If you need to ask this, might I suggest an electrician? There is serious power in the box. Answer for USA, Canada and countries running a 60 Hz power supply service. Shut the main breaker off and use a battery light source to see what you are doing. After removing the panel cover you will be able to see what type of breakers are in the panel. There are two types, push-in or bolt-in. Shut the breaker you want to change-out to the off position. Remove the load wire from it. If the breaker is a push-in type, pry with moderate pressure to the side of the panel while lifting up on the breaker. If it is a bolt-in type just unscrew it from the bus bars. Install your new breaker: with a push-in breaker seat it firmly onto the bus with a hard push. With a bolt-in beaker a bit of caution should be taken not to cross-thread the screw into the bus. If this connection is not tight, arcing could result. Over time this connection could fail and may cause the panel to be changed out due to bus failure. Don't over torque the screw. Replace the load wire and cover and you are done. SAFETY ADVICE Before you do any work yourself, on electrical circuits, equipment or appliances, always turn off the power at the breaker or fuse panel BEFORE you attempt to do any work and always use a test meter to ensure the circuit is, in fact, de-energized. IF YOU ARE NOT REALLY SURE YOU CAN DO THIS JOB SAFELY AND COMPETENTLY PLEASE REFER THIS WORK TO QUALIFIED PROFESSIONALS.
You can reset a circuit breaker but a fuse you must replace.
A bad circuit breaker. Replace it.
No.
You should replace the surge strip if the circuit breaker fails to reset.
Replace it immediatly, the breaker is no longer within code.
A circuit breaker is designed to 'break' in a circuit if a short circuit (or other malfunction) occurs. This prevents overheating (or burn-out) of the circuit wires. In older systems, you would need to find which fuse wire has fused and replace it. In a circuit breaker, once the fault has been found and corrected, the breaker is simply switched back on.
Replace the 30 Amp Breaker with a 15 Amp breaker.
No. The breaker must protect the circuit components such as wiring, outlets and switches that are connected to the breaker. Therefore if you have a 30 amp circuit as dictated by its components you need to protect it with a 30 amp or less breaker.
A circuit breaker is a switching device which can make,brake and carrying (or trip the circuit) that specified over currents for a small interval of time . There is a different types of Circuit Breaker's are there 1.According to their arc quenching media these are divided into 4 types a) Oil circuit breaker b) Air blast circuit breaker c) SF6 circuit breaker d) vacuum circuit breaker 2. According to their services the circuit breaker can be divided as a) Outdoor Circuit Breaker b) Indoor Breaker 3. According to the operating mechanism of circuit breaker they can be divided as a) Spring operated Circuit Breaker b) Pneumatic Circuit Breaker c) Hydrolic Circuit Breaker 4. According to the voltage level of installation these are divided into 3 types a) High Voltage Circuit Breaker b) Medium Voltage Circuit Breaker c) Low Voltage Circuit Breaker.
The breaker will have a black wire connected to it. Turn off the main breaker and then disconnect that black wire from the breaker. The breaker will snap into the main bar. Remove the breaker and install the new one. Reconnect the black wire to the breaker and then install the cover and turn the main breaker back on.
The circuit breaker for the headlights is intergrated with the headlight switch.
Usually it means to blow it, it broke - you need to flick a breaker or replace it as it blew.