Best Answer

The first thing that springs to mind is that the pole faces of the contactor are dirty. If the contactor is in a position where it can get weathered, it would probably be a rust built up. Dis assemble the contactor and emery cloth the pole faces until they are shiny again. A light wiping of oil will increase the time between cleanings. If the sound is more like a chatter then the shading coil on the contactor's pole face could be cracked or broken. This small copper coil is used to induce magnetism into the pole face to hold the contactor closed as the voltage transits through the zero voltage of the sine wave cycle.

User Avatar

Wiki User

12y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What would cause a lighting contactor to hum vigorously?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What type of switch would be used to control a lighting load from one control point?

In this type of situation, where there is more than one lighting circuit, a lighting contactor would be used. These types of contactors can be obtained in four and five pole configurations. Make sure that the contactor is rated for lighting loads and not motor loads. A normal switch, single pole single throw, would be used to switch the contactors on and off. A single switch could then be used to control as many contactors as you need to operate the lighting circuits.If there is just one lighting circuit, the total circuit amperage must be known, then the switch would be sized to the amperage of the circuit.


What is the main function of a contactor?

A contactor is another name for an electrical relay. It is a device that allows a low current (normal) switch to turn on or off high current equipment such as heaters or air-conditioners that would be well beyond its capacity.


How do electro pneumatic contactors work?

A contactor is an electrically controlled switch (relay) used for switching a power circuit. an electro pneumatic contactor is similar to the above except it uses a pneumatic signal to initiate the switching of the electric power circuit. an electro magnetic contactor is a contactor driven by an electric control signal. It us usually just called a contactor.


What relay would you use to switch 400 watts of fluorescent lights?

There are special contactor that are made to switch lighting loads. These relays and not wattage rated but amperage rated. Use the following formula with the voltage that you are going to use to find the size of contactor that you need. I = W/E, Amps = Watts/Volts.


If you have a bad compressor does that mean you need a new contactor?

Not always. But if a compressor goes bad it can take out the contactor. I have replaced compressors before and found the contactor is still ok. In a commercial application Copeland will not honor the warranty if the contactor is not replaced at the same time a new compressor is installed. Not sure about residential but for a $15 contactor I would not gamble with it.


How would you use the word vigorously in a sentence?

An example of a sentence using the word would be... He attacked the meal vigorously and with relish.


How many phases does a 2 pole contactor have?

Yes, as long as the amperage rating is sufficient. Just don`t wire the second pole until the first pole contacts are spent. Then move the wires over and you effectively get twice the life out of it.


How many wires to control a mechanically held contactor?

A contactor is a type of switch. However this switch uses electricity to power an electromagnetic coil to switch on or off power. Hence a contactor needs 2 wires - A live/hot wire and a neutral wire. Generally these are connected across the A1 and A2 terminals of the contactor.


How many paths for current flow are there in a three pole contactor would allow?

3


What would cause the outside unit not to kick on when the blower unit starts?

disconnect beside unit may have blown fuse or tripped breaker,contactor in outside unit may be bad,or no coolant in system


How would you use lighting in a sentence?

The lighting shock her


What would cause the outside part of your air conditioner to stay on after you turn it off?

A stuck compressor contactor. You can turn off the circuit breaker or pull the outdoor disconnect switch to stop it if you have not already done so.