you need the current of motor or the KW/HP rating
The starter is sized by amperage of the motor. The first thing that has to be done is find the the current by using this formula for amperage when the HP is known. I = HP x 746/1.73 x E x %eff x pf. A standard motor's efficiency between 5 to 100 HP is .84 to .91. A standard motor's power factor between 10 to 100 HP is .86 to .92. Amps = 5 x 746 = 3730/1.73 x 208 = 3730/360 x .84 x .84 = 3730/ 254 = 14.68 amps A three phase size 1 magnetic starter is rated for 27 amps and can be used up to 7.5 HP. If the voltage was 460 to 575 a size 0 could be used.
There are 746 watts in 1 HP. Watts = amps x volts. It depends on the voltage rating of the motor. Amps = 746/volts = ? need voltage.
A single phase 10 HP motor will draw aproximately 50 amps. A three phase 10 HP motor will draw aproximately 28 amps.
A direct on line starter, often abbreviated DOL starter, is a widely-used starting method of electric motors. The term is used in electrical engineering and associated with electric motors. There are many types of motor starters, the simplest of which is the DOL starter. A motor starter is an electrical/electronic circuit composed of electro-mechanical and electronic devices which are employed to start and stop an electric motor. Regardless of the motor type (AC or DC), the types of starters differ depending on the method of starting the motor. A DOL starter connects the motor terminals directly to the power supply. Hence, the motor is subjected to the full voltage of the power supply. Consequently, high starting current flows through the motor. This type of starting is suitable for small motors below 5 hp (3.75 kW). Reduced-voltage starters are employed with motors above 5 hp. Although DOL motor starters are available for motors less than 150 kW on 400 V and for motors less than 1 MW on 6.6 kV. Supply reliability and reserve power generation dictates the use of reduced voltage or not. A very well-known motor starter is the DOL Starter of a 3-Phase Squirrel-Cage Motor. This starter is sometimes used to start water pumps, compressors, fans and conveyor belts. With a 400V, 50 Hz, 3-phase supply, the power circuit connects the motor to 400V. Consequently, the starting current may reach 3-8 times the normal current. The control circuit is typically run at 24V with the aid of a 400V/24V transformer
Which starter is best for 7.5 hp 3phase motor?Read more: Which_starter_is_best_for_7.5_hp_3phase_motor
No.
10 hp and above motor power rating....
1 HP electric motor = 1.5 HP hydraulic motor so for a 3 HP electric motor you would need a 4.5 HP hydraulic motor. Also for your information a 1 HP hydraulic motor = 1 2/3 HP gasoline engine.
It depends on which engine is in the machine. I have one with a replacement 18 HP Onan engine and the starter is down low on the left side of the motor. Follow the wires from your battery and it will lead you there as well.
Before this question can be answered, you need to specify whether it had the 250 hp Quad Four motor, or the 255 hp V6 motor.
i have 200 hp motor what i need cable size in 100 feet distance
To determine this you will have to measure the amperage the starter draws when you crank the engine. This amperage times the voltage (12 volts) will give you the wattage. There are 746 watts to 1 HP.
do you need a boat licence for a 5hp outboard
you need the current of motor or the KW/HP rating
Need the HP to answer. If 6 HP, the mixture is 100:1