answersLogoWhite

0

The limitation of the wheatstone is that it may give inaccurate readings if not balanced.

User Avatar

Wiki User

11y ago

What else can I help you with?

Continue Learning about Physics

What did Charles wheatstone inventions?

Charles Wheatstone invented the concertina, a small musical instrument similar to an accordion. He also invented the Wheatstone Bridge, a device used to measure electrical resistance accurately. Additionally, Wheatstone contributed to the development and improvement of the telegraph system.


What is Difference between ohmmeter and Wheatstone's bridge?

An ohmmeter is a device used to measure the resistance of a component or circuit by passing a current through it and measuring the voltage drop. In contrast, a Wheatstone's bridge is a circuit used to measure an unknown resistance by balancing it against known resistances in a bridge configuration, without passing a current through the unknown resistor. Wheatstone's bridge is more accurate for precise resistance measurements compared to an ohmmeter.


Compare the accuracy of the wheatstone and kelvin double bridge?

The Kelvin double bridge is more accurate than the Wheatstone bridge because it eliminates errors associated with lead resistance and contact resistance in the circuit. The Kelvin bridge uses four terminals to independently measure and compensate for these errors, resulting in more precise resistance measurements.


What happens when unknown resistance is changed to other armin wheatstone bridge?

Changing the unknown resistance in a Wheatstone bridge will result in an imbalance in the circuit, causing a potential difference across the bridge. This potential difference can be used to determine the new value of the unknown resistance by adjusting other known resistances until the bridge is balanced again.


Why galvanometer is connected in wheatstone bridge?

A Wheatstone Bridge is used to measure resistance of an electrical / electronic component. The galvanometer (which was used to measure voltage) has now been replaced by the Multimeter.Both are not used today.AnswerA Wheatstone Bridge has most definitely NOT been replaced by a multimeter! It uses a completely-different method of measuring resistance and is significantly more accurate than a multimeter. The purpose of the very sensitive galvanometer is to detect when the Bridge circuit is 'balanced', by sensing the current (not voltage!) passing through it. When no current flows, the Bridge is balanced.

Related Questions

Why using wheatstone bridge in transducer?

You use a transducer in a wheatstone bridge. The wheatstone bridge allows you to find an unknown resistance.


How do you troubleshoots?

with a wheatstone bridge


How does the Kelvin bridge differ from the wheatstone bridge?

kelvin's bridge is the modified version of wheatstone bridge and used to measure resistance values less than 1 ohm.


What is Wheatstone's bridge?

The wheatstone bridge is an instrument used to measure electrical resistance by means of balancing a bridge circuit. The bridge circuit contains two legs, one of which contains the unknown resistance. Variations in wheatstone bridge can be employed to measure inductance, capacitance, and impedance also.


How do you troubleshoot galvanometer?

with a wheatstone bridge


At what condition the voltmeter connected across the wheatstone bridge will be zero?

At a balanced condition the voltmeter connected across the wheatstone bridge will be zero.


What is a Wheatstone?

The wheatstone bridge is an instrument used to measure electrical resistance by means of balancing a bridge circuit. The bridge circuit contains two legs, one of which contains the unknown resistance. Variations in wheatstone bridge can be employed to measure inductance, capacitance, and impedance also.


Why a wheatstone circuit is called a bridge?

An electrical circuit used to measure an unknown electrical resistance is called a Wheatstone bridge. It is called a bridge because it balances two legs of a bridge circuit.


What is the conclusion for the wheatstone bridge experiment?

This lab effectively showed how the Wheatstone bridge provides a mechanism to calculate an unknown resistance using the known relationships given through the resistivity correlation to length. It demonstrated how to set-up a Wheatstone bridge and how to manipulate a Wheatstone bridge in a laboratory setting. In addition, the lab provided a demonstration of the aforementioned linear relationships. Although significant error existed in this lab, the results still reflect the relationships governing the Wheatstone bridge sufficiently for understanding in an experimental contextual environment unknown resistance using the known relationships given through the resistivity correlation to length.It demonstrated how to set-up a Wheatstone bridge and how to manipulate a Wheatstone bridge in alaboratory setting. In addition, the lab provided a demonstration of the aforementioned linearrelationships. Although significant error existed in this lab, the results still reflect the relationships governing the Wheatstone bridge sufficiently for understanding in an experimental contextual environment


Where in the car is a wheatstone bridge?

sound system


What is the difference between Wheatstone bridge and meter bridge?

WHEATSTONE BRIDGE : A wheatstone bridge is used to measure an unknown electrical resistance by balancing two legs of a bridge circuit, one leg of which includes the unknown compound.Its operation is similar to the original potentiometer. METER BRIDGE : A uniform resistance wire 1 meter in length, mounted above a scale marked in millimeters, with terminals added to make the device usable as either part of a wheatstone bridge or of a potentiometer.


What are the application of Wheatstone bridge?

to measure the unknown resistance