answersLogoWhite

0


Best Answer

No, the electrical insulation rating of a 15 amp duplex receptacle is only rated at 130 volts. The 15 amp 240 volt receptacle is rated at 250 volts. The 240 volt receptacle also has a tandem pin configuration instead of the parallel configuration of the 120 volt device. The different pin configuration is so that a 120 volt electrical device can not be plugged into a 240 voltage receptacle.

User Avatar

Wiki User

8y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Can you put a 120 v receptacle on a 240 v circuit breaker?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

Can you use a 2 pole breaker for a 120 volt single phase circuit?

A single phase circuit uses a 2 pole breaker if the circuit is 120/240 split phase and the load is connected 240. Both legs are hot, so both need to be protected. This is the normal US/Canada configuration.


Can one leg of a 240 volt circuit be capped and the circuit breaker changed to make an existing 240 volt outlet into a 120 volt outlet?

Yes, you can always have heavier wire than code requires.


Can you use two 15 amp single pole breakers in place of a double pole 30 amp breaker?

Yes. An everyday occurrence of this circuitry is in your kitchen counter split receptacles. The top half of the receptacle is a 15 amp circuit and from the same breaker the bottom half of the receptacle is another 15 amp circuit. A two pole single handle breaker is a common trip. If one of the circuits fed from the breaker faults the other connected circuit will shut off also. If you are talking about slot position in a breaker panel, you can remove the two pole breaker and install two single pole breakers.


What does a circuit breaker look like for 110 volt?

Most of the breakers in a panel will be 120 VAC. Double height breakers are 240 VAC. A triple height breaker probably indicates you have 3-phase power in the panel.


How do you calculate amp of circuit breaker to use on a 4800w oven?

Ovens typically run at 240 volts which will be a two pole breaker in your panel. Watts = volts x amps. 4800 / 240 = 20 amps. If by chance you are using 120 volts then double it to 40 amps. All wiring must conform to size of breaker used.

Related questions

How do you add a 240 volt receptacle to 100 amp supply?

The 240 volt receptacle has to have an amperage rating. It is this rating that governs the wire size and breaker size to feed the circuit. The new two pole breaker will be inserted in the 100 amp distribution if space is available and connected to the new wiring that terminates at the new receptacle.


Can a 240 volt receptacle go on a 15 amp circut breaker?

In North America you would need two 15 amp breakers to obtain 240 volts. The wire for a 15 amp circuit would be #14 AWG. So to answer the question, yes a 240 volt receptacle can go on a 15 amp circuit.


How volts comes from a 20amps breaker?

On most residential circuit breaker boxes in North America, each individual breaker represents one 120-volt circuit. Two breakers ganged together represent a 240-volt circuit.


Can you use a 2 pole breaker for a 120 volt single phase circuit?

A single phase circuit uses a 2 pole breaker if the circuit is 120/240 split phase and the load is connected 240. Both legs are hot, so both need to be protected. This is the normal US/Canada configuration.


Can one leg of a 240 volt circuit be capped and the circuit breaker changed to make an existing 240 volt outlet into a 120 volt outlet?

Yes, you can always have heavier wire than code requires.


How can you determine if you have 110 or 220 volts?

Most residential service in USA has both. In the USA 110 to 120 volts is a given and it would be very unusual not to have 220 to 240 volts. It can be easily tested at main panel with a volt meter. Or as an alternative call your power company.


Why do two circuit breakers control the same circuit 120 volts on all devices in circuit?

Circuit breakers are like fuses that you can reset. There is no need for two though because they do the same job as one, which is to open the circuit as soon as the voltage that is being called for by all the devices becomes greater than the 120v you mentioned. <<>> It sounds to me like you are talking about a three wire split receptacle On kitchen counter plugs and sometimes other locations the electrical code requires that split receptacles be installed. This request came about by people trying to plug too many appliances into one 15 amp circuit. The circuit not being able to carry the load and constantly tripping the breaker. On a split receptacle the tie bar is removed on the hot side (brass) of the receptacle but not on the neutral (silver) side. The red wire is connected to the top brass screw, the black wire is connected to the bottom brass screw and the white (neutral) wire is connected to the other side of the receptacle The rating of the breaker in the panel will be, 2 pole 15 amp. What this gives you is 2 separate 120 volt 15 amp circuits on one receptacle If the voltage was measured between the two hot slots on the right side of the receptacle top and bottom you would measure 240 volts. This voltage would only be 240 if the breaker feeding the receptacle was full size 2 pole and not mini breakers.


How can you wire one half of a 20 amp 120 v duplex wall socket to run 240 volts over 2 legs 2 separate 120 v legs?

You can't. I'm not sure exactly what you're trying to do, but the way it is written is not possible. It seems you might want to use half of a duplex receptacle for 120 and half for 240. This would not be code compliant, nor would it make sense. A plug designed for 240v will not even fit into a 120v receptacle. You need a 240 volt receptacle rated for the amperage you will need. Also, an existing 120v receptacle has nothing to do with your 240v receptacle. For a 240 volt receptacle, you'll need to run 2 new 120v lines (in the same cable). The existing 120v circuit cannot be used here, even if you added another 120v circuit, because when a load uses 240v, both 120v circuits supplying the 240v must be controlled by a common disconnect (a 2 pole breaker designed for 240v circuit). My advice would be to show an electrician what you want done. I'm sure they can tell you how to make that happen.


What type of circuit breaker is required for a 240 v branch circuit?

the circuit breaker used will be miniature circuit breaker(MCB) maily used in homes.Answer for USA, Canada and countries running a 60 Hertz supply service.A two pole circuit breaker is used for a load of 240 volts. It is sized, according to the load amps of the device, to protect the wires that supply the load current.


Can you use two 15 amp single pole breakers in place of a double pole 30 amp breaker?

Yes. An everyday occurrence of this circuitry is in your kitchen counter split receptacles. The top half of the receptacle is a 15 amp circuit and from the same breaker the bottom half of the receptacle is another 15 amp circuit. A two pole single handle breaker is a common trip. If one of the circuits fed from the breaker faults the other connected circuit will shut off also. If you are talking about slot position in a breaker panel, you can remove the two pole breaker and install two single pole breakers.


What does a circuit breaker look like for 110 volt?

Most of the breakers in a panel will be 120 VAC. Double height breakers are 240 VAC. A triple height breaker probably indicates you have 3-phase power in the panel.


How is a circuit breaker panel wired?

how to connect cables to switches 240 box