A four blade dryer plug cord should have a red, black, white, and green wire in the cord set. The red and black wires are the ones that deliver the 240 volts to the dryer. Black and white deliver control 120 volts to the dryer and also drive the motor to turn the dryer drum. On some dryers they use the red and white for the motor and black and white for the control. As for the green it is always the ground wire.

User Avatar

Wiki User

15y ago

What else can I help you with?

Continue Learning about Natural Sciences

What is the extension cord with 3 prong could be used for?

Depends on the size of the wire in the extension cord. The 3 prong is just the hot, neutral, and ground.


What is wrong if you changed a four prong to a three prong and the dryer is not heating?

My question is WHY did you replace a four prong dryer plug with a three prong! 220 volt Electric dryers require two hot legs, a neutral and a system ground wire. Sounds as though you shunted one of the hots or the neutral. You need to install a four prong plug of the same configuration and wire it exactly as the original.


How do you change a 4 prong cord to a 3 prong cord on dryer?

I needed that answer years ago and was told that the two outer wires are the hot leads and can be interchanged on the two outer lugs on the machine, the center wire is your neutral and needs to be attached to the center lug( the neutral lug on the machine is almost always silver, the hots are brass color) it's really simple once you know,outer to outer, center wire to center lug.


Is it possible to put a 4-prong plug on a dryer that uses a 3-prong plug and how would you do this?

If you are viweing this because you want to change the newer 4-prong plug/outlet to fit an older 3 prong outlet/plug don't do it! The newer plug is safer and the 3 prong plug no longer meets code. See the discussions in other threads. all you need to do is hook the two hot leads on the outer terminals, then the nueatral, white wire on the center terminal and the green ground wire to the ground screw. Be sure to remove the bonding jumper that ties the neutral to the chassis. This is no longer needed as now you have a ground line from the outlet. There should be 3 insulated lugs in the dryer, two hots and a neutral. Connect the red and black wires in your new cord to the hot lugs (red & black are interchangeable), and the white neutral to the neutral lug. Neutral is the center wire on your older 3-wire cord, for reference. Connect the green ground wire directly to the chassis of the sryer using a convienent screw. Use the four prong cord if you can. It is safer because it has the extra ground wire which older cords did not.


Is the wide side of a 2 prong cord hot or ground?

The wider prong of a 2 prong cord is typically the "hot" wire, meaning it carries the current to power a device. The narrower prong is the ground wire, which provides a pathway for current to safely flow in the event of a fault. It is important to always check the manufacturer's instructions or consult a professional electrician for proper identification and use of electrical cords.

Related Questions

What is the wiring diagram for a 4 prong dryer cord?

A 4 prong dryer cord wiring diagram typically includes four wires: a black wire for hot, a red wire for hot, a white wire for neutral, and a green wire for ground. Each wire connects to a specific terminal on the dryer. It's important to follow the manufacturer's instructions and ensure the cord is installed correctly for safety.


How to hook up a 3 prong dryer cord correctly?

To hook up a 3 prong dryer cord correctly, first make sure the dryer is unplugged. Then, connect the neutral wire to the center terminal, the hot wire to the left terminal, and the ground wire to the right terminal. Tighten the screws securely and plug in the dryer to test it.


What is the correct wiring diagram for a 3 prong dryer cord?

The correct wiring diagram for a 3 prong dryer cord is to connect the neutral wire to the center terminal, the hot wire to the left terminal, and the ground wire to the right terminal. Make sure to follow the manufacturer's instructions for your specific dryer model.


What is the proper way to install an electric dryer cord with a 3 prong plug?

To install an electric dryer cord with a 3-prong plug, first make sure the dryer is unplugged. Then, remove the access panel on the back of the dryer. Connect the green ground wire to the dryer's grounding screw, and the other two wires to the appropriate terminals marked "hot" and "neutral." Tighten the screws securely, replace the access panel, and plug in the dryer. It's important to follow the manufacturer's instructions and consult a professional if needed.


What is the extension cord with 3 prong could be used for?

Depends on the size of the wire in the extension cord. The 3 prong is just the hot, neutral, and ground.


What is wrong if you changed a four prong to a three prong and the dryer is not heating?

My question is WHY did you replace a four prong dryer plug with a three prong! 220 volt Electric dryers require two hot legs, a neutral and a system ground wire. Sounds as though you shunted one of the hots or the neutral. You need to install a four prong plug of the same configuration and wire it exactly as the original.


How do you change a 4 prong cord to a 3 prong cord on dryer?

I needed that answer years ago and was told that the two outer wires are the hot leads and can be interchanged on the two outer lugs on the machine, the center wire is your neutral and needs to be attached to the center lug( the neutral lug on the machine is almost always silver, the hots are brass color) it's really simple once you know,outer to outer, center wire to center lug.


Is the wide side of a 2 prong cord hot or ground?

The wider prong of a 2 prong cord is typically the "hot" wire, meaning it carries the current to power a device. The narrower prong is the ground wire, which provides a pathway for current to safely flow in the event of a fault. It is important to always check the manufacturer's instructions or consult a professional electrician for proper identification and use of electrical cords.


Is it possible to put a 4-prong plug on a dryer that uses a 3-prong plug and how would you do this?

If you are viweing this because you want to change the newer 4-prong plug/outlet to fit an older 3 prong outlet/plug don't do it! The newer plug is safer and the 3 prong plug no longer meets code. See the discussions in other threads. all you need to do is hook the two hot leads on the outer terminals, then the nueatral, white wire on the center terminal and the green ground wire to the ground screw. Be sure to remove the bonding jumper that ties the neutral to the chassis. This is no longer needed as now you have a ground line from the outlet. There should be 3 insulated lugs in the dryer, two hots and a neutral. Connect the red and black wires in your new cord to the hot lugs (red & black are interchangeable), and the white neutral to the neutral lug. Neutral is the center wire on your older 3-wire cord, for reference. Connect the green ground wire directly to the chassis of the sryer using a convienent screw. Use the four prong cord if you can. It is safer because it has the extra ground wire which older cords did not.


Can a dryer have a 2 prong cord?

This could be a trick question. If it is a gas dryer yes. Hot and neutral without a ground. 110 volts to the dryer motor and controls. Heat coming from gas. If it is an electric dryer no. The heater element requires 240 volts. You could get this from black and red. 2 wires the controls require 110 requiring black and neutral. The dryer wouldn't heat ( the electric heating element.) with only 110 volts. In any case no dryer should operate with only 2 wires. It is the third wire or 4th wire that may save you life. That is the equipment ground conductor, that provides a safe path for electricity to return to ground in case of an malfunction. Save the planet, put out a laundry line, and hang your cloths to dry.


How do you convert a 4 prong GE dryer power cord to a 3 prong dryer power cord?

Answer for USA, Canada and countries running a 60 Hz supply service.Check with a local licensed electrician - or your local electrical safety authority - before you do this because it may no longer be legal to convert a 4 prong cord to a 3 prong cord in the place where you live. There were very important safety reasons why 4 prong outlets were brought in instead of the old-fashioned 3 prong outlets, which had neutral connected directly to ground at the appliance.The only safe place to connect the neutral wires in a building to the safety ground wires is upstream of all the circuit breakers and fuses, which means it should only be done inside your main breaker panel, nowhere else.So you can connect your new dryer as safely as possible, the preferred method is to get your existing 3 prong outlet converted to an up-to-date 4 prong outlet which has two hot prongs and a neutral prong plus a separate ground prong.Connect the green and white wires together on the center connection. The black and red wires are connected to the same outside connecters as the 4 wire configuration.For more information see the answers to the Related Questions shown below.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


How can I convert a 3-prong dryer outlet to a 4-prong outlet?

To convert a 3-prong dryer outlet to a 4-prong outlet, you will need to replace the existing outlet with a 4-prong outlet and rewire it according to the new configuration. This typically involves connecting the green wire to the ground terminal, the white wire to the neutral terminal, and the two hot wires to the remaining terminals. It is important to follow safety guidelines and consult a professional if you are unsure about the process.