Because everyone deserves the American dream of Sharing the wealth thus a decent Plumbing helper would make $25 per hr in the envelope and then there is health insurance and liability insurance and workmans comp ins and over head and profit . Being a "citizen of the world" it is your democratic duty to never ever complain no matter how much it cost to hire someone .. Just pay the bill and be thankful

User Avatar

Wiki User

16y ago

What else can I help you with?

Related Questions

Can Black steel pipe be replaced with Galvanized piping for gas piping?

galvanized piping is acceptable but not necessary. all steel piping must be wrapped when entering ground at least 6" (a foot is better) bushings are not allowed unless properly peened so its better to just use bell reducers. and finally be sure to size your pipe according to the BTU requirement of the appliance being serviced


What is ferrous piping?

Ferrous piping refers to piping made from iron or steel, which are both ferrous metals. These types of piping are commonly used in industrial and commercial applications due to their strength and durability. However, they are susceptible to corrosion, so appropriate protective measures such as coatings or cathodic protection may be necessary.


Is it better to use galvanized or black iron pipe when piping LP gas in a outside application?

Galvanized for water, black for gas. You can always paint the black if you are worried about it rusting. That would depend on local codes as many do not allow the use of galvanized and other codes state "where moisture is present galvanizing coating shall be applied. There is no one code that fits all as some codes follow OSHA guide lines when it comes to color coding of piping so painting black is NOT always an option


How can you prevent galvanic corrosion between 304 stainless steel piping and galvanized saddle tap fittings?

Completely isolate the electrical circuit - so use some insulation such as PVC to ensure the metals are not in contact - but the above situation should not be allowed in the first place - very poor design indeed.


Is galvanized metal on ferrous?

Yes, galvanized metal is typically made from iron or steel, so it is ferrous. The metal is coated with a layer of zinc to protect it from rust and corrosion.


How can I replace my water piping with PEX piping?

Well, I would recommend contacting Home Depot or Rona so they could send a skilled professional to help replace the water piping in basements using PEX piping. They also offer that service and other services related to this topic, for an incredibly reasonable price.


How can you melt a galvanized nail?

well galvanized metal is nothing more than zinc coated steel. Zinc melts at 787.1 F and steel melts at roughly 1200 F depending on the quality of the steel. So yes you can melt a galvanized nail.


Will a magnet stick to galvanized steel?

Yes, a magnet will stick to galvanized steel. Galvanized steel is steel that has been dipped in molten zinc so it comes out with a zinc coating. (The zinc coating inhibits corrosion.) A magnetic can "reach through" this coating and stick to the steel.


Why is renewable energy not so commercialized?

Renewable energy is not so commercialized because it is too expensive. If you were to place enough solar panels on your roof to be able to just use solar energy, you need ten years worth of time in order to make the electric bills the same, and that does not include the expensive batteries that need replacing!


Will steam cause galvanized pipe to corrode?

Water does, so I am pretty sure steam will


What is the purpose of a bender conduit?

A conduit blender is a tool that is used to bend conduit piping. This allows electricians to bend conduit piping around corners so that they do not have to use connector joints.