answersLogoWhite

0


Want this question answered?

Be notified when an answer is posted

Add your answer:

Earn +20 pts
Q: How does bi Metal fan switch operates the blower?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

I think I need a new blower relay for my 1993 olds delta 88 royal the heater fan will cut out at times and then come back on once it's on I do have all speeds working do you think it's the relay?

The blower relay only operates the high speed function. The blower speed resistor operates all the lower speeds. I would suspect the blower speed switch is at fault. Examine the blower speed switch and the plastic electrical plug that plugs into the switch, you may see the plug has melted.


How do you change a blower switch on a 2001 Grand Prix?

it is probley not the blower switch. if your fan runs on 3,4 and 5 it is your blower motor resister.


99 Acura TL Blower fan do not work?

Check your radiator fan switch and your fan switch coolant sensor .


Electric furnace fan blower will not shot off?

Bad low limit switch,fan switch.


What operates the radiator cooling fan in a 1988 Toyota Corrolla?

the fan switch.


Why is the fan switch not working on your 1999 grand prix?

Bad fan switch Bad fuse Bad resistor pack on blower motor Bad blower motor


Does blower motor relay make fan run?

A typical blower motor relay only operates the high speed function.


Replace switch that control fan speed for vent in Chevy silverado?

Change blower fan control switch in the dash


1993 Chevy pu you have no low or med blower motor speeds you have high only you have checked all the fan speed relays resistor fan switch and blower motor all ok What to do next?

Resistor pack on blower motor? Fan switch? Low speed relay?


I have a 2000 Nissan sentra. My blower fan switch is numbered 1 to 4 and when i turn it on it only works on number 4.?

Blower resistor switch


What can be wrong with a 1992 Geo Metro that when you turn on the fan blower switch no air blowes out?

You have a bad blower motor. i have seen a lot of the switches go bad turn on the fan and try pushing down on the fan switch and see if the fan comes on Just to add a liitle to this reply generally if it is your fan switch not all of the speeds burn out at the same time so try turning the switch to every position if any of them turn on ur fan than its just the switch if none of the fan speeds work than it is your blower motor.


Why do my fan blower stay on all the time in a 2002 BMW 5 series?

bad blower switch located behind blower control.