  • Temperature Variation - This can be one of the major causes of error in a strain gauge. It can easily change the gauge resistance and cause differential expansion between the gauge and the test piece, causing variation in the measurable strain.
  • Humidity - Humidity can affect the accuracy by the breakdown of insulation between the gauge and the ground point. It also causes electro-chemical corrosion of gauge wire due to electrolysis.
  • Small errors could be caused due to thermoelectric effect.
  • The gauge will be erroneous even due to small factors like zero drift, hysteresis effect and so on.
  • Magnetostrictive effect can also cause errors in strain gauges of ferromagnetic materials. It produces a small voltage fluctuation of almost 2 mill volts.
User Avatar

Wiki User

11y ago

What else can I help you with?

Continue Learning about Physics

What are factors affecting accuracy of strain gauges?

Factors affecting the accuracy of strain gauges include temperature fluctuations, mechanical stress on the gauge, incorrect mounting techniques, and electrical noise interference. These factors can lead to variations in the resistance of the strain gauge, impacting the accuracy of the strain measurement.


What are the uses of strain gauges in measuring mechanical deformation?

Strain gauges are used to measure mechanical deformation in various applications such as structural testing, material testing, and stress analysis. They are commonly used in industries like aerospace, automotive, and civil engineering to monitor the strain and stress levels in structures and components. By detecting changes in resistance caused by deformation, strain gauges provide valuable data for evaluating the performance and safety of materials and structures.


What is the problem can be for load cells?

Some potential problems with load cells include drift in calibration over time, damage to the strain gauges due to overloading or shock loading, electrical noise interference affecting readings, and incorrect installation causing misalignment or instability. Regular calibration, proper handling, shielding against electromagnetic interference, and careful installation can help mitigate these issues.


What is the Difference between strain gauge and extensometer?

Strain gage and Extensometer both are same purpose to check the stress and strain in selective test pieces, but traditional they were using strain gage its take the preparation time is high and Extensometer we are check the directly both results are same.


What are the key factors to consider when analyzing the theoretical strain in a cantilever beam?

When analyzing the theoretical strain in a cantilever beam, key factors to consider include the material properties of the beam, the applied load or force, the beam's dimensions and geometry, and the boundary conditions at the fixed end of the beam. These factors help determine how much the beam will deform under stress and how much strain it will experience.

Related Questions

What are factors affecting accuracy of strain gauges?

Factors affecting the accuracy of strain gauges include temperature fluctuations, mechanical stress on the gauge, incorrect mounting techniques, and electrical noise interference. These factors can lead to variations in the resistance of the strain gauge, impacting the accuracy of the strain measurement.


Difference betwwen bounded and unbounded strain gauge?

Bounded strain gauges are designed to operate within a specific range of strain, providing accurate measurements only within that limit, while unbounded strain gauges can theoretically measure strain without a predefined limit, allowing for broader applications. Bounded gauges typically feature a protective element that restricts their range, ensuring reliability and precision under controlled conditions. In contrast, unbounded strain gauges may be used in scenarios where extreme strains are expected, though they may sacrifice some accuracy and stability. The choice between the two depends on the application requirements and the expected strain conditions.


Difference between unbonded strain gauge and bonded strain gauge?

The essential difference is that the bonded strain gauges are bonded on to the specimen whose strain is being measured whereas the unbonded strain gauges are not bonded on to the specimen. As the bonded strain gauges are well bonded on to the specimen, the entire strain being experienced by the specimen is transferred to the strain gauge. However, the bonded strain gauges are affected by temperature changes and also due to transverse strains.For transverse strains and ambient temperature compensations, suitable circuits for compensation can be used using Wheatstone's bridge. The unbonded strain gauges cannot transfer the strain of the specimen to the strain gauge and hence it is used mainly for displacement, or pressure or force transducers. It is least affected by transverse strain and temperature compensation of unbonded gauges cis automatically eliminated using Wheatstone's bridge.


Describe metallic bonded strain gauges?

metallic bonded strain gauge


What are the advantages and disadvantages of mechanical strain gauges?

Babalo


What is the purpose of a strain gauge?

A strain gauge is used to measure the strain of an object. It was invented by the inventors Edward Simmons and Arthur Ruge in 1938. There are several types of gauges (metallic, capacitance, photo-electrics and semiconductor gauges).


How do you calibrate strain gauges?

The strain gage indicates strain, and the stress is from Hooke's law; stress = modulus times strain so you need to know the modulus of elasticity


Where is constantan used?

In many typical installations, it is used in strain gauges.


What are the uses of strain gauges in measuring mechanical deformation?

Strain gauges are used to measure mechanical deformation in various applications such as structural testing, material testing, and stress analysis. They are commonly used in industries like aerospace, automotive, and civil engineering to monitor the strain and stress levels in structures and components. By detecting changes in resistance caused by deformation, strain gauges provide valuable data for evaluating the performance and safety of materials and structures.


What is the inductance of Mechanical strain gauge?

"Mechanical Strain gauges" do not have inductance. There are many types of strain gauge: Mechanical, photoelastic, electrical etc.... Are you wanting the inductance of an electrical strain gauge? if so which type?


What has the author John Yarnell written?

John Yarnell has written: 'Resistance strain gauges'


What is the example of zero order instrument?

Wire strain gauges are an example for a zero order instrument.