Best Answer

backflow devices are tested with special test equipment,by certified backflow testors. they are tested for leaky check valves, shut-off valves,differential relief valves and other items such as broken springs. The local city or county water dept. can supply you with certified testors,as well as your phone directory. hope this was helpful.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you check a leaking backflow preventer?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the critical level of a backflow preventer?

the critical level of a backflow preventer is the point at which the outgoing pressure exceeds the incoming pressure


Examples of one way valve?

a backflow preventer valve


What is the difference between Dual check valve and double check valve?

A dual check valve is similar to a double check valve in that it is a mechanical backflow preventer consisting of two independently acting, spring-loaded check valve.


Do you need a backflow preventer with a well pressure tank?

Yes, it is recommended that backflow preventers be used. Some areas may also have laws ensuring their placement on systems.


What is the only way to prevent back flow?

In plumbing, by using a device known as a backflow preventer. It only permits water to move in one direction.


What is a leaky valve that allows backflow of blood?

An incompetent valve allows backflow of blood.


Why do some hot water heaters need thermal expansion tanks and others do not?

I believe that the larger the hot water tank, the greater is the need for an expansion tank. Water expands as it is heated. This is why all hydronic heating systems require an expansion tank. A water heater would need expansion tank when a backflow preventer or check valve is installed in domestic cold water line directly after water meter. Some areas require backflow prevention, but not all. Have to check with local plumbing authority about that.


Where is the water valve to a sprinkler system?

Usually in back, but it may not be a valve on the machine itself. Look for a faucet with a hose running to the machine. If you are referring to the internal valve that turns the water on and off when the machine is cycling, that varies with the make and model of the machine.


What is the cause of sewer backup when all vents and drains and sewer lines are clear?

You may not have a backflow preventer in the main line. This prevents anything coming back from the main line. It may be coming from your neighbors above you on the line.


Is it necessary to have both an expansion tank and a pressure relief valve on a hot water heater?

You must have a pressure relief valve. I believe it is code nationally. I don't think you can buy a hot water tank w/o one. Expansion tank needed also if water meter has backflow preventer, check with local water authority if it does.


Cross reference wix 51068 oil filter to a fram oil filter?

For the MGB, Fram PH43 or WIX Part #51068 or K & N HP-1002, however nerds warn the Fram has no backflow preventer. Interchangeable, not equivalent


What is a barometric loop?

An baromtric loop as regards to plumbing is an 1 way backflow preventer,meaning it prevents backflow from the standpoint of an backsiphonage or an vacuum condition.It is a piping arrangement that consist of an vertical pipe of at least 33.7 feet if I remember correctly where in a perfect vaccum it cant siphon the contents on the supply side past the top of the loop due to the physics of it being impossible to create an perfect vacuum