Want this question answered?
An auxiliary relay is a back-up relay in case the primary relay fails.
The 59 relay is an overvoltage relay. The 59N relay is an overvoltage relay for the neutral circuit. Check neutral and make sure the system is properly balanced.
A relay in power plants comprises three components namely voltage relay, thermal relay and current relay. It is used to power up an industrial equipment.
You need a double pole relay, that is a relay with 4 connection places. [screws, etc.]. Place your 2 hot wires on the screws marked line, makes no difference which wire on which screw. The 2 wires being energized by the relay action go on the load screws of the relay. Square D makes a good quiet relay. Also make sure you buy a relay large enough to carry the load. The amperage on the device the relay is to control will determine the relay size. See View Discussion for more information.
picture of the fan relay for 1993 mercury topaz
OFFSET IMPEDANCE RELAYOffset impedance relay is also known under names ADMITTANCE RELAY or MHO RELAY
because the distance is propotional to the impedance of the line ,so the operation of the impedance relay comes into picture when the impedance seen by the relay is less than the pre-setting value.When a fault occurs ,the current increases to a high value and so the Impedence decreases and the relay actuates
Impedance relays are used whenever over-current relays do not provide adequate protection. They function even if the short circuit current is relatively low. The speed of operation is independent of current magnitude. Impedance relays monitor the impedance between the relay location and the fault. If the impedance falls within the relay setting, the relay will operate. The basic construction for impedance relays on which the principle of operation is easily explained is the balanced beam.
Instantaneous over current relay, which operates very fast with no intentional time delay and the operating time of these relay can be as low as 0.01sec . These relay operates only when the impedance between the relay and the source zsis very small compared to the impedance to the impedance of the protected section zl .
The distance relay trips when a fault occurs at a distant or a remote place in the electric transmission line. There is a mechanism based on the impedance calculation of the distance of the transmission line after which it is accurately known where the fault has taken place. Thus the distance protective relay can trip the circuit & prevent the fault to be carried further and also can indicate the location of the fault.
where is the transmission relay on a 1999 Honda Accord
Well any type of relay protection is extremely complicated any many people will spend their whole career learning about protection and control. But a distance relay essentialy looks at the impedance of the circuit to be protected. When a fault occurs the impedance of the circuit will change. It then calculates this new impedance to determine where the fault has occurred. By knowing where the fault is it can trip appropriate CB's to isolate the faulted section.
The most common form of protection on high voltage transmission systems is distance relay protection. Power lines have set impedance per kilometre and using this value and comparing voltage and current the distance to a fault can be determined. The ANSI standard device number for a distance relay is 21
there is a computer for the automatic transmission but i did not think there was a relay. I would have to double check.
distance relay..........
high impedance circit provides a varistor unit which has stabilising resistor which ll protect the relay from being operating for maloperations like through fault, CT faults whereas this varistor unit is provided internally in an numerical relay where the CT of class 5P can be used.
Ohm relay.......