A potential relay operates on the voltage potential created by the induced voltage in the starting winding of the motor. It is an electromagnetic switch whose coil is wired directly in to the motor circuit. When power is applied to the circuit, the motor starts . As the motor attains its running speed the start winding acts as an auto generator and the voltage potential produced energizes the relay coil which cuts out the start capacitor and the start winding . The start winding still acts as an auto generator , however , and continues to produce enough power to keep the relay energized.
The voltage for a potential relay will depend on the circuit that the relay is installed in. The relay can be made for low voltages (5v) to higher voltages (440.)
The electrical control panel for a refrigeration unit using single or three phase power. The control portion has an oil pressure safety switch, defrost timer, temperature controls and perhaps a refrigerant pressure control in conjunction with the normal internal overload circuit breakers for the compressor. After operation of the refrigeration unit for a period of time, a defrost control device cuts off the compressor and turns on the electric defrost heaters. As the evaporator coils are defrosted, defrost thermostats open the defrost heater supply circuits. When the current sensing relay senses that all the defrost heaters have been shut off via the defrost thermostats, a time delay relay will return the refrigeration unit to the normal refrigeration cycle. The same current sensing relay will prevent false triggering by the oil pressure safety switch if the compressor's internal overload circuit breaker opens
Both Current and Potential Transformers are used for relays according to the working of relay.
you dont waste to much energy but it still works fine.
A potential transformer steps the high voltage down to a level of 120 V to measure them safely and easily.
The refrigeration units take their power from the locomotive.
current relay are using for over current low state & high state.but potential relay are related to voltage.
The voltage for a potential relay will depend on the circuit that the relay is installed in. The relay can be made for low voltages (5v) to higher voltages (440.)
An evaporator in a refrigeration system works by passing warm air over it's coils.
Common wire of the potential relay goes to the compressor contactor. (5) Start wire of the potential relay goes to compressor run capacitor. (2) Run wire of the potential relay goes to the start capacitor. (1)
Potential or voltage relay is used for assisting the motor to start. Its operation is based on the increase in back-electro-motive force (back-EMF).
Bypass the relay and if the pump works the relay is bad.
Refrigeration works by cooling items to a point too low for certain bacteria to thrive.
Potential energy.
If the pump is running the relay is good.
put in a new relay... if the window works it was a bad relay
If neither side works, the Flasher Relay is defective. Replace it.If neither side works, the Flasher Relay is defective. Replace it.