A motor control center (MCC) needs a main breaker when it serves multiple motor circuits and requires overcurrent protection for the entire assembly. This ensures that in the event of an overload or fault, the main breaker can isolate the MCC from the power supply, protecting both the equipment and personnel. Additionally, a main breaker may be required by local electrical codes or standards to enhance safety and compliance in industrial or commercial settings.

User Avatar

AnswerBot

1mo ago

What else can I help you with?

Related Questions

What is different between feeder breaker and motor breaker?

You have to be careful with terms in the electrical field, Example: Main Feeder Circuits will feed a Transformer for distribution and each of those main circuits might feed numbeous Motor control centers. However each of those circuits could be called a main feeder for the motor control center. Confusing. We have High Voltage Transmittion tansformered down for Distribution. So normally a Feeder Breaker will feed Main circuits that will be used for distribution. Example Your home panel will have a main feeder circuit to the whole panel and distribution breakers to you home.


What is the main source voltage on a motor control center?

120


What cause the Main Breaker trips when I start a 30KW 3-phase Motor(Star Delt Starter)?

The wiring is like this:[[30KW Motor ---- Star Delt Starter(100A Breaker inside) ----- 200A Breaker------50A Breaker(Inside the breaker box which located inside the factory) -----100A Main Breaker]]Once I try to start the Motor, the Main Breaker trips immediately.


Looking for a basic standard type answer to how many circuit breaker amps are needed per motor horsepower on 3 phase?

The main breaker is not based on the HP of the motor it is based on the FLA of the motor. Many different motors have different characteristics and all of the different motors have different amperages Once you have the amperage of the motor the breaker is 250% times the FLA of the motor.


What prevents the main circuit breaker and the mission essential circuit breaker of the secondary distribution center from being energized simultaneously?

an interlocking device


Main visceral control center of the body?

hypothalamus


What part of the nervous system is considered to be the main center of control or our swithiching center?

the brain


What is the maximum amperage capacity of the main breaker in a 100 amp sub panel with main breaker?

The maximum amperage capacity of the main breaker in a 100 amp sub panel with a main breaker is 100 amps.


What is the recommended size for the main breaker in a residential electrical panel, specifically for a 125 amp main breaker?

The recommended size for a main breaker in a residential electrical panel with a 125 amp main breaker is typically 150 amps.


What is the purpose of a sub panel with a main breaker in an electrical system?

The purpose of a sub panel with a main breaker in an electrical system is to provide a secondary distribution point for electricity in a building, allowing for additional circuits to be added without overloading the main panel. The main breaker in the sub panel serves as a disconnect switch for the circuits connected to it, providing safety and control over the flow of electricity.


Can an older pool pump draw more amps to trip main breaker?

Yes, an older pump/motor can draw more amps. This usually happens when the motors windings are going bad or the bearings are going out. This causes the motor to have to work harder to rotate. It should have its own breaker. If its blowing your main, The motors windings are probably bad and the motor should be replaced.