Q: What will be the full load current of single phase 5Kva ups?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

How much current will 5 kva ups draws while charging?

- For a single phase supply @ 220 voltscurrent drawn by 5kva UPS = 22.7 amperes (at full load.)


What is full load current rating for 1000kva xmer?

It depends on (1) its voltage rating, and (2) whether it is single phase or three phase. And the symbol for kilovolt ampere is kV.A -not 'kva'.


What is the full load current of a 50 hp three phase ac motor operating at 230 v?

Assuming you can get a three-phase 230 v supply, which has 133 v between neutral and each live, the full-load current assuming a 30% increase for power-factor and efficiency considerations would be 120 amps. In Europe the standard three-phase supply is 400 v. In the US three-phase supplies are normally 208 v or 480 v and an alternative option is a 240/480 v split-phase (single-phase) supply.


Why set an overload relay to full load current divide by root three in a star delta starter?

In a Wye/star system the overloads look at the phase to neutral/ground current; not phase to phase current. Which is always calculated as root three or 1.73205.............etc. Therefore the overloads have to be set to the phase to neutral/ground current.


How do you calculate the no-load current of a three phase induction motor?

All transformers, single phase or three phase have a "no-load current" rating. That is simply the nameplate rating of the Xformer in VA, (volt-amps) or KVA (1000Volt-amps) for larger Xformers. Simply divide the nameplate rating in VA or KVA by the supply voltage and you'll get the Xformers potential maximum output in ampheres.

Related questions

How much current will 5 kva ups draws while charging?

- For a single phase supply @ 220 voltscurrent drawn by 5kva UPS = 22.7 amperes (at full load.)


What is full load current rating for 1000kva xmer?

It depends on (1) its voltage rating, and (2) whether it is single phase or three phase. And the symbol for kilovolt ampere is kV.A -not 'kva'.


Why three-phase rectifier is preferred upon single-phase rectifier?

The choice of single or three phase depends on the available supply. But a three-phase full wave rectifier provides 6 pulses of DC per cycle, while a single-phase full-wave rectifier provides only two. That makes the output DC easier to smooth.


How many amps per phase would a machine rated at 460 amps over three phases take?

It depends on the internal circuit of the machine. If it is star operated its full load current will be same as rated current. If it is Delta operated its full load per phase current will be as given below : Phase current = Line Current / 1.732


What is the full load current of a 50 hp three phase ac motor operating at 230 v?

Assuming you can get a three-phase 230 v supply, which has 133 v between neutral and each live, the full-load current assuming a 30% increase for power-factor and efficiency considerations would be 120 amps. In Europe the standard three-phase supply is 400 v. In the US three-phase supplies are normally 208 v or 480 v and an alternative option is a 240/480 v split-phase (single-phase) supply.


How many 16 Amps per phase welding outlet can you install to a 30 KvA rating transformer?

..the questions does not say wether the 30kVA transformer is 3 phase transformer or single phase transformer..but it is implying that a single phase welding load at 16A per phase is to be connect to it, it is assumed then that the transformer is 3 phase transformer..we assume load is rated 240V.. ..though not much details is given about the transformer voltage specs. but if is rated 3 phase 415/240V, the approx full load current per phase is given by 30KVAx1.3912=41.736A.. ..but if the transformer was rated single phase 240V say, the approx full load current FLC=30000/240V gives 125ampers.. ..if you further devide the FLC by the intended load current.. ..Recommended no of welders per for a 3 phase 415V transformer and assuming single welding sets =41.736/16=2.6..so you can connect max two welding sets to this transformer per phase,..max 6 weld sets can connect at an approx load factor of 76%.. ..for the single phase transformer, FLC/16=125/16, gives 7.8 but is also recommended not to connect more than 6 welding sets to such transformer for the same reasons..


How do you calculate the no-load current of a three phase induction motor?

All transformers, single phase or three phase have a "no-load current" rating. That is simply the nameplate rating of the Xformer in VA, (volt-amps) or KVA (1000Volt-amps) for larger Xformers. Simply divide the nameplate rating in VA or KVA by the supply voltage and you'll get the Xformers potential maximum output in ampheres.


Why set an overload relay to full load current divide by root three in a star delta starter?

In a Wye/star system the overloads look at the phase to neutral/ground current; not phase to phase current. Which is always calculated as root three or 1.73205.............etc. Therefore the overloads have to be set to the phase to neutral/ground current.


What is a full load current in single phase transformer?

It is the rated maximum current that can be taken from the transformer. This is equal to the VA rating divided by the output voltage. So a 6 kVA 240 v transformer would have a maximum current rating of 6000/240 or 25 amps.


What is is the formula for calculating the full load current of 23KVA generator?

to calculate the motor full load current one should know motor power factor, supply voltage and phase of supply. Assuming your motor is with 0.85 pf and 3 phase, 415V source then P = (Sqrt3)*V*I*pf 18500 = 1.732*415*0.85*I hence I = 30.2A


Can you operate single phase motor from drive?

yes it is possible if you provide full details


How many current sensing devices are required by the National Electrical Code to protect a single-phase motor operated on 240 volts?

For a single phase fractional horsepower motor, only one over current device is needed in the motor feeder. This protection can come in the form of a switch which has the overload heater incorporated into it. These switches come in single and double pole configurations. Select the heater for the motors full load current that is taken from the motors nameplate. Search the web for "fractional motor starter switch".