answersLogoWhite

0

If local Plumbing code allows it, use it for drain and vent lines.

User Avatar

Wiki User

14y ago

What else can I help you with?

Related Questions

Properties of copper pipe used by a plumber?

Most plumbers today no longer use coper "pipe" or TP copper as the cost is to high=What plumbers and HVAC and other trades use is Copper tubing types K, L, M, DWV, ACR=


How can I attach PEX tubing to copper pipes?

To attach PEX tubing to copper pipes, you can use a fitting called a PEX-to-copper adapter. This adapter allows you to connect the PEX tubing to the copper pipe securely using crimp or clamp fittings. Make sure to follow the manufacturer's instructions and use the appropriate tools for a proper and leak-free connection.


How can you use the copper in your home?

for electric / heating / DWV / domestic potable water supply


How can I connect PEX tubing to copper pipes in a plumbing system?

To connect PEX tubing to copper pipes in a plumbing system, you can use a fitting called a PEX-to-copper adapter. This adapter typically has a PEX side that can be crimped or clamped onto the PEX tubing, and a copper side that can be soldered or connected using a compression fitting to the copper pipe. Make sure to follow the manufacturer's instructions and use the appropriate tools for a secure and leak-free connection.


What is the best way to connect PEX tubing to copper piping using a PEX to copper adapter?

The best way to connect PEX tubing to copper piping using a PEX to copper adapter is to first cut the PEX tubing to the desired length and then slide the PEX fitting onto the tubing. Next, use a crimping tool to secure the fitting onto the tubing. Finally, solder the copper adapter onto the copper piping and connect the PEX fitting to the copper adapter.


How can I connect PEX tubing to copper pipes?

To connect PEX tubing to copper pipes, you can use a fitting called a PEX-to-copper adapter. This adapter has a PEX side that can be crimped onto the PEX tubing and a copper side that can be soldered onto the copper pipe. This creates a secure and watertight connection between the two types of pipes.


What is the recommended size of tubing for propane use, specifically 1/2 copper tubing?

The recommended size of tubing for propane use, specifically 1/2 copper tubing, is typically sufficient for most residential propane applications. It is important to consult with a professional to ensure proper sizing and installation for safety and efficiency.


What are the best practices for connecting PEX tubing to copper fittings?

The best practice for connecting PEX tubing to copper fittings is to use a proper transition fitting specifically designed for this purpose. This fitting will ensure a secure and leak-free connection between the two materials. It is important to follow the manufacturer's instructions and use the appropriate tools to make the connection correctly.


Can you put copper piping to galvanized piping?

Yes, this happens quite often in older houses, copper pipe can be threaded; thus one can join them and there are several fittings that can be utilized.On the other hand, copper tubing (K, L, M, and DWV) can be joined depending on which of the following application method is used:For copper tubing to galvanized water supply, one would use a dielectric nipple or union to prevent electrolytic action from taking place or dezincification of the galvanizing pipe.If these lines are for waste or venting, the Mission Rubber Company LLC has various types of couplings that can go from tubing OD to pipe OD without the dangers of mixing ferrous and nonferrous metals .For copper tubing to IPS you can solder, braze a male adapter and use the dielectric union, use a copper x galvanized dielectric union, or copper by female adapter and a dielectric nipple .If your connecting to a Durham system and the galvanized pipe has a Tucker coupling or a Kennedy tee wye, then you can use lead and oakum without the fear of mixing dissimilar metals as the lead is nonferrous metal but has no adverse effect with galvanized or copper pipes.


When should you use joint compound on copper pipes?

=== === By the way I doubt very seriously your using copper pipes your using copper TUBING


How can I efficiently replace a copper pipe with PEX in my plumbing system?

To efficiently replace a copper pipe with PEX in your plumbing system, follow these steps: Turn off the water supply to the area where you will be working. Cut the copper pipe using a pipe cutter. Clean the ends of the copper pipe and PEX tubing. Install the appropriate fittings to connect the PEX tubing to the existing plumbing. Use a crimping tool to secure the connections. Turn the water supply back on and check for leaks. Insulate the PEX tubing if needed.


What solder do you use on copper tubing for plumbing?

Copper tubing solder "Solder" is an erroneous term as solder mean lead which of course is banned (safe water drinking act) Sweating is another term for "soldering" Copper can be joined by various alloys such as 95 % tin -5% Anatomy or one of the many silver bearing types of low temperature alloys. For the strongest possible joints brazing is the best way to go with a tensile strength over 87,000 PSI compared to soft solder joints of 16,000 PSI For DWV copper joints one can use one of the lead tin solders such as 50 -50 as it is quite easy to work woth.