There are two pumps the primary and the secondary pump. The primary is the chilled water pump which is what pumps cold water throughout the building and the secondary circulates the water.

User Avatar

Wiki User

11y ago

What else can I help you with?

Related Questions

What is the chilled water pump operation?

poos


What does the abbreviation CHW in HVAC?

It stand for commercial hot water... u may also interested in CHP---Combined heat and power CWP-- Condenser water pump CW - Chilled water pump


How do you calculate chilled water system volume if knowing chiller capacity?

just multiply pump capacity by 3


Why you have to connect the pressurization unit pipes to the pump suction of the chilled water pump and not to discharge header?

As the chilled water system is a close system and basically consist of two loops i.e one loop from pump discharge to load & second loop from load to pump suction.Now,the effect of pressure drop will be more prominent in the second loop ,after the flow exit the load.Hence we have to alleviate the pressure where the effect of pressure loss & small water requirement is more prominent and i.e the suction side of the pump.


Where you put air separator in chiller?

at end of the chilled water return header, before entering in to suction of the primary pump and chiller anand


Flow diagram of chilled water system?

You are probably referring to Absorption refrigeration. Try Google.


How chilled water system work?

Um, try this site to know: http://www.engineeringtoolbox.com/chilled-water-d_955.html .


Formula for kwowing chiller tonnage?

Chilled water flow in gpm x difference in chilled water temperature/24


What is a system that uses heat to create chilled water?

A chiller system uses heat to create chilled water by transferring heat from the water to a refrigerant, which then circulates to reject the heat to the outside environment. The chilled water is then used for air conditioning or refrigeration purposes.


Why are primary chilled water pumps smaller than secondary pumps?

PRIMARY CHILLED WATER PUMPS ARE SELECTED TO FULFILL THE REQUIREMENTS OF THE CHILLER WHERE AS SECONADRY CHILLED WATER PUMPS TO SUPPLY CHILLED WATER TO THE LOAD. FOR EXAMPLE TO THE FAN COIL UNITS & AIR HANDELING UNITS. IN NORMAL PRACTICE THE SECONDARY CHILLED WATER PUMPS ARE APPLIED WITH VARIABLE FREQUENCY (SPEED) DRIVE WHILE PRIMARY WITH CONSTANT SPEED, IN THIS ALSO PRIMARY CHILLED WATER PUMPS CAN BE USED WITH VFD SYSTEM. AIJAZ AHMED JALBANI MECHANICAL ESTIMATION ENGINEER EMIRATES TECHNICAL & THERMAL SYSTEMS L.L.C


What is the material of pipes for chilled water?

my back hair


How do you replace the water pump on an arkla servel heater?

there are types of A/S units that have both heating water pumps and chilled water pumps in the same unit. specifically model # AYB 60-180. Your question needs to be more specific. I have a repair manual.