Asking this type of question usually means you aren't ready to do this yourself.
If you get any detailed "how to do it" answer here, you might attempt to do something you shouldn't be doing, and that may cost someone a shock, a home fire, or their life.
<><><>
(LIFE SAFETY WARNING! [disclaimer]
Electricity is dangerous!
You can be injured or killed!
Improper installations can cause fire, injury and death!
Should you be doing this yourself?)
This is one of those questions - if you know this little, you shouldn't be doing what you are planning...
No disrespect intended, but this is SO basic that it suggests you have not studied the subject at all ...and you obviously don't have enough experience to do this safely!
Electricity is dangerous!
You can be injured or killed!
Call an electrician!
<><><>
As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.
If you do this work yourself, always turn off the power
at the breaker box/fuse panel BEFORE you attempt to do any work AND
always use an electrician's test meter having metal-tipped probes
(not a simple proximity voltage indicator)
to insure the circuit is, in fact, de-energized.
IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS
WORK SAFELY AND COMPETENTLY
REFER THIS WORK TO QUALIFIED PROFESSIONALS.
To replace breakers in an electrical box it is extremely important the replace the breaker with the same wattage. Do not replace a 100 breaker with a 20 breaker is can cause damage.
1950's
You will need a 220 volt primary isolation transformer with a split, center taped, secondary 220 volt winding.-------------------Answer for USAIf you live in the United States and your 220v circuit is a 2-pole circuit, you replace the 2-pole breaker with 2 individual 110v breakers and **PRESTO** you are now ready to run 2 individual 110v circuits.If you wish to use existing wiring, and you have 3 wires plus ground, you have all you need. These 2 circuits can share the same neutral without any electrical danger.Before you do any work yourselfon circuits, equipment or appliances,ensure the circuit is, in fact, OFF.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.
you have to replace them......they are not self resting.
Yes, but they are easy to replace.
Some Siemens may work but remember you are responsible for any fire or lives lost that may occur from using the wrong breaker. Get Gould breakers and you will then know they are safe. Can't find Gould breakers then replace the entire service panel. That is what I would do.
GE circuit breakers with catalog numbers ranging from THQL1115 through to THQL1150 can be substituted like for like with Cutler-Hammer circuit breakers coded CL115 through to CL150, ITE Siemens circuit breakers coded Q115 through to Q150 and Square D circuit breakers coded HOM115 through to HOM150. These are single pole breakers. GE circuit breakers with catalog codes from THQL2115 through to THQL2150 can be substituted with Cutler-Hammer circuit breakers CL215 through to CL250, Square D circuit breakers HOM215 through to HOM250 and ITE Siemens circuit breakers Q215 through to Q250 of the same amperage and voltage. These are double pole breakers.
you have to remove the fuel pump it is connected to it, it has to be replace as one unit
Yes. However make sure you replace the HO transmission as well. There may also be some rewiring that will need to be done as well. Also, replace the U-joints on the drive line for the upgrade.
The only time 2 beakers are run to one outlet is if the outlet is 240V. The breakers should have handle-ties connected to them to ensure that both breakers trip in the event of an overload. Nope its not 240 either,cause it continues to other outlets the same way.and can plug 110 accesories into them. I have come accross this everywhere. In rooms without a ceiling light, one half of a duplex receptacle is a switched lighting circuit and the other is a always on receptacle.
My mistake. They are single pole 30 amp breakers. Probably should replace with a double pole. Sorry for any incovenience to this forum. d
££££ big money mate, have a shop around your local breakers or e-bay for an engine