do a continuity test between the neutral and the metal enclosure of the equipment containing the neutral. infinity reading [ open line ] indicates floating neutral. Steve sorensen jr
make separate earth pits far from the electrical system earth pits and test to have low resistivity then connect the system or tower.
If the test shows that there is a continuity between the phase leg and the neutral with no load connected, then that circuit should not be energized. If the circuit was energized then the fuse or breaker protecting that leg will trip the circuit open.
Make sure there is no voltage measured between line of secondary and neutral of primary. I.e. neutral of primary and secondary are not connected by any means.
A 'polarity test', as it applies to a switch, is performed to confirm that the switch is located in the line conductor and not in the neutral conductor.
Take 240V Lamp first check the voltage at Phase w.r.t neutral if lamp glows it means present voltage is OK now check the voltage w.r.t earth i.e. between phase & Earth point then lamp will glow. Now check between Neutral & Earthing Lamp should not glow. If these conditions are fulfill then your Earthing is OK.
how do test a variable resistor
its easier to undo the motor and test that if that isn't working then it will more than likely be the resistor
To test the blower motor resistor, unplug the resistor connector. Each blower motor switch input terminal on the resistor must have continuity to the resistor output terminal, which is connected to the circuit going to the blower motor. If the blower motor resistor continuity does not check OK, replace the faulty resistor.You need a multimeter to test the resistor block and there should be continuity between all terminals.
Meggar test or continuity test of winding with respect to body / earth will tell you the truth.
ohm the resister with a multimeter
If you are missing the lower speeds but still have high speed, the resistor is bad.
Remove and test with an ohmmeter Explain how to test with an ohmmeter?
Earthing is necessary for equipment safety and for human safety.Answer for USA, Canada and countries running a 60 Hz supply service.There are two types of earthing, they are:Plate earthing andPipe earthing.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.
Switch it.
you gotta ask curtis
Resistor is behind glove box (Push inward on glove box hinges to release) Pull out both sets of wires from resistor plug-in. (push release clips on both sets to pull out wires) Remove 2 small screws holding the resistor. Remove the resistor ( test the wire that has the small diode ) with a multimeter to ensure it has power on both sides of the diode. If there is current on your multmeter the resistor is okay...... if no current is present on your multimeter the diode is burnt and the resistor unit needs replacement.