In North America the calculations for people in the trade comes from the CEC or NEC electrical code book. The table states what the rating or setting of over current devices for the protection of motor branch circuits should be. If protected by time delay fuses the protection will be 175% of the motors full load amperage. Non time delay fuses the protection will be 300 % of the motors full load amps. The maximum setting time-limit type circuit breaker is to be set at 250% of the motors full load amperage.

User Avatar

Wiki User

10y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How calculate motor starting current using DOL starter?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

How do you calculate voltage drop for starting motor current and how to get the starting pf?

How do you calculate voltage drop for starting motor current


Why using on motor star delta starter?

because at the starting the induction motor drawn a heavy current thats why we use starter to increase the starting resistance of the induction motor!


Why you use DOL starter in starting of motor?

because of starting current of induction motor is very high and it damages the insulation of motor


What are components of a DC motor starter that can be affected by a high starting current if it is not limited?

armature


What is a disadvantages DOL or direct online starter?

it can not be use for heavy duty motors as well as it requires a high starting current.


What is the formula to calculate the overload setting for a star delta starter?

Full load current ofthe motor x 0.58


When starting a motor car a current of 80 Amps is drawn from the 12 volt car battery. How much Power is dissipated in the starter motor?

12ooo


What is a three point starter?

A three point starter is a device that is meant to help start a DC motor. A three point starter will start device without much starting current.


Which motor is used for starting engine?

Er... a Starter Motor?


What supply is needed to run a 22kw 3ph motor?

question is incomplete, I think you ask how much current consumed by this motor. for starting this motor we need a star/delta starter and a three phase supply.


Is four point starter is applicable to compound motor?

Yes! · To accelerate the motor to the rated speed · To limit the starting current in the armature to a safe value · To disconnect the motor in case of a supply failure or overload


What is the advantage of a Star Delta Motor Starter?

The inrush current to the starting motor is lower due to the the motor coils being in series across the line creating a higher impeadence. When the starter connects to delta connection the motor is already turning and it does not have to go through the locked rotor phase. This system is being phased out now with the use of electronic soft starts and by-pass contactors.To start a motor direct on line (DOL) in delta requires approximately 6 to 8 times the full load current of the motor and delivers full torque. Delta places 415v across each of the windings on the motor. A Star-Delta starter starts the motor in Star which places 240v across each winding on the motor. This results in a lower starting current and also a lower starting torque.