answersLogoWhite

0

The wooden stick loop is used in the oxidase test because it does not interfere with the reaction by providing catalase activity like metal loops can. Metal loops can catalyze the breakdown of hydrogen peroxide, producing oxygen bubbles that could interfere with the interpretation of the test results.

User Avatar

AnswerBot

1y ago

What else can I help you with?

Continue Learning about Natural Sciences

What is the Lactococcus lactis ssp lactis oxidase test result?

The oxidase test result for Lactococcus lactis ssp lactis is negative. This bacterium lacks the enzyme cytochrome c oxidase that is needed to produce a positive result in the oxidase test.


What is the function of the test reagent in the oxidase test?

The test reagent in the oxidase test contains a substrate that changes color when it is oxidized by cytochrome oxidase, an enzyme present in certain bacteria. The color change indicates the presence of the enzyme, helping to differentiate between oxidase-positive and oxidase-negative bacteria.


Is coryne bacterium is oxidase positive?

No, Corynebacterium species are typically oxidase-negative. This means they do not produce the enzyme cytochrome c oxidase, which is essential for the oxidase test.


Why is it advisable to include a known oxidase-positive control in any test of an unknown organism?

Including an oxidase-positive control in a test of an unknown organism helps to confirm the presence of the enzyme oxidase in the test system. This control provides a baseline for comparison with the unknown organism to determine if it also produces oxidase. This is particularly important in biochemical testing to accurately identify the unknown organism based on its metabolic properties.


Give explanation why the Oxidase test identifies the presence of cytochrome c oxidase and not the other electron carriers?

An oxidase test relies on a reagent that will change colors when it is oxidized. The reagent used in the test only reacts to cytochrome c oxidase by acting in place of oxygen to receive electrons from the cytochrome.

Related Questions

Why should nichrome or iron-containing inoculating devices not be used in the oxidase test?

Nichrome or iron-containing inoculating devices should not be used in the oxidase test because they can introduce false-positive results. The metal ions from these devices can react with the reagents used in the oxidase test, leading to the appearance of a positive result even if the organism being tested is actually negative for oxidase activity. It is important to use a non-reactive, disposable inoculating loop or swab to avoid interference with the test results.


What is the precautions in oxidase test?

Here's some of the precautions: A time limit must be set for observing the colour change, a sterile wooden stick/platinum loop must be used, store the oxidase paper at ~4 degree Celcius and in a dry state. Also, place the test paper on a glass slide. Lastly, the test paper should be discarded to the disinfectant


What is the Lactococcus lactis ssp lactis oxidase test result?

The oxidase test result for Lactococcus lactis ssp lactis is negative. This bacterium lacks the enzyme cytochrome c oxidase that is needed to produce a positive result in the oxidase test.


What is the function of the test reagent in the oxidase test?

The test reagent in the oxidase test contains a substrate that changes color when it is oxidized by cytochrome oxidase, an enzyme present in certain bacteria. The color change indicates the presence of the enzyme, helping to differentiate between oxidase-positive and oxidase-negative bacteria.


Is the media for oxidase test selective or differential?

The media for oxidase test is differential, not selective. It helps differentiate between bacteria that produce the enzyme cytochrome c oxidase (positive result) and those that do not (negative result).


Is coryne bacterium is oxidase positive?

No, Corynebacterium species are typically oxidase-negative. This means they do not produce the enzyme cytochrome c oxidase, which is essential for the oxidase test.


Why is it advisable to include an oxidase-positive control organism in any test of an unknown organism?

It's advisable so that the oxidase test determines whether or not an organism has cytochrome oxidase in its electron transport chain.


The oxidase test is used to differentiate among which groups of bacteria?

The oxidase test is used to differentiate bacteria based on their ability to produce cytochrome c oxidase enzyme. It helps to differentiate between oxidase-positive bacteria, such as Pseudomonas and Neisseria, and oxidase-negative bacteria, such as E. coli and Enterococcus.


Does E. coli test positive for oxidase?

no


What is another test used for the identification of Staphylococcus aureus?

oxidase test.


Why is it advisable to include a known oxidase-positive control in any test of an unknown organism?

Including an oxidase-positive control in a test of an unknown organism helps to confirm the presence of the enzyme oxidase in the test system. This control provides a baseline for comparison with the unknown organism to determine if it also produces oxidase. This is particularly important in biochemical testing to accurately identify the unknown organism based on its metabolic properties.


Give explanation why the Oxidase test identifies the presence of cytochrome c oxidase and not the other electron carriers?

An oxidase test relies on a reagent that will change colors when it is oxidized. The reagent used in the test only reacts to cytochrome c oxidase by acting in place of oxygen to receive electrons from the cytochrome.