Want this question answered?
You measure the capacitance of a capacitor in an active circuit by observing the voltage across it and the current through it. That gives you, by Ohm's law, the impedance of the capacitor. Plug that in the the equation for capacitive reactance, and you get capacitance. Note: There is no such thing as a three phase capacitor. A capacitor is a two terminal device that resists a change in voltage inversely proportional to its capacitance. You connect one capacitor to one phase. If you have a "three phase capacitor", then you are talking about three capacitors. Deal with each one separately.
A run capacitor and a starter capacitor are not the same thing. A run capacitor is energized the entire time the motor is running, and a start capacitor is not. A run capacitor is one that changes the current on the windings of a single phase AC induction motor to create a rotating magnetic field to energize a second-phase winding. A start capacitor increases starting torque, allowing a motor to be turned on rapidly. It stays in the circuit only long enough to bring the motor to 3/4 of full speed. Some motors then continue to run with a run capacitor.
If a capacitor is directly connected across a motor then the capacitance of the capacitor will be calculated as under.Q = 0.9 * Sqrt (3) * V * I0.Here "V" = Supply voltage & I0 = No Load Current of Motor.AnswerThere is no need to connect capacitors across a three-phase motor.
No, The windings in single phase and 3 phase are different. A single phase motor may use a capacitor "start" circuit to create a phase shift between windings and determine the direction it will spin. A 3 phase motor has the windings configured to create a directional rotating field which determines the rotation. The capacitor in a single phase motor is not used to convert it to 3 phase or vice-versa.AnswerIf you have access to a three-phase supply, then you alsohave access to a single-phase supply by connecting your motor to any two line conductors, or between any one line conductor and the neutral. But you MUST ensure that the motor's rated voltage matches one or other of the single-phase voltages available -that depends on what country you live in, because three-phase voltages vary from country to country. And, obviously, if you don't know what you are doing you must consult a qualified electrician.
with 3 phase the rotating field is already set up when power is supplied with single phase you use a capacitor and a second winding to set up the rotating field
how to connect power capacitor with 3 phase motor
Just use any two of the three terminals that are available, this will give you a single phase capacitor.
You measure the capacitance of a capacitor in an active circuit by observing the voltage across it and the current through it. That gives you, by Ohm's law, the impedance of the capacitor. Plug that in the the equation for capacitive reactance, and you get capacitance. Note: There is no such thing as a three phase capacitor. A capacitor is a two terminal device that resists a change in voltage inversely proportional to its capacitance. You connect one capacitor to one phase. If you have a "three phase capacitor", then you are talking about three capacitors. Deal with each one separately.
Using a properly rated voltmeter and following all safety precautions, check from phase to phase on each phase on the secondary side. phase 1-2 then 2-3 then 1-3 and they should all be within a few volts of each other.
A run capacitor and a starter capacitor are not the same thing. A run capacitor is energized the entire time the motor is running, and a start capacitor is not. A run capacitor is one that changes the current on the windings of a single phase AC induction motor to create a rotating magnetic field to energize a second-phase winding. A start capacitor increases starting torque, allowing a motor to be turned on rapidly. It stays in the circuit only long enough to bring the motor to 3/4 of full speed. Some motors then continue to run with a run capacitor.
usually they say its possible 2 convert a 2phase supply to 3 phase.if its so then how?
The single phase induction motors are made self starting by providing an additional flux by some additional means. Now depending upon these additional means the single phase induction motors are classified as: 1.Split phase induction motor. 2.Capacitor start inductor motor. 3.Capacitor start capacitor run induction motor. 4. Shaded pole induction motor.
Pressure is equal to voltage and is the potential deference between the capacitor two terminals
A single phase motor does not actually require a capacitor. This device is only needed when a split phase motor is utilised. A split phase motor needs a device to regulate the power factor associated with the split phase.
use a rotor phaser or simply connect a 3 phase motor and check dirrection
Check on this link for answer : http://www.hypergurl.com/blog/databases/two-phase-protocol.html
If a capacitor is directly connected across a motor then the capacitance of the capacitor will be calculated as under.Q = 0.9 * Sqrt (3) * V * I0.Here "V" = Supply voltage & I0 = No Load Current of Motor.AnswerThere is no need to connect capacitors across a three-phase motor.