220 to 240 V
clark kent
The nominal voltage in the UK is 400/230 V. That is 400 V line-to-line (i.e. line voltage), and 230-V line-to-neutral (i.e. phase voltage). Allowable variation is +10% and -6%.
the inductive load which is generally use in high voltage transmission line known as transformer. the transformer transform the high voltage to low voltage.
The line current increases when more bulbs are switched on in parallel, since more parallel current paths results in lower effective resistance. The line voltage should not change in response to any normal use of electric power in a single house.
Yes. Because... If we connect an alternator to a transmission line of high capacitance the line voltage will increase and caused a line voltage difference, which does not satisfied the condition of parallel operation of same voltage rating. [By Akhtaruzzaman08]
clark kent
The voltage in North America can be as low as 110 and as high as 125 volts. The average is about 115 to 117 volts. <><><>><> House voltage in the US is generally 120v line to neutral and 240v line to line. It is referred to as a "120/240v single phase service." Actual voltage can be as low as 110/220 or as high as 125/250.
No. Line voltage is 120v or some multiple there of. It is the potential that comes in from the grid and is found on the hot conductor in your house wiring. 24 volts is "low voltage" and tends to be used only for switching and lighting. Also, 24 volts is often DC (though not always) while line voltage is invariably AC
Phase to Phase voltageCorrection to the above answer:There is no such thing as a 'phase-to-phase' or 'phase-to-ground' voltage. The correct terms are 'line-to-line' (or 'line voltage') and 'line-to-ground' (or 'phase voltage'). Transmission-line voltages are line-to-line (or 'line') voltages.
There are thousands clearing houses in Bangladesh.
what called to India-Bangladesh border line
A voltage is applied to a signal line. The voltage of the line changes gradually from 0 to +V. The "edge speed" is the rate of change of voltage of the line. A voltage is applied to a signal line. The voltage of the line changes gradually from 0 to +V. The "edge speed" is the rate of change of voltage of the line.
The term, 'unbalanced system' refers to an unbalanced load. Under normal circumstances, an unbalanced load leads to unbalanced line currents. The line voltages are determined by the supply and remain symmetrical, even when the load is unbalanced. As your question refers to a 'line to neutral' voltage (i.e. a phase voltage), you must be referring to a star (wye) connected load, in which case the phase voltage (line to neutral voltage) is 0.577 (the reciprocal of the square-root of 3) times the line voltage (line to line voltage).
Phase, if you are referring to line, as power line from pole.
the voltage between 1 line & phase =120v The voltage between 2 line =240
In a 3 phase system, the voltage measured between any two phase is called line to line voltage.And the voltage measured between line to neutral is called phase to neutral (line to neutral) voltage.AnswerThere is no such thing as a 'phase-to-phase' or a 'phase-to-neutral' voltage. The correct terms are 'line-to-line' and 'line-to-neutral'.The voltage between any two line conductors is called a line voltage.In a three-phase, three-wire, system, the line voltage is numerically equal to the phase voltage.In a three-phase, four-wire, system, the voltage between any line conductor and the neutral conductor is called a phase voltage. The line voltage is 1.732 times larger than the phase voltage.
To match 2 phase line voltage it has to be the same voltage.