Best Answer

Flange Face Surface FinishThe American National Standards Institute (ANSI) code for flanges and flanged fittings (ANSI B16.5) requires that the flange face has a specific roughness to ensure that this surface be compatible with the gasket and provide a high quality seal. A serrated finish, either concentric or spiral, is required with 30 to 55 grooves per inch and a resultant roughness between 125 and 500 microinches.

This allows for various grades of surface finish to be made available by flange manufactures for the gasket contact surface of metal flanges. These grades are often referred to by name e.g. stock finish. The exact definition of each grade may differ between manufacturers, but can be generalised as follows;

Stock Finish

The gasket contact surface is typically formed by a continuous (sometimes called phonographic) spiral groove generated by a 1.6mm radius round-nosed tool at a feed rate of 0.8mm per revolution with a depth of 0.15mm. This will result in a roughness between Ra 3.2 and 12.5 micrometers (125 - 500 microinch).

Smooth Finish

No definite tool marking should be apparent to the naked eye. This is typically achieved by having the gasket contact surface formed by a continuous (sometimes called phonographic) spiral groove generated by a 0.8mm radius round-nosed tool at a feed rate of 0.3mm per revolution with a depth of 0.05mm. This will result in a roughness between Ra 3.2 and 6.3 micrometers (125 - 250 microinch).

Hydrogen Service Finish

The finish for flanges in hydrogen service is very smooth, typically between Ra 2 and 3.2 micrometers (79 - 125 microinch).

Cold Water Finish

The flange face appears as mirror like. This flange finish is usually expected to be used with metal to metal contact, i.e. without a gasket. It is seldom used in the oil, petrochem and related industries.

Measuring Surface Roughness

Flange finish is generally measured by visual and tactile means. Comparing the feel of the machined face with that of a surface finish comparator gauge, occasionally referred to as a Rupert gauge, is considered adequate.

There are two common methods of expressing roughness. They are the Arithmetic Average Roughness Height (AARH) and the Root Mean Square (RMS) Average.

Arithmetic Average Roughness Height- Calculation of the Arithmetic Average Roughness Height involves measuring the distance of the peaks and valleys and performing an arithmetic average of the measurements.

Root Mean Square Average - Calculation of the Root Mean Square Average involves measuring the distance of peaks and valleys, adding the square of these measurements and calculating the square root of the total.

The RMS value is approximately 11% higher than the AARH value.

User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you check AARH value of flange?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is AARH in flange finish?

Acronym: AARH Definition: Arithmetic Average Roughness Height


What is aarh in valve finish?

Arithmetic Average Roughness Height. It's unit is in microns.


Could an unleveled toilet flange be the cause for a toilet leaking water from the tank?

An "unlevel" toilet flange might be a little difficult for a wax ring to seal, but could not in any way be responsible for a tank leak. If the tank is leaking between the tank and bowl, remove the tank, check the tank itself for a crack or defect, then check the flange gasket and tank bolts and gaskets. How do you know your flange is unlevel?


What is SOFF flange?

Slip-On Flat Face Flange. It means the face of the flange, the surface the physically touches the next flange is flat as opposed to raised (SORF Flange)


What is a swivel flange?

it is a flange that's it


Is companion flange same as threaded flange?

No


How do you fit WNRF flange onto an RTJ flange?

Not. There's no way to connect a WNF to an RTJ flange.


What is a RFFE flange?

Raised face flange end


How do you get the center to center distance of a flange?

If it's wide flange, it's from center of web to web distance. Other structural members, it's center of flange to center of flange.


What is WNRF flange?

Weld Neck Raised Face flange


Why does a drain flange have holes in it?

To allow floor flange bolts to have a place to fit and to anchor the flange to the cement /wood decking


What is a counter flange and how is it different from a normal flange?

The term"counter flange" is used in Europe to refer to a mating flange to make up a flange pair. For example a "counter flange" attached to a pipe must have the same bolt circle diameter, number of bolts, and size of bolts and pressure rating at the equipment nozzle flange provided by an equipment manufacturer.