Continue Learning about Engineering

What is meaning ring main unit RMU and application?

A ring-main unit is a piece of switchgear used on high-voltage distribution ring-main systems (e.g. in the UK at 11 kV). Essentially, it's three switches incorporated into one device used to connect a transformer to a high-voltage ring main. It allows the transformer to be connected/disconnected to the ring main and it also allows the ring main to be 'broken'. Each of the switches has three positions: open, closed, or earthed (grounded); the earth position allows the transformer or either (or both) halves of the ring main to be earthed when maintenance is required.


What is RMU?

An 'RMU' is a 'ring-main unit', a type of switchgear used to connect distribution transformers to an underground, secondary-distribution (11 kV in the UK), cable ring-main system. It enables the transformer to be disconnected from the ring main, and it also enables the ring main itself to be 'split' where the RMU is installed. Each of the three switches within an RMU usually incorporates an 'earth' (ground) position, which will enable either the transformer itself, or the ring main to be earthed for safety reasons before any maintenance work can proceed.


What is ring power distribution?

In ring power distribution power is distributed in a ring where each point gets power from both the directions. The main advantage of a ring system is the reliability is high because if one link is broken power can be still be delivered from the other link.


What is meaning of ring main unit?

A standard piece of switchgear in distribution systems comprising of switches for switching power cable rings and of switches in series with fuses for the protection of distrbution transformers. RMU: Ring Main Unit. RMU used for H.T.side. RMU is having 3no.s of switches(Circuit Breakers or Isolators or LBS), it is used for two inputs with mechanical or electrical interlock and one outgoing to the load. Either one input with two outgoings. RMU used for redundancy feeder's purpose. Ring main unit is used in a secondary distribution system. It is basically used for an uninterrupted power supply. Alongside, it also protects your secondary side transformer from the occasional transient currents. Depending on your applications and loading conditons you can use a swicth fuse combination or a circuit breaker to protect the transformer. This transformer connected to the switch fuse/ circuit breaker is called your T off. In a common arrangement you have Load break swicthes on both the sides of your T off. Ring main Units come in standard ratings of 11/22/33 kV, 630/1250 A, 21 KA/3 secs.


What is a ring main circuit in the UK and the Irish Republic?

A ring main circuit for example is: key: circuit breaker=0 cable=---- socket=[] bends in cable=/ and \ Using the key this is a demonatration. 0---[]-----[]-------[]------[]---[]---\ \---[]-----[]-----[]----[]-------[]---/ Just imagine that there is only 1 circuit breaker in that circuit, both ends of the ring main should link up to that 1 breaker. A radial circuit consists of just 1 cable going to the circuit breaker with sockets on the cable but there is no return path on a radial. A ring main is just like a big circle with 2 ends of cable and sockets around the circle=both ends of the cable linking to the circuit breaker.

Related questions

Why does your hayward chlorine feeder leak?

You need to replace the "O" ring inside the lid of the feeder.


What is Ring Protection in SDH?

Ring protection is a system where multiplexers are connected in a ring topology. If a single span fails traffic switches around the other side of the ring.


How do you Extend a ring main?

What is a ring main?


Can you with your boyfriend?

nope, not with out protection or when you have a promise ring!


What is Uranus main ring?

The Mab Ring.


When was Thames Water Ring Main created?

Thames Water Ring Main was created in 1993.


Where is the turn signal relay on a 1981 sportster xlh iron-head?

The relay is located inside the headlight housing. Loosen the screw on the trim ring around the headlight, pull the trim ring and then pull the headlight. The flasher relay will be either rectangular or round with two prongs. Good luck


What is a medium voltage ring main?

how, in simple terms, would you describe a ring main (Specifically medium voltage)


List four devices that you might connect to a domestic ring main?

how are devices connected to a domestic ring main


What is meaning ring main unit RMU and application?

A ring-main unit is a piece of switchgear used on high-voltage distribution ring-main systems (e.g. in the UK at 11 kV). Essentially, it's three switches incorporated into one device used to connect a transformer to a high-voltage ring main. It allows the transformer to be connected/disconnected to the ring main and it also allows the ring main to be 'broken'. Each of the switches has three positions: open, closed, or earthed (grounded); the earth position allows the transformer or either (or both) halves of the ring main to be earthed when maintenance is required.


If you take the nuva ring out on a Wednesday are you still protected by Sunday?

If you used the ring correctly and consistently in the three weeks before the ring-free week, you have no decrease in protection during the ring-free week.


What is the use of ring main unit?

ring main unit is distributing the power supply to meter cubicalAnswerA ring-main unit (rmu) is a piece of switchgear that is used to connect a transformer's primary winding to a high-voltage ring main. It consists of three load-breaking switches, each with three positions: 'on', 'off', and 'earth'. They enable the transformer to be connected/disconnected to the ring; the ring to be 'broken'; or the transformer to be connected to either half of the broken ring. The 'earth' positions allow the transformer's secondary to be earthed, or either half of the (broken) ring to be earthed.