A male and female thread connection if metal pipe. If poly pipe a welded fusion connection.
poly venal chloride
20
You can put up to a 2 inch pipe into a 4 inch. If you are putting 4 inch to 4 inch, either take out a section of the cast and put the PVC in or cut out a section and connect the PVC to the cast with rubber sleeves meant for this. You can use a saddle clamp for the 2 inch. It is a half round piece of PVC with a 2 inch connection in it. It is held on with two U bolts that go around the cast pipe. Put it where you need it and mark the 2 inch hole on the cast. Drill a series of 1/8 inch holes around this circle. when you get them all drilled, you can break out the plug. Try to keep it from falling into the cast pipe. Put the saddle clamp on and connect the PVC pipe as needed. Seal the saddle clamp to the cast pipe with plumbers putty.
depends on the pipe like if its copper its rated at 300 psi 200 degree F pvc is rated at 200 psi schedule 40 if its black poly it would be 200 psi most all pipes have it on the side of the pipe ,pressure and degrees.
Poly Propylene Random pipe
Termites can and do attack (eat) poly pipe used in pools. Before a homeowner uses poly pipe, it is suggested that they contact the poly pipe manufacturer since studies and the factory specs clearly establish it. I have seen termites repeatedly damage self installed poly pipe on an in ground pool. If poly pipe is used, it is absolutely mandatory that the surrounding soil be be treated for termites.
Coated Copper Pipe that is approved for underground only.
No, you cannot. The plastic pipe will crack creating a damaged and burst pipe. Only metallic type pipes are to be used when using such a clamp.
The purpose if a pipe clamp is to hold it in place. Pipe clamps are typically fastened onto something that is stationary to fulfill its purpose. An example would be a wall for pipe associated with guttering.
hardened poly vinyl chloride
If it is a pipe that is not easily cut out and replaced, you can use a pipe clamp. Wrap the clamp around the pipe and tighten the two bolts to compress it around the pipe. If it is a drain pipe as you say, there is very little pressure on t he line, so the clamp should work fine.
The scientific name for PVC pipe is polyvinyl chloride.
You can replace an exhaust clamp with a new one.
Depends....clamp or weld.
Cast iron drainage pipe with neoprene gaskets and clamp. See plumbing.1800anytyme.com/plumbing-glossary.php
A male and female thread connection if metal pipe. If poly pipe a welded fusion connection.