Q: How do you calculate full load in single phase circuit?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

What is the difference between a half bridge and a full bridge inverter?

A half bridge inverter is an electronic circuit that uses different phases to do what it needs to do. A full bridge inverter is a single phase device so a half bridge is more complicated than a full bridge.


How does a dol starter work?

A Direct-On-Line (DOL) starter is an electronic 3-phase motor-control system which offers soft starts in DELTA configuration. DOL starters are now replacing the use of manual or semi-automatic "star-delta" starters.In this way of starting a 3-phase motor, full line voltages are applied to the motor through relays and contactors. The DOL is nowadays the most common type of 3-phase motor starter used.It has a "closing circuit" and an "opening circuit". The closing circuit is for applying the service lines to the motor and the opening - or "tripping" - circuit protects the motor by cutting-off (or "tripping") power to the motor from the service lines if there is any overload condition, a single phasing fault, etc.For more information please see the answers to the Related Questions shown below.


What is run capacitor in single phase motor starter with three wire?

A run capacitor and a starter capacitor are not the same thing. A run capacitor is energized the entire time the motor is running, and a start capacitor is not. A run capacitor is one that changes the current on the windings of a single phase AC induction motor to create a rotating magnetic field to energize a second-phase winding. A start capacitor increases starting torque, allowing a motor to be turned on rapidly. It stays in the circuit only long enough to bring the motor to 3/4 of full speed. Some motors then continue to run with a run capacitor.


What are the advantages of 3 phase generators as compared to single phase generators?

For those who need a three-phase supply, they are essential. If a single-phase supply is needed, a three-phase generator is uneconomic. Three-phase is used for loads of more than about 15-20 kVA.


What is a single phase supply?

is the measured voltage,generated between a line voltage and the starting point of a three phase transformer, which is the neutral point. Answer: it is an ac circuit in which the supply has a live and neutral wire, usually at one of the standard voltages 110/120v or 220/240 v. A three-phase circuit is a combination of three single-phase circuits with the phases of the voltages 120 degrees apart so that they peak in a regular sequence.

Related questions

What is a three phase full wave converter?

simplified circuit for three phase cycloconveretr?


Why three-phase rectifier is preferred upon single-phase rectifier?

The choice of single or three phase depends on the available supply. But a three-phase full wave rectifier provides 6 pulses of DC per cycle, while a single-phase full-wave rectifier provides only two. That makes the output DC easier to smooth.


What is the difference between a half bridge and a full bridge inverter?

A half bridge inverter is an electronic circuit that uses different phases to do what it needs to do. A full bridge inverter is a single phase device so a half bridge is more complicated than a full bridge.


What circuit breaker rating do you need for a 3 phase electric motor?

The circuit breaker is sized to the full load amps of the motor times 250%.


What will be the full load current of single phase 5Kva ups?

Assuming single phase voltage 220 Volts AC, the maximum current would be approximately 25 amps.


Can you operate single phase motor from drive?

yes it is possible if you provide full details


What is is the formula for calculating the full load current of 23KVA generator?

to calculate the motor full load current one should know motor power factor, supply voltage and phase of supply. Assuming your motor is with 0.85 pf and 3 phase, 415V source then P = (Sqrt3)*V*I*pf 18500 = 1.732*415*0.85*I hence I = 30.2A


What is the electrical rating for a Quincy QT-54-5-60VE air compressor?

Assuming your power supply is 230 volts, single phase: Full load amp draw = 21, circuit breaker = 50, minimum wire size = 10.


How many diodes in full wave rectifier?

Depends on the number of phases.single phase uses 4 diodesthree phase uses 6 diodes


How do you determine maximum HP possible on a single phase?

1. What voltage is the circuit? 2. What is the overcurrent device (breaker/fuse) rating? 3. What is the branch circuit wire size? The wire must be sized to carry the full breaker rated ampacity The branch circuit should not be loaded to greater than 80% of the breaker's rating. Volts X 80% of breaker amps = watts available. Single phase motors rule of thumb is 1100-1400 watts per HP. The precise maximum HP will depend on the current draw of the exact motor you choose, motor ratings do vary. On a 120v, 20a circuit for instance, 2HP is about it. On a 240v, 70a circuit, you can get up to a 14HP motor or so. Theoretically, with enough amps and volts, you could put a million HP motor on single phase, so it's really a matter of what motors are available for your particular voltage as well as how many amps you have available.


What is full load current rating for 1000kva xmer?

It depends on (1) its voltage rating, and (2) whether it is single phase or three phase. And the symbol for kilovolt ampere is kV.A -not 'kva'.