The load contactor is what the motor load is usually connected to. The auxiliary contacts are usually used in the stop start remote wiring to seal the mag in. Auxiliary contacts are also used to transmit the status of the contactor to a PLC.
A blowout coil connected in series with contactor's auxiliary contacts that shunt around the main contactor contacts. The coil is out of the circuit when the main contactor contacts are closed and in the circuit when the main contactor contacts are open.
It provides stability in case of problems with disconnectors auxiliary contacts (stuck contacts or wiring problems). Ir relies on the feeder currents in the busbar. Disconnectors positions are not required. There is no selectivity using check zone. It's usefully because it prevents external faults to be considered as a busbar fault.
to protect or to calculate the operating conditions of an electrical system and to camand circuitbreaker to trip in any fault detection.relay is the one which detects the abnormal condition of the circuit and signals the circuit breaker to trip(open).....
It is a stop valve placed on an auxiliary piece of equipment. Or it could be placed at the steam main to feed an auxiliary steam system (heating, auxiliary pumping. etc.). It is not the Main steam stop for the boiler or the prime mover (engine, turbine, process), it is for a secondary service.
Normally open contacts close and normally closed contacts open.
call an electrician
The load contactor is what the motor load is usually connected to. The auxiliary contacts are usually used in the stop start remote wiring to seal the mag in. Auxiliary contacts are also used to transmit the status of the contactor to a PLC.
There are three main parts of a magnetic contactor. These include the power contacts, contact springs, and the auxiliary contacts.
The relay is used to "interlock" a circuit. It consists of a coil and a number of auxiliary "normally open" or "normally closed" contacts. A limiting condition is wired through the coil contacts and resulting conditions are wired through the auxiliary contacts. When the limiting condition is met, the coil will pull in and change the state of the auxiliary contacts. For example, if you want a lamp (lamp 1) to turn off when a second lamp (lamp 2) is turned on, lamp 1 would be wired through a "normally closed" set of contacts and lamp 2 would be wired through the coil contacts. When lamp 2 is turned on, the coil will pull in and open the "normally closed" contact for lamp 1, turning it off.
Feedback to a control circuit that the motor starter has closed or opened its contacts as commanded.
One way is to use the auxiliary contacts on the motor contactor to close a separate source supply to drive an auxiliary relay.
A blowout coil connected in series with contactor's auxiliary contacts that shunt around the main contactor contacts. The coil is out of the circuit when the main contactor contacts are closed and in the circuit when the main contactor contacts are open.
Contactors have both power and auxiliary contacts. We use the auxiliary contact to control magnetic system of contactor. When a heater , relay or a key warn the contactor it is energized and by the typical magnetic interaction it opens its closed power contacts.
Auxiliary relay is a relay which will repeat the operations of protective relay such as tripping, time lag, breaking of trip circuit current, giving alarms and showing flags etc..Protective relay contacts are delicate and light weight hence it will not capable of carrying a large amount of current for a long period.protective relays do not have enough contacts to perform all the operations of protective scheme.Therefore auxiliary relays, auxiliary switches and repeat contacts are used to assist protective relays.
De-energize it and note the position of the contacts.
The auxiliary contact is to be utilized for interlocking of another relay or contactor or indication signal from another equipment.