Yes. The output of your generator will be about 42 amps.
Installation of this transfer switch is an area where a wrong connection could go very wrong with devastating results.It is a complicated job in as much as you have to know wire sizes, ampacity of wires and proper electrical workmanship. Such a project should be left to a licensed electrical contractor to take out the proper permits and call for proper inspections. By taking this route it will leave you confident that if any mishaps happen to the installation down the road your insurance company will be behind you 100%.


See related links below.

Before you do any work yourself,
on electrical circuits, equipment or appliances,
always use a test meter to ensure the circuit is, in fact, de-energized

IF YOU ARE NOT REALLY SURE YOU CAN DO THIS JOB
SAFELY AND COMPETENTLY
REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Wiki User

15y ago

What else can I help you with?

Continue Learning about Natural Sciences

What is a good option for a generator that can put out 100 kW everyday and be easily hooked up to a house?

Your specifications of the equipment need to be stated. Voltages and amperage of the generator. Whether the house needs to be on a transformer from the generators output. Is the house now on utility power and you want the generator to be switched to standby power. Automatic transfer switch or manual transfer switch. A 100 kW generator seems pretty big to operate for just a home. Generator engines (prime mover) like to be operated at close to maximum output and a half loaded generator will not make the engine work hard enough. The generator has to be sized to the load. There are too many variables to give a complete answer. If you go to the discussion tab and open a dialogue I will be glad to discuss this with you.


Can you use a 30 amp standby generator to power a 20 amp transfer switch?

Yes, as long as there is fusing between the generator and the transfer panel. This fuse can be no larger than 20 amps. Without this fuse the load that the transfer panel is handling could go as high as the generator output (30 amps) which is a current that the transfer panel is not rated for.


Can you connect a 30 amp generator to a 20 amp transfer panel?

Yes, as long as there is fusing between the generator and the transfer panel. This fuse can be no larger than 20 amps. Without this fuse the load that the transfer panel is handling could go as high as the generator output (30 amps) which is a current that the transfer panel is not rated for.


What cable is needed to go from a generator to the electrical supply?

The cable that is used to connect from the generator is based on the size in kW's of the generator and the generator's breaker size rated in amps. It usually is a flexible cab-tire 4 wire cable if the generator is a portable type. If it is a stationary generator is has to be wired with a flexible conduit so as not to transmit vibration from the generator to the conduit system.


Is it legal to use a gas generator to power a home - what are the codes and standards?

No buy a transfer switch and wire it direct to your panel.

Related Questions

What Is Automatic Transformer SwitchATS?

A transfer switch, in general, switches load between two sources. An automatic transfer switch or ATS is usually installed where a generator is located to allow the generator to give power while electricity is out.


Where would one use an automatic transfer switch?

An automatic transfer switch would be used when one needs to switch energy from one source to another and cannot do it manually. It can be used to switch from electric to a generator when needed.


What is a generator transfer switch used for?

A generator transfer switch is used to switch an electrical load between different sources such as grid power and a standby generator or between multiple generators to allow for maintenance of a generator in a set. These switches can be automatic, switching between sources when a source fails or moves out of specification or they can be manual, requiring operator intervention.


Can a portable generator be installed inside a motorhome?

Yes it can. Things to consider would be the fuel source, how to safely deal with the exhaust, and the transfer switch. I would recommend an automatic transfer switch.


What size wire do you need going from a 20KW 83A generator to the main 200A automatic transfer switch?

In conduit? direct burial? distance?


Generator Transfer Switch?

form_title= Generator Transfer Switch form_header= Keep your generator running with a transfer switch. What is the brand and model of your generator?*= _ [50] How old is your generator?*= _ [50] Do you need someone to install the switch?*= () Yes () No


What are the different types of low voltage transfer switches available?

There are a few different types of low voltage transfer switches available, including manual transfer switches, automatic transfer switches (ATS), and generator transfer switches. Manual transfer switches require the user to manually switch between power sources, while ATSs can automatically detect and switch to an alternate power source. Generator transfer switches are specifically designed for use with generators and will automatically detect when a generator is running and switch the load to that source of power.


What is an ats panel?

Automatic transfer switch An ATS (Automatic Transfer Switch) is an expensive auxiliary piece of equipment and depending on the standby situation, is not always used. In emergency situations when a power failure occurs certain establishments need instant recovery from no power. Hospitals, town water distribution systems fall into this category. Some of the less priority recovery establishments will use a manual transfer switch. This is where the operator will start the generator and then transfer the utility incoming power to the generator power to feed the load. Then you have the home owner generator that just needs the pull of a handle to start the generator and you just plug in the load. So to answer the question, not all generators need to be connected to an ATS; it depends on the situation the generator is used for.


What are the key features and benefits of a 100 amp automatic transfer switch?

A 100 amp automatic transfer switch is a device that automatically switches power sources during a power outage. Its key features include the ability to seamlessly transfer power from the main grid to a backup generator, ensuring uninterrupted power supply. The benefits of a 100 amp automatic transfer switch include increased reliability, convenience, and peace of mind during emergencies.


Can you design a microcontroller program for a three phase automatic generator changeover on main load failure?

This circuitry is already in the market place. It is in the form of an ATS (automatic transfer switch). The controller is pre programmed for sensing and switching. Customer input is limited to setting of the timing of the relays in the transfer switch.


How does a automatic transfer switch work?

The load have deference two feeder like transformer &generator when the power of transformer shutdown the load get power from second feeder generatoraoto


What is the recommended wiring diagram for a generator transfer switch?

The recommended wiring diagram for a generator transfer switch involves connecting the generator to the transfer switch using designated wires to ensure safe and efficient power transfer during an outage.