $5.00 per breaker plus whatever the going rate for labor in your area is.


How do you add more breakers to a main supply panel?

New breakers can be purchased separately, and simply snapped into place in the modern breaker panels. Turn power off to panel before removing breaker panel plate. If you do not know what you're doing, save your life and hire an electrician to do it.


Can a 100 amp main have 2 50 amp breakers?

Yes.Additional InformationBreakers and fuses protect the wires to prevent fire. The 100 Amp breaker in the meter base (main) protects the wire from the meter base to the breaker panel. The 50 Amp breaker in the breaker panel protects the wire from the breaker panel to the outlet. Sometimes the 100 amp main breaker is located in the panel.If you are asking "Can you use two 50 amp breakers for the main breakers with a 100 amp service, then yes you can. The National Electrical Code allows you to use up to 6 breakers as the main overcurrent protection.


What is an electric shared neutral?

An electric shared neutral is the white or negative wire that is shared between two electrical circuits on a basic single phase system. Most electrical devices use 120 volts and require a "hot" wire and a neutral wire to operate. Some larger devices use 240 volts and require two "hot" wires to operate. Two circuit breakers in an electrical panel can share one neutral wire as long as the breakers are not on the same "leg" of power. When looking at an electrical panel there are usually two "legs" of power feeding all the breakers, each leg has 120 Volts to ground, if the "legs" are combined you will have 240 Volts. A neutral wire can be shared by two circuits as long as the breakers are on separate "legs". If someone needed to add two circuits in their home, the could run what is called a 3-wire romex, It has a black wire, a red wire, a white wire and a ground wire. The white wire is the neutral for both the black and red 120 volt circuits, and the breakers for the new circuits would need to be on separate "legs" in the panel.


What size wire is needed to feed a 125 amp sub panel from a 200 amp panel less than 200 wire feet away?

For a 125 amp sub panel located less than 200 feet away from a 200 amp panel, you would typically use a 2 AWG copper wire or 1/0 AWG aluminum wire to safely carry the current load. It's important to follow local electrical codes and regulations when selecting the wire size.

Related Questions

What type of wire do you need to run a 60 amp sub panel with 3 20 amp single breakers in the panel?

I would use 4 AWG copper to be safe.


How expensive is correcting 20 amp breakers with 14 gauge wire?

If you plan to do it yourself fairly inexpensive.Depending on the type of panel you have breakers start as low as $3.00 for a 15amp breaker. If you are looking to have a professional do it you will probably pay at least $5.00 per breaker plus whatever the going rate for labor in your area is.


How do you add more breakers to a main supply panel?

New breakers can be purchased separately, and simply snapped into place in the modern breaker panels. Turn power off to panel before removing breaker panel plate. If you do not know what you're doing, save your life and hire an electrician to do it.


What information does the sub panel wire size chart provide for determining the appropriate wire size for a sub panel installation?

The sub panel wire size chart provides information on the recommended wire size based on the amperage of the sub panel, the distance the wire needs to run, and the type of wire insulation. This helps determine the appropriate wire size for a sub panel installation to ensure safety and efficiency.


Can a 100 amp main have 2 50 amp breakers?

Yes.Additional InformationBreakers and fuses protect the wires to prevent fire. The 100 Amp breaker in the meter base (main) protects the wire from the meter base to the breaker panel. The 50 Amp breaker in the breaker panel protects the wire from the breaker panel to the outlet. Sometimes the 100 amp main breaker is located in the panel.If you are asking "Can you use two 50 amp breakers for the main breakers with a 100 amp service, then yes you can. The National Electrical Code allows you to use up to 6 breakers as the main overcurrent protection.


How to wire a sub panel for electrical distribution in a residential setting?

To wire a sub panel for electrical distribution in a residential setting, you will need to connect the sub panel to the main panel using appropriate gauge wires, install a grounding rod, and properly size the breakers for the circuits. It is important to follow local electrical codes and regulations to ensure safety and compliance.


What is a branching circuit?

Each of the circuit breakers in the service panel controls electricity on a branch circuit. A branch circuit is typically a loop of wire that runs from the service panel, out to receptacles, light fixtures, appliances, etc. and back again.


What is an electric shared neutral?

An electric shared neutral is the white or negative wire that is shared between two electrical circuits on a basic single phase system. Most electrical devices use 120 volts and require a "hot" wire and a neutral wire to operate. Some larger devices use 240 volts and require two "hot" wires to operate. Two circuit breakers in an electrical panel can share one neutral wire as long as the breakers are not on the same "leg" of power. When looking at an electrical panel there are usually two "legs" of power feeding all the breakers, each leg has 120 Volts to ground, if the "legs" are combined you will have 240 Volts. A neutral wire can be shared by two circuits as long as the breakers are on separate "legs". If someone needed to add two circuits in their home, the could run what is called a 3-wire romex, It has a black wire, a red wire, a white wire and a ground wire. The white wire is the neutral for both the black and red 120 volt circuits, and the breakers for the new circuits would need to be on separate "legs" in the panel.


How to wire a breaker panel correctly?

To wire a breaker panel correctly, follow these steps: Turn off the main power supply to the panel. Connect the hot wires to the breaker terminals. Connect the neutral wire to the neutral bus bar. Connect the ground wire to the ground bus bar. Install the breakers in the panel and secure them in place. Turn on the main power supply and test the panel to ensure it is working properly. It is important to follow all safety precautions and local electrical codes when wiring a breaker panel. If you are unsure or uncomfortable with the process, it is recommended to hire a licensed electrician.


What is the recommended wire size for a 60 amp sub panel located 100 feet away?

For a 60 amp sub panel located 100 feet away, it is recommended to use a 6-gauge wire size to ensure proper electrical conductivity and safety.


What gauge wire to use for direct burial for a garage that is 400 feet from your house?

Depends on the size of the sub-panel in that garage. If you are installing a 60 amp sub-panel 400 feet away from the main service panel then use AWG # 4.


What size wire is needed to feed a 125 amp sub panel from a 200 amp panel less than 200 wire feet away?

For a 125 amp sub panel located less than 200 feet away from a 200 amp panel, you would typically use a 2 AWG copper wire or 1/0 AWG aluminum wire to safely carry the current load. It's important to follow local electrical codes and regulations when selecting the wire size.