The voltage 277 volts is a three phase line to neutral voltage of a 480 volt system. What is needed for the protection of the transformer is a two pole breaker from the 480 volt CDP (Central Distribution Panel). The breaker will be sized to the KVA of the transformer. The wire will be sized to the breaker plus 25%. The electrical code requires that on motor and transformer feeders, they be sized to 125% of the total current capacity of the equipment.
Not unless it is rated for that voltage. You can likely find a step down transformer from 277 volt sto 120 volts.
It depends on what 277 volt device you are trying to connect.
Operating at half the required voltage, the lamp will not operate at full capacity if it comes on at all.
1You could get 220-240V from using the two live ["hot"] wires rather than one live and one neutral. 2Tim, Industrial control transformers are available to get 120 volts from 277 volt systems. If you feed one of these with 120 volts to the secondary coil, it will put out 277 volt from the primary. However, these are rare and are not cheap. If you are trying to use surplus 277 volt fluorescent lights on a 120 volt system, it would be cheaper to replace the ballasts in the fixtures. Another approach would be to use an autotransformer with a 240 volt primary and a 32 volt secondary. If you feed it with 240 volt and wire it to boost +32 volts that will give you 272 volt which should run the lights. But again, you are looking at $60 - $100 for one circuit of lights. 3If you have access to three phase power..... Phase to ground on a 480v 3 phase system is 277v.
no ----------------------------------------------------------------------------------- Stepdown transformer. More expensive than buying the correct light fixture. Y-THINK-Y
i think you just have to change the breaker from a 277 to a 120. 277 breakers are usually a 2 pole breaker and 120 is a single pole breaker. NO. 277v is not two poles, it is one pole, one single pole breaker in a 480 volt 3 phase system (typically). If you want 120 volts from a 277 volt source you need a step down transformer 277 volt to 120 volt , or 480/277 to 120/208 .
Not unless it is rated for that voltage. You can likely find a step down transformer from 277 volt sto 120 volts.
A 277 volt lighting fixture is one that is usually used in an industrial application. The reason for this is the voltage rating. A voltage potential of 277 volts is the voltage to neutral (ground) of a three phase four wire 480 volt distribution system. 480 volts / 1.73 = 277 volts. Rather than having to add a transformer to the system to provide 120 volts for lighting, manufactures produced a ballast for fluorescent fixtures that operates on the 227 volt potential.
The voltage of 277 is the wye connection of a 480 volt three phase supply. The only way to reduce 277 to 120 volts is with a step down transformer.
It depends on what 277 volt device you are trying to connect.
no
Yes.
no
There in no quick and inexpensive way of doing this conversion. A transformer would have to be used and this type of winding is not common. 277 volts is the wye voltage of a three phase 480 volt system.
Operating at half the required voltage, the lamp will not operate at full capacity if it comes on at all.
NO! a 120-277 electronic ballast requires one "hot" wire and a neutral from either a 110V or 277V supply. If you supply it with two "hot" wires from a 208 V supply, it will instantly burn up.Yes. A ballast with a specification range of 120 volt to 277 volt will work on 208 volt. These ballast use intelligent voltage sensing technology and it does not matter if the source is a hot and neutral or two (2) hots. Don't believe it? Call a ballast manufacturer instead of giving incorrect answers.
For 120/208v 3 phase system: black, red, blue, white For 277/480v 3 phase system: brown, orange, yellow, gray Phase colors are not stipulated in the code book for the United States. The above colors are used by convention. Neutrals, however, must be white or gray.