No. Line voltage is 120v or some multiple there of. It is the potential that comes in from the grid and is found on the hot conductor in your house wiring. 24 volts is "low voltage" and tends to be used only for switching and lighting. Also, 24 volts is often DC (though not always) while line voltage is invariably AC
A circuit is designed to work at a specific voltage and that voltage only.
Phase to Phase voltageCorrection to the above answer:There is no such thing as a 'phase-to-phase' or 'phase-to-ground' voltage. The correct terms are 'line-to-line' (or 'line voltage') and 'line-to-ground' (or 'phase voltage'). Transmission-line voltages are line-to-line (or 'line') voltages.
A voltage is applied to a signal line. The voltage of the line changes gradually from 0 to +V. The "edge speed" is the rate of change of voltage of the line. A voltage is applied to a signal line. The voltage of the line changes gradually from 0 to +V. The "edge speed" is the rate of change of voltage of the line.
20.4 volts.
The term, 'unbalanced system' refers to an unbalanced load. Under normal circumstances, an unbalanced load leads to unbalanced line currents. The line voltages are determined by the supply and remain symmetrical, even when the load is unbalanced. As your question refers to a 'line to neutral' voltage (i.e. a phase voltage), you must be referring to a star (wye) connected load, in which case the phase voltage (line to neutral voltage) is 0.577 (the reciprocal of the square-root of 3) times the line voltage (line to line voltage).
Phase, if you are referring to line, as power line from pole.
the voltage between 1 line & phase =120v The voltage between 2 line =240
In a 3 phase system, the voltage measured between any two phase is called line to line voltage.And the voltage measured between line to neutral is called phase to neutral (line to neutral) voltage.AnswerThere is no such thing as a 'phase-to-phase' or a 'phase-to-neutral' voltage. The correct terms are 'line-to-line' and 'line-to-neutral'.The voltage between any two line conductors is called a line voltage.In a three-phase, three-wire, system, the line voltage is numerically equal to the phase voltage.In a three-phase, four-wire, system, the voltage between any line conductor and the neutral conductor is called a phase voltage. The line voltage is 1.732 times larger than the phase voltage.
A: Any zener connected in series will have each voltage added to the load. Therefore each will add 8 volts to the sum of 24 volts. there will be available at each junction as 8v 16v and finally 24volts
To match 2 phase line voltage it has to be the same voltage.
Line regulation is a measure of the ability of the power supply to maintain its output voltage given changes in the input line voltage. Line regulation is expressed as percent of change in the output voltage relative to the change in the input line voltage.
From line-to-line (any two of the three leads) voltage or 'line voltage', the voltage is 208 V. The line-to-neutral (one of the three leads and the neutral conductor), or 'phase voltage', is 120 V.