Reactive power is well known as that component which is shunted back and forth from the source to the load over the AC cycle. However, this does not mean the system has no reactive power losses. In fact they would be quite high. Loss is always measured with respect to load and not the source. When we term it reactive power loss, it is not the amount of power taken away from the source and not returned. That way, there would absolutely be no reactive loss at all because all the energy stored in the reactive elements are anyway returned. The idea is after all to provide the power to the load. So, the loss represents the amount of power unable to reach the load. The power lines are not purely resistive. They comprise considerable level of reactive elements especially line inductance.

Now, the active power which actually runs the load is never a separate entity. It co-exists with reactive power because the reactive (more so inductive) components of the load need to be energized in order to power the load. Reactive power loss is thus that amount of power which is deficient or 'not supplied' to the storage (reactive) elements of the load because of the reactive elements on the line. Thus the loss is always to be visualized in terms of load. That is why the complete return of reactive power to the source in the negative cycle has got nothing to do with loss understanding actually.

Hope this helps!

User Avatar

Wiki User

12y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How reactive power contributes to additional losses?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

Why reactive power is named as reactive?

Actually reactive power is a power which flows in between load to source which is a reactive action of the power given from source to load.the given power to load will not be utilised fully.some power will be oscillating from load to source.this is called reactive power.


What happens to reactive power in a circuit that has both inductance and capacitance?

Inductors are considered to be a load for reactive power, meaning that they will draw reactive power from the system. Capacitors are considered to be sourced of reactive power, they feed reactive power into the system. If you have a circuit that is at unity (balanced with inductors and capacitors) no reactive power will be drawn from the source. You will have unity power factor. If your circuit is more inductive than capacitive it will be drawing reactive power from the source. The opposite is also true for capacitors.


Which excitation synchronous motor drawn reactive power?

Hi, Under excitation - inductive reactive power Over excitation - Capacitive reactive power.


Is reactive power greater than true power?

Use a wattmeter, as it only reads 'real power' of your load. Use an ammeter and a voltmeter, and the product of the two readings will give you 'apparent power' of your load. Since apparent power is the vector sum of real power and reactive power, use the following equation to find the reactive power of your load: (reactive power)2 = (apparent power)2 - (real power)2


What are advantages of reactive power?

Real power is power that is used to do work. This is the power a light bulb uses to glow. Reactive power is power that is stored in one part of the AC voltage wave, and released in another. This causes the power to appear as a phase shift, and is generally caused by inductive or capactive loads. With regard to the power system, you can also get reactive power flowing due to unequal source voltages. Under these conditions, the apparent impedance of one source to the other will appear reactive/inductive, resulting in reactive power flow.

Related questions

How reactive power drives active power?

reactive power depends on motor winding losses and the reason for increasing of temperature. At running condition the motor power reduces by copper loss.


How real losses increase with increase of reactive power?

As far as the load is concerned, they don't. But, as far as the supply lines are concerned, they have to cater for an increase in load current and, therefore, increased line losses, if the reactive power of the load increases.


Which line requires compensation?

Basically an AC transmission line require compensation in terms of reactive power. To push the active power across a transmission line certain amount of reactive power is necessary. In AC transmission line reactive power is generated and consumed. Generator is responsible for the production of reactive and active power both. Than this reactive power is consumed by the load and transmission line. Additional reactive power s supplied by the capacitor. This extra power supplied by the capacitor is termed as reactive power compensation. Requirement of this reactive power is there because reactive power is necessary to maintain the voltage stability.


Why reactive power is important?

it is important b'cos,it discribes the losses of power.For caliberation we are giving more prieority to the loss in the component or a device


Why reactive power is named as reactive?

Actually reactive power is a power which flows in between load to source which is a reactive action of the power given from source to load.the given power to load will not be utilised fully.some power will be oscillating from load to source.this is called reactive power.


Why the power factor of a transformer is poor at no load?

The inductance of the transformer is much higher than the resistance of the transformer, resulting in very low real power losses (in watts), but some reactive power (vars).


Why wattmeter measure the reactive power?

A watt meter will measure active power, not reactive power.


What happens to reactive power in a circuit that has both inductance and capacitance?

Inductors are considered to be a load for reactive power, meaning that they will draw reactive power from the system. Capacitors are considered to be sourced of reactive power, they feed reactive power into the system. If you have a circuit that is at unity (balanced with inductors and capacitors) no reactive power will be drawn from the source. You will have unity power factor. If your circuit is more inductive than capacitive it will be drawing reactive power from the source. The opposite is also true for capacitors.


How can you reduce reactive power?

If, for example, the reactive power of a load is due to its inductance, then installing a capacitor in parallel with the load will reduce the overall reactive power.


Which excitation synchronous motor drawn reactive power?

Hi, Under excitation - inductive reactive power Over excitation - Capacitive reactive power.


Is that the reactive power is a combination of both reactive power and imaginary power?

No. It is apparent power (expressed in volt amperes) that is the combination (vector sum) of true power (expressed in watts) and reactive power (expressed in reactive volt amperes). 'Imaginary power' is simply another name for 'reactive power' -where 'imaginary' is simply mathematicians-speak for 'quadrature' or 'right angles'.


Is reactive power a vector or scalar?

I am not sure what exactly you mean by "reactive power" (I guess you mean electrical reactive power), but power is the ratio of energy for a period of time. So that makes power (and reactive power as well) a scalar, since you can describe it with only one number. The fact that electrical reactive power is drawn on a XY plane, should not confuse you.