You can test for voltage in a circuit with the help of voltmeter or multimeter (analog or digital (DMM) ). Vikas Pratap Singh NIT Kurukshetra vps3361@gmail.com
generally open circuit test is performed on the low voltage side.....not on high voltage side.... becuase on low voltage side, we can apply that low voltage very easily ( i.e with a less amount of source is required)... whereas on high voltage side, we need a large power source in order to apply full voltage... in short circuit test, we will test on high voltage side by keeping Low voltage side being short circuit.because high voltage side needs less current source than low voltage side....
I assume "tension" in this question should be replaced with "voltage". Short circuit tests are often performed from the lower voltage side of the transformer, since a lower voltage source is then required to perform the test. Often times the test lab may not have a source that can output a high enough voltage to perform from the high voltage winding.
An open-circuit test is done with the transformer running at its rated voltage but with no load. This measures the power lost in the magnetic core. (IR Losses) A short-circuit test is done with the transformer running at its full rated current in all windings but at a low voltage. The secondary is shorted and the primary voltage is adjusted to give the rated current. This measures the power lost in the copper windings. (Copper losses)
Increase the resistance (ohms) Decrease the voltage (Volts)
Yes, if it is a series circuit. In an ideal parallel circuit, there is equal voltage in each leg. In a real circuit, results may vary if there is voltage loss in the wiring.
Use a multimeter and test if there is a voltage drop or current over the wire circuit.
in the short circuit test we applied supply voltage on L.V side and short circuit the H.V side and connect the ammeter in H.V circuit to measure the short circuit current. with the help of s.c test we measure the copper losses in the transformers.
open circuit & short circuit test, insulation resistance test, turns ratio, efficiency, if it is oil cooled then breakdown voltage of oil, voltage regulation and definitely visual inpection...
A multimeter.
The maximum voltage that the electronic parts can conduct without breaking.
it just happens that way retard
A multimeter.
Do a voltage test. Start at one end of the circuit and progress along device by device. If there is voltage on the down stream side of the device move on to the next. If there is no voltage on the down stream side of the device then go up stream of the device. If you have voltage there then the current device that you are at is the problem causing an open or broken circuit.
generally open circuit test is performed on the low voltage side.....not on high voltage side.... becuase on low voltage side, we can apply that low voltage very easily ( i.e with a less amount of source is required)... whereas on high voltage side, we need a large power source in order to apply full voltage... in short circuit test, we will test on high voltage side by keeping Low voltage side being short circuit.because high voltage side needs less current source than low voltage side....
In Short circuit test High Voltage side is feeded with 2-5% of the High Voltage rating to circulate approximately full load current in low voltage winding by short circuiting it. Low voltage is generally short circuited to facilitate measurements because it is more difficult to measure the quantities at high voltages.
A voltage test meter is used to measure voltage potentials in a circuit.
I assume "tension" in this question should be replaced with "voltage". Short circuit tests are often performed from the lower voltage side of the transformer, since a lower voltage source is then required to perform the test. Often times the test lab may not have a source that can output a high enough voltage to perform from the high voltage winding.