answersLogoWhite

0


Best Answer

A transformer primary of 1200 turns with a secondary of 400 turns is a ratio of 3 to 1.

User Avatar

Wiki User

12y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: A transformer with a primary of 1200 turns and a secondary of 400 turns has what ratio?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

What is mean by 2is to 3 turns ratio Transformer what is primary turns and secondary turns?

with an ideal electrical transformer with an input current of 2 amps and an output current of 1 amp what is the turns ratio of the secondary and primary coils


An isolation transformer has 500 turns on the primary winding how many turns are on the secondary?

An isolation transformer is intended to isolate the ground path in the primary from the secondary while maintaining the same voltage on the secondary. This means a turns ratio of 1 to 1. If there are 500 turns on the primary, then there will be 500 turns on the secondary.


Difference between input and output transformer?

The 'input' side of a transformer is called its 'primary' side, whereas the 'output' side is termed its 'secondary' side. The ratio of its secondary to primary voltage is equal to the ratio of the number of turns in the secondary windings to the number of turns in the primary winding. So if, for example, a transformer's secondary winding has twice as many turns as its primary winding, then the secondary winding will produce twice the voltage applied to the primary winding.


Does a transformer increase amps?

The primary current is determined by the secondary current, not the other way around. For example, a step up transformer will step up the primary voltage in proportion to the turns ratio of the transformer. Any secondary current is then determined by the secondary voltage and the load, NOT by the primary current. The primary current is then determined by the secondary current in proportion to the reciprocal of the turns ratio.


In transformer how can you increase or decrease the voltage?

In a transformer, you increase or decrease the voltage by changing the turns ratio between the primary or secondary windings. Increase the turns on primary, and secondary voltage goes down. Increase the turns on secondary, and secondary voltage goes up. Note that this usually involves choosing a different transformer, as changing the turns ratio is not something that can be easily done in the field. Some transformers have multiple taps on one of the windings which can be used to change turns ratio.

Related questions

How many turns in secondary coil in Transformer?

It depends on the type of transformer.If it is a step up transformer the number of turns in secondary side is higher than primary.Stepdown means it will have fewer number of windings on the secondary side turns when compared with the primary side.An isolation transformer has the same number of windings on the primary as the secondary.The ratio of the windings is proportional to the increase or decrease in the secondary voltage. For example, twice the windings doubles the voltage and 1/2 the windings halves the secondary voltage. The isolation transformer is denoted as 1:1 and has the same voltage on the secondary as the primary.The ratio of secondary turns to primary turns is the same as the ratio of secondary voltage to primary voltage.e.g. if the secondary to primary turns ratio is 1/10, then the secondary voltage will be one tenth of the primary voltage.


What determines the transformer ratio?

Transformer ratio, more correctly turns ratio, is the number of turns in the primary winding divided by the number of turns in the secondary winding.


What is the definition of transformation ratio?

The turns ratio of a transformer is the number of primary turns to secondary turns. This defines how the transformer will change the voltage and current. For N1 primary turns, and N2 secondary turns, N1/N2 will be the turns ratio; the secondary voltage will be:the primary voltage x (N2/N1); The secondary current will be:primary current x (N1/N2)


What is mean by 2is to 3 turns ratio Transformer what is primary turns and secondary turns?

with an ideal electrical transformer with an input current of 2 amps and an output current of 1 amp what is the turns ratio of the secondary and primary coils


How can find the primary turns of the transformer knowing the primary voltage of the transformer?

The ratio of the primary voltage to the secondary voltage is proportional to the ratio of windings. So if the primary voltage is 120 volts and the secondary is 240 volts there are twice as many turns in the secondary.AnswerAs the previous answer says, you can work out the turns ratio of a transformer, but knowing the primary and secondary voltages will not help you determine how many turns are on each winding.


How do you calculate primary current?

If it's a step up or step down transformer and you know the secondary side current, multiply the secondary current by the turns ratio. If you know the power in the secondary winding but not the current, divide the secondary power by the secondary voltage to get the secondary current and then multiply the secondary current by the turns ratio to get the primary current. The turns ratio is the number of turns on the secondary winding divided by the number of turns on the primary winding. For a step up transformer, the turns ratio will be greater then one. If it's a step down transformer, then the turns ratio will be less than one. If you don't know the turns ratio, divide the secondary voltage by the primary voltage to get the turns ratio.


An isolation transformer has 500 turns on the primary winding how many turns are on the secondary?

An isolation transformer is intended to isolate the ground path in the primary from the secondary while maintaining the same voltage on the secondary. This means a turns ratio of 1 to 1. If there are 500 turns on the primary, then there will be 500 turns on the secondary.


How do you calculate current on the primary side of a transformer only knowing the turns ratio and the voltage ratio?

The primary current on a loaded transformer depends on the secondary current, which is determined by the load. So, if you know the secondary load current, then you can use the turns ratio of the transformer to determine the primary current:Ip/Is = Ns/Np


If a transformer has 20 primary windings and 100 secondary windings and the secondary voltage is 25 what is the primary voltage?

Transformer step-up/step-down voltage is turns-ratio, so if a transformer has 20 primary windings and 100 secondary windings (a turns-ratio of 1 to 5) and the secondary voltage is 25, then is the primary voltage is 5.


Does the formula used to calculate the turns ratio uses the phase voltages and phase current?

For a transformer, the turns ratio always applies between its primary and secondary windings. So the turns ratio for a three-phase transformer is the ratio of primary to secondary phase voltages, not between line voltages.


Difference between input and output transformer?

The 'input' side of a transformer is called its 'primary' side, whereas the 'output' side is termed its 'secondary' side. The ratio of its secondary to primary voltage is equal to the ratio of the number of turns in the secondary windings to the number of turns in the primary winding. So if, for example, a transformer's secondary winding has twice as many turns as its primary winding, then the secondary winding will produce twice the voltage applied to the primary winding.


Does a transformer increase amps?

The primary current is determined by the secondary current, not the other way around. For example, a step up transformer will step up the primary voltage in proportion to the turns ratio of the transformer. Any secondary current is then determined by the secondary voltage and the load, NOT by the primary current. The primary current is then determined by the secondary current in proportion to the reciprocal of the turns ratio.