A motor converts electrical energy into mechanical energy, so it can't be used for lights. But a 3-phase generator or alternator can be used to generate power for lighting. A 3-phase generator can light 3 light simultaneously, or it can be used to with a full wave rectifier (as in a car's electrical generator) to light one light, or several lights, or charge a battery
To use a single/one phase motor instead of a three phase motor is possible if you have a three phase power supply as you will only need to tap one of the three phases together with neutral and an earthwire, however to use a three phase motor instead of a single phase will require the provision of three phase power supply.
It must be a three phase supply service to run a three phase motor.
With no three phase power supply you can't use a three phase motor of any kind at all!
use to run motor
Usually with a voltage of 600 volts the motor will be three phase. To use a transformer with that motor you will need a three phase 240 volt service. These days utility companies are moving away from three phase 240 and substituting it with 120/208. The 208 three phase service has the added bonus that 120 volts can be obtained from the star point (grounded neutral).
No, it is not necessary to have three-phase rotor windings for a transmitter and motor in a selsyn motor. Selsyn motors typically use single-phase rotor windings to transfer information or control signals between devices. The synchronization between the transmitter and motor is achieved through the interaction of the stator and rotor windings.
In an emergency and for a short period of time you can single phase a three phase motor but the motor will be loud, have terrible power characteristics and depending upon the use will burn up rather quickly. You should never try to run this in other than a life threatening emergency situation, the motors are not designed for it. Normally you don't. <<>> A three phase motor will not start on single phase. If the motor was started on three phase and loses a phase, it will stay running at a lower percentage of efficiency. Now a days the motor protection will not let a three phase motor run in a single phasing condition. All three phase legs of the motor are monitored and in a single phase condition the other two legs of the motor draw a higher current. This higher current is sensed by the motor's overload heaters in the motor's contactor and take the motor off line by opening the motor contactor. Now to the question, any two legs of a three phase system in electrical terms is known as single phase. As long as the three phase voltage matches the voltage needed in the single phase power diagram it can be connected to operate single phase equipment.
If the motor wire numbers are L1, L2 and L3, it is not a single phase motor. It is a three phase motor. Also for future reference, a 220 volt single phase motor does not use a neutral.
It is possible to use it
A three-phase motor will not start if one or two phases aren't connected. If while running one or two phases "drop out", it will continue to run for awhile, but will eventually burn out, unless connected to a motor saver.
NO however id uyou use thirtyeen you can gt high (y)
Your question is a little like asking, 'How long is a piece of string?'! Do the two motors have the same power rating, or are they different?The rate at which energy is used by any machine is defined by its power rating. If the power ratings of two different machines are the same, then both machines use energy at the same rate. So if a single-phase motor has the same power rating as a three-phase motor, then they will both use exactly the same amount of energy over a given period of time.So, if a single-phase motor has a greater power rating than a three-phase motor, then the single-phase motor will the greater amount of energy in a given period. On the other hand, if a three-phase motor has a greater power rating than a single-phase motor, then the three-phase motor will the greater amount of energy in a given period.