You can determine if an armature is bad by checking for signs of physical damage, such as burns, cracks, or shorts in the winding. Additionally, using a multimeter to measure the resistance can help identify open or shorted coils. If the armature produces unusual noises or excessive heat during operation, it may also indicate a problem. Testing under load conditions can further confirm its performance and reliability.
bad connection
It does have armature resistance.
Armature reaction is the effect of armature flux on the flux generated by the fied windings.Cross magnetisation and Demagnetising are its consequences.
this is wer the armature conductors ar being mounted,therefor it helps the flexibility of armature conductors.
Difference between field controlled and armature controlled is that field control is open loop and armature current is closed loop.
bad connection
bad armature bushings
armature reactant means loss in armature associated with inductive properties of the coil, while armature reaction include losses due to magnetizing component of current flowing through armature.
Yes, sounds like a loose connection internaly or the Brushes are on there last legs, have it repaired or replaced before it costs you a tow job. Bad brushes will pitt the armature if you plan to have it repaired do it now and hopfully it won't cost you an armature.
In DC series motor, field and armature are in series. so we use only two points. They are line and armature. therefore we use two point starter.
It does have armature resistance.
The main difference between a 12-volt armature and a 24-volt armature is the voltage rating at which they operate. A 12-volt armature is designed to run on a 12-volt electrical system, while a 24-volt armature is designed for a 24-volt electrical system. This difference determines the power and speed capabilities of the armature when used in electrical devices.
Armature reaction is the interaction between the magnetic flux produced by armature current and that of the main magnetic field in an electric motor or generator.
Typically, the first indication is the starter solenoid clicks but the starter does not spin. This indicates a dead or weak spot on the armature where the brushes must make good contact. Usually, trying to start the engine a couple more times will result in success. This could go on for a very long time before you actually need to replace the starter (I know). But, it is better to replace as soon as this happens a couple times, because you just don't know when it won't resuscitate itself someday. The other indication that a starter is going bad (or is bad) is if it pulls the battery way down when you try to start. This indicates a shorting of the armature to ground during rotation. Replace immediately.
Armature reaction is the effect of armature flux on the flux generated by the fied windings.Cross magnetisation and Demagnetising are its consequences.
this is wer the armature conductors ar being mounted,therefor it helps the flexibility of armature conductors.
armature reaction means when load is added to the armature then current is passed through armature conductors then in armature creates flux. It is demagnetize and cross magnetize the main field flux. in other ward it is effect of armature field on main field.