Q: How do you read discharge superheat?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Why would you have low discharge superheat?

low dish sper heat


What happening when you are overcharging an air conditioning with freon?

discharge pressure is high, suction pressure is high superheat is low and subcooling is high.


What is suction and discharge superheat?

Suction superheat is the heat added to the refrigerant above that required to change its state from liquid to vapour (as happens in the evaporator). This heat is added both in the evaporator, in the suction line and (where applicable) in the suction accumulator.Discharge superheat is suction superheat plus heat of compression, and must be removed in the condenser before condensation, the change of state from vapour to liquid, can occur.The HVAC Veteran


When was Superheat created?

Superheat was created on 2000-01-25.


Do you add freon on a low superheat or high superheat?

add


Can an undercharge cause superheat?

Undercharge can cause HIGH superheat. Overcharge can cause LOW superheat. You need some superheat when charged correctly. How much is needed is depending on outdoor air temperature and indoor wet-bulb temperature.


I received my discharge on 04142008 and filed my taxes on 04152008 will i get the refund?

It is probably addressed in the discharge agreement...read it.


Excess superheat in a capillary tube system means that there is?

excess superheat in a capillary tube systems means that there is ______ charge


Why is the degree of superheat of refrigerant does not exceed 5 degree centigrade?

We require to superheat the refrigerant to ensure that no liquid enters in the compressor.So in most of the cases degree of superheat is kept 2 to 3 deg c


What are the right temperature on superheat and sub cool?

The right temperature to superheat and sub cool a substance varies greatly. Water for example takes temperatures above 212 degrees to superheat and temperatures below 32 degrees to sub cool.


What amount of superheat is recommended for R-22?

Superheat depends on the type of metering device you are using in the equipment as well as the current state of the load. With a fixed orifice, the superheat will be high, about 20 to 30 degrees when the box is warm, down around 10-15 when the box is cold. With a txv, the superheat should be constant, normally between 10-15 degrees. It is best to check the superheat at the outlet of the evaporator. this will ensure that the compressor does not slug with liquid refrigerant.


What is the meaning of overheat?

To heat to excess; to superheat.