It depends on the laws of your state or country. I would say, to be safe, inspect the gas line and install the same type of fittings you find there.

User Avatar

Wiki User

14y ago

What else can I help you with?

Related Questions

Can you use galvanized connections on gas iron pipe?

Most codes do not allow Galvanized piping/fittings on gas piping. I have used galvanized pipe/fittings on exterior gas piping before in the state of Michigan but other states do not allows this. Check with your local code authorities.


What is the stencil for on pipe fittings and what do they mean?

Stenciling is used to identify the direction of flow and what the piping is used for such as fire supression ,gas , potable water ,etc


Can you use compression fittings on natural gas pipes?

No. You can use flared fittings with a flaring tool and soft copper pipe.


What materials are suitable for forming gas piping or dissociated ammonia gas piping?

Piping material used for forming gas would be 316L stainless steel.


What are compression fittings used for?

Compression fittings are used to join two tubes or pipes together. Typically it is used when the two pipes are different materials or different sizes. They are also sometimes used on pipes where it is difficult to solder or maybe dangerous to do so.


Is it better using welded fittings or threaded fittings on 2 inch piping for inert gas distribution networks?

If you have a lot to install i would weld. 2 in. is a very big pipe to screw together


Are cast iron fittings used for gas?

Yes, cast iron fittings can be used for gas applications, particularly in older installations. They are durable and resistant to corrosion, making them suitable for handling gas. However, modern installations often prefer materials like steel or brass due to weight and ease of installation. Always ensure compliance with local codes and regulations when using any materials for gas piping.


Can you use soldering copper pipe fittings for gas?

It is not a good idea to use copper pipe with natural gas as any sulphur compounds in the gas can cause an oxide to form in the copper pipe. Often copper is used with propane. In these instances, soft copper tubing is usually used with compression fittings. The tools required are, pipe cutter and 2 wrenches.


Can you use copper sweat fittings for helium?

Yes, copper sweat fittings can be used for helium gas applications, provided that the fittings are properly designed and rated for the specific pressure and temperature conditions involved. It's important to ensure that the joints are well-soldered to prevent leaks, as helium is a small molecule that can escape easily. Additionally, always check local codes and regulations regarding materials used for gas piping to ensure compliance.


Do you need a permit to move a gas water heater in springfield mo?

If you are moving or adding on to gas pipes and fittings, it is highly recommended to get a gas permit. If there happens to be a failure on the additional piping your insurance will not cover it if your house blows up!


Can type L copper poison you when used for medical gas?

No it will not poison you. Copper piping is used extensively in Medical Gas applications. "TYPE L" signifies the wall thickness of the piping.


What is the best for gas usage brass fitting or black iron fitting?

Brass is normally used for the gas connector to an appliance and for small shut off valves Piping and related fittings black steel is used ABOVE Ground in on piping not exposed to excessive moisture