answersLogoWhite

0

i have been doing it for a good number of years. as long as your on-off switch is working. if switch mess's up, you could burn out the pump. now I'm taking about about basic home owner pumps that only cost 150.00 to 200.00 dollars.

User Avatar

Wiki User

12y ago

What else can I help you with?

Related Questions

What is thermo overload on a sump pump?

It is an over heat protection to prevent pump windings from buring out


What is used for overload protection in a hydraulic system?

A relief valve is installed in the system, often in the pump itself, to relieve (not prevent) any overpressurization of the system.


What are the key features and functions of a pump control box?

A pump control box is a device that regulates the operation of a pump. It typically includes features such as on/off switches, pressure sensors, and overload protection. The main functions of a pump control box are to start and stop the pump automatically based on water levels or pressure, protect the pump from damage, and provide diagnostic information about the pump's performance.


Can you use normal relay to start a single phase motor pump?

It depends on what your definition of a normal relay is. If it is a small plug in relay to control the motor's contactor then there is no point. All pump motors need control to start and stop the pump. Whether it is done from a pressure switch or a float system it doesn't matter they both should control the motor's contactor and not the pump directly. Most small relays do not have the amp capacity in their contacts to handle inductive loads. Using a motor contactor also has the benefit to protect the motor with overload protection. Using the overload contacts in series with the control device allows the pump to go off line should an overload occur.


What are the key features and functions of a submersible pump control box?

A submersible pump control box is a device that regulates the operation of a submersible pump. Its key features include monitoring water levels, controlling pump start and stop functions, and protecting the pump from damage. The control box also typically includes overload protection, voltage monitoring, and diagnostic indicators to ensure proper pump operation.


Your 1982 Cadillac Deville keeps burning fuel pump fuses you already replaced the fuel pump and fuel pump relay.?

Overload or short in wiring?


How do you wire a pump start relay for 220 volts?

Assuming that your pump start relay is a contactor with overload protection and a 220 volt coil. Connect the incoming 220V to the connection points on the top of the contactor. Connect the pump motor to the bottom contactor connection points. From the right incoming voltage connection point take a # 14 wire, in flexable conduit, to one of the N.C. (normally closed) terminals in the pressure switch. The pressure switch which should be connected into the water line at this time on the pressure side of the pump. From the opposite N.C. terminal in the pressure switch take another # 14 wire, in the same flexable conduit, to one side of 220V contactor coil. At this point, (1) if overload contacts are available, take a # 14 wire from the other side of the 220V contactor coil to one side of the N.C. contacts in the overload block. From the opposite side of the N.C. contact in the overload block take a # 14 wire up to the left side of the incoming 220V connection point. If there is no overload block, as some motors have internal overload protection, (2) take a # 14 wire from the other side of the 220V contactor coil directly to the left side of the incoming 220V connection point. As you can see the circuit is all series connections from voltage supply to pressure switch, to overloads, to return voltage supply. With the pressure switch contacts closed and the overload contacts NOT tripped the pump will start. When pressure reaches the set point the switch will open and the pump will shut off.


How can I choose the best inverter for my sump pump to ensure reliable backup power during emergencies?

When selecting an inverter for your sump pump, consider the power requirements of the pump and choose an inverter that can handle that load. Look for a pure sine wave inverter for reliable power output. Ensure the inverter has overload protection and automatic shutdown features to protect both the pump and the inverter during emergencies.


Why the cep of thermal power plant is made verticle?

virticle pump has better effisiency then horigental pump. it requirslower nhpc.


Can an Oscar live without a pump?

Yes, can they live without air pump?


Why my 1992 190e blown overload protection relay as soon as you trun key?

If your 1992 Mercedes-Benz 190E's overload protection relay blows as soon as you turn the key, it may indicate a short circuit in the electrical system, possibly due to damaged wiring or a faulty component. Another possibility is that there is a malfunctioning device connected to the circuit, such as a failing fuel pump or ignition coil. Inspecting the wiring and components related to the relay circuit can help identify the source of the problem. It's advisable to consult a professional mechanic for a thorough diagnosis and repair.


Does water pump has ground fault protection?

A stand alone water pump does not have ground fault protection within the motor body. The ground fault protection has to come from equipment that is situated upstream from the pump. It can be in the form of a GFI breaker that supplies the voltage to the pump. Larger size pumps usually use a stand alone GFI that is hard wired to the supply breaker and then the pump is hard wired to the GFI unit.