Corona Fields arround a transmission line is the high electric field caused by the transmission line causing the surrounding air to ionise and conduct electricity. As this ionisation requires a current to maintain, this causes a loss associated with the corona.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar
More answers
User Avatar

Anonymous

Lvl 1
4y ago

It is very effectively descirbe in the contagion movie. Actually it shows how it spread and danger of it. I saw a video of this movie and real situation compared video. i share it with this .

youtubecom/watch?v=UmUykwjg6ic&t=3s

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is Corona power loss in transmission line?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

What is the amount of power loss on a transmission line that is transmitting 10 MW at 500 kV with 1000 ohms?

Line current = 10MW / 500kV = 20A Assuming the 1000 ohms is the resistance of the entire transmission line, end to end. Power loss = line current ^ 2 * line resistance = 20A ^ 2 * 1000 ohms = 400 KW


What is formula for calculation of line loss?

Line loss equations are complicated by transmission environment and temperature?Transmission env. - Include wire type, bus impedance in switching fields, etc.Temperature - Temperature can change the wire resistance and thus line loss.Electric energy is transported across the countryside with high-voltage lines because the line losses are much smaller than with low-voltage lines.All wires currently used have some resistance (the development of high-temperature superconductors will probably change this some day). Let's call the total resistance of the transmission line leading from a power station to your local substation R. Let's also say the local community demands a power P=IV from that substation. This means the current drawn by the substation is I=P/V and the higher the transmission line voltage, the smaller the current. The line loss is given by Ploss=I²R, or, substituting for I,Ploss = P²R/V²Since P is fixed by community demand, and R is as small as you can make it (using big fat copper cable, for example), line loss decreases strongly with increasing voltage. The reason is simply that you want the smallest amount of current that you can use to deliver the power P. Another important note: the loss fractionPloss/P = PR/V²increases with increasing load P: power transmission is less efficient at times of higher demand. Again, this is because power is proportional to current but line loss is proportional to current squared. Line loss can be quite large over long distances, up to 30% or so. By the way, line loss power goes into heating the transmission line cable which, per meter length, isn't very much heat.


How do you compute energy loss in transmission line?

Energy loss is I^2*R losses. Calculate the transmission line resistance, and multiply by the current squared per unit time (seconds if in watt/seconds, for example).


What is percent of power loss at 415 volts against 11000 volts?

Power = voltage times current, and the power loss is the loss in the line, I^2 * R. At 11,000 volts, the current will be (11,000 / 415 = ) 3.77% of what it is at 415 volts. So the power loss in the line at 11,000 volts will be (3.77% ^2 = ) .14% of what it is at 415 volts.


What type of transformer is needed before the electricity from the Power Station is sent into the National Grid?

From the Generator station, the voltage is sent to a step up transformer. Transmission at higher voltages is used to over come line loss over the miles of transmission.

Related questions

What is corona power loss in transmission line hvdc?

A: Transmission lines while there is ceramic insulators providing separation to the phases will have a corona if the insulators are dirty providing small current leakage ionizing the air around it therefore corona effect.


What is the amount of power loss on a transmission line that is transmitting 10 MW at 500 kV with 1000 ohms?

Line current = 10MW / 500kV = 20A Assuming the 1000 ohms is the resistance of the entire transmission line, end to end. Power loss = line current ^ 2 * line resistance = 20A ^ 2 * 1000 ohms = 400 KW


What is surge impedance in power systems?

Actually surge impedance is present in a transmission line due to the capacitance of transmission line. Now this capacitor attends the reactive power of the transmission line to energise its magnetic flux. now due to the flux the impedance will increase and the power is reactive too. due to the impedance loss is more.


What is the efficiency of a transmission line?

Transmission line efficiency is power at the recieving-end of the line compared to the power at the sending-end of the line and is expressed as a percentage, so this can be formulated. % efficiency = load power (output) / source power (input) x 100 In the line, there are power losses. to calculate this we use the formula: power loss = 3.I2.R where I is current and R is resistance. Now that we have the losses, we know the difference between the input and the output. So, for example, if one had the output value known, then to get the input we just add the loss to the output or if had the input known, just subtract the loss from it to get the output. hope that helps


What frequency corona loss is more?

frequency is directly propotional to corona loss... so higher the freq the corona also high..


What is signal distortion in transmission lines?

there are some distortion in transmission line : copper loss,dielectric loss,skin effect


What is insertion loss in network analysis?

The Insertion Loss of a line is the ratio of the power received at the end of the line to the power transmitted into the line.


What does power loss in electrical transmission mean?

The term, 'power loss', describes the rate of energy losses caused by the load current in the transmission lines


Is reactance major responsible for power loss in power transmission lines?

Reactance certainly causes loss in a transmission system, but I^2R or resistance losses are greater.


What is formula for calculation of line loss?

Line loss equations are complicated by transmission environment and temperature?Transmission env. - Include wire type, bus impedance in switching fields, etc.Temperature - Temperature can change the wire resistance and thus line loss.Electric energy is transported across the countryside with high-voltage lines because the line losses are much smaller than with low-voltage lines.All wires currently used have some resistance (the development of high-temperature superconductors will probably change this some day). Let's call the total resistance of the transmission line leading from a power station to your local substation R. Let's also say the local community demands a power P=IV from that substation. This means the current drawn by the substation is I=P/V and the higher the transmission line voltage, the smaller the current. The line loss is given by Ploss=I²R, or, substituting for I,Ploss = P²R/V²Since P is fixed by community demand, and R is as small as you can make it (using big fat copper cable, for example), line loss decreases strongly with increasing voltage. The reason is simply that you want the smallest amount of current that you can use to deliver the power P. Another important note: the loss fractionPloss/P = PR/V²increases with increasing load P: power transmission is less efficient at times of higher demand. Again, this is because power is proportional to current but line loss is proportional to current squared. Line loss can be quite large over long distances, up to 30% or so. By the way, line loss power goes into heating the transmission line cable which, per meter length, isn't very much heat.


How do you compute energy loss in transmission line?

Energy loss is I^2*R losses. Calculate the transmission line resistance, and multiply by the current squared per unit time (seconds if in watt/seconds, for example).


Now days Why we are not using the wireless elctricity transmission?

Power loss.